Age Modulates Physiological Responses during Fan Use under Extreme Heat and Humidity

被引:28
|
作者
Gagnon, Daniel [1 ,2 ,3 ,4 ]
Romero, Steven A. [1 ,2 ]
Cramer, Matthew N. [1 ,2 ]
Kouda, Ken [1 ,2 ,5 ]
Poh, Paula Y. S. [1 ,2 ]
Ngo, Hai [1 ,2 ]
Jay, Ollie [6 ]
Crandall, Craig G. [1 ,2 ]
机构
[1] Texas Hlth Presbyterian Hosp Dallas, Inst Exercise & Environm Med, 7232 Greenville Ave, Dallas, TX 75231 USA
[2] Univ Texas Southwestern Med Ctr Dallas, Dallas, TX 75390 USA
[3] Montreal Heart Inst, Res Ctr, Cardiovasc Prevent & Rehabil Ctr, Montreal, PQ, Canada
[4] Univ Montreal, Dept Pharmacol & Physiol, Fac Med, Montreal, PQ, Canada
[5] Wakayama Med Univ, Wakayama, Japan
[6] Univ Sydney, Fac Hlth Sci, Lidcombe, Australia
来源
基金
加拿大自然科学与工程研究理事会; 美国国家卫生研究院;
关键词
CARDIOVASCULAR; CORE TEMPERATURE; HEAT WAVE; HEART RATE; SWEAT; VASODILATION; CLIMATE-CHANGE; RISK-FACTORS; HUMAN HEALTH; BLOOD-FLOW; WAVE; DEATH; SKIN; FOREARM;
D O I
10.1249/MSS.0000000000001348
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose: We examined the effect of electric fan use on cardiovascular and thermoregulatory responses of nine young (26 +/- 3 yr) and nine aged (68 +/- 4 yr) adults exposed to extreme heat and humidity. Methods: While resting at a temperature of 42 degrees C, relative humidity increased from 30% to 70% in 2% increments every 5 min. On randomized days, the protocol was repeated without or with fan use. HR, core (T-core) and mean skin (T-sk) temperatures were measured continuously. Whole-body sweat loss was measured from changes in nude body weight. Other measures of cardiovascular (cardiac output), thermoregulatory (local cutaneous and forearm vascular conductance, local sweat rate), and perceptual (thermal and thirst sensations) responses were also examined. Results: When averaged over the entire protocol, fan use resulted in a small reduction of HR (-2 bpm, 95% confidence interval [CI], -8 to 3), and slightly greater T-core (+0.05 degrees C; 95% CI, -0.13 to 0.23) and T-sk (+ 0.03 degrees C; 95% CI, -0.36 to 0.42) in young adults. In contrast, fan use resulted in greater HR (+ 5 bpm; 95% CI, 0-10), T-core (+0.20 degrees C; 95% CI, 0.00-0.41), and T-sk (+ 0.47 degrees C; 95% CI, 0.18-0.76) in aged adults. A greater whole-body sweat loss during fan use was observed in young (+ 0.2 kg; 95% CI, -0.2 to 0.6) but not aged (0.0 kg; 95% CI, -0.2 to 0.2) adults. Greater local sweat rate and cutaneous vascular conductance were observed with fan use in aged adults. Other measures of cardiovascular, thermoregulatory, and perceptual responses were unaffected by fan use in both groups. Conclusions: During extreme heat and humidity, fan use elevates physiological strain in aged, but not young, adults.
引用
收藏
页码:2333 / 2342
页数:10
相关论文
共 50 条
  • [1] The biophysical and physiological basis for mitigated elevations in heart rate with electric fan use in extreme heat and humidity
    Ravanelli, Nicholas M.
    Gagnon, Daniel
    Hodder, Simon G.
    Havenith, George
    Jay, Ollie
    INTERNATIONAL JOURNAL OF BIOMETEOROLOGY, 2017, 61 (02) : 313 - 323
  • [2] The biophysical and physiological basis for mitigated elevations in heart rate with electric fan use in extreme heat and humidity
    Nicholas M. Ravanelli
    Daniel Gagnon
    Simon G. Hodder
    George Havenith
    Ollie Jay
    International Journal of Biometeorology, 2017, 61 : 313 - 323
  • [3] The Impact Of Hypohydration On The Efficacy Of Electric Fan Use For Reducing Physiological Heat Strain During A Passive Heat Extreme Simulation
    Hospers, Lily T.
    Graham, Connor
    Mavros, Yorgi
    Jay, Ollie
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2023, 55 (09) : 689 - 689
  • [4] SELECTED HUMAN PHYSIOLOGICAL RESPONSES DURING EXTREME HEAT: THE BADWATER ULTRAMARATHON
    Brown, Jacqueline S.
    Connolly, Declan A.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2015, 29 (06) : 1729 - 1736
  • [5] Cardiac and Thermal Strain of Elderly Adults Exposed to Extreme Heat and Humidity With and Without Electric Fan Use
    Gagnon, Daniel
    Romero, Steven A.
    Cramer, Matthew N.
    Jay, Ollie
    Crandall, Craig G.
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2016, 316 (09): : 989 - 991
  • [6] The impacts of plant physiological responses to rising CO2 on humidity-based extreme heat
    Ashley E. Cornish
    Gabriel J. Kooperman
    Andrew J. Grundstein
    Christopher B. Skinner
    Abigail L. S. Swann
    npj Climate and Atmospheric Science, 8 (1)
  • [7] Physiological responses of adults with coronary artery disease during extreme heat exposure
    Bartlett, Audrey-Ann
    PHYSIOLOGY, 2023, 38
  • [8] Physiological responses of tom turkeys to temperature and humidity change with age
    BrownBrandl, TM
    Beck, MM
    Schulte, DD
    Parkhurst, AM
    DeShazer, JA
    JOURNAL OF THERMAL BIOLOGY, 1997, 22 (01) : 43 - 52
  • [9] Impact of Fan Use on Physical Work Capacity in Extreme Heat
    Smallcombe, James W.
    Foster, Josh
    Hodder, Simon
    Jay, Ollie
    Flouris, Andreas D.
    Griggs, Katy
    Dorman, Lucy
    Havenith, George
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2019, 51 (06): : 15 - 15
  • [10] A case report on the physiological responses to extreme heat during Sicily's July 2023 heatwave
    Filingeri, Davide
    Valenza, Alessandro
    Ficarra, Salvatore
    Filingeri, Victoria
    Worsley, Peter R.
    Bianco, Antonino
    PHYSIOLOGICAL REPORTS, 2024, 12 (11):