Wavelength-encoded multi-channel spectral domain optical coherence tomography (SD-OCT) for spatiotemporally resolved imaging

被引:0
|
作者
Mekonnen, Taye [1 ]
Kourmatzis, Agisilaos [2 ]
Cheng, Shaokoon [1 ]
机构
[1] Macquarie Univ, Sch Engn, Sydney, NSW 2109, Australia
[2] Univ Sydney, Sch Aerosp Mech & Mechatron Engn, Sydney, NSW 2006, Australia
关键词
optical coherence tomography; interferometer; multi-channel; spectral decomposition; CONFIGURATION; LAYERS; SCANS;
D O I
10.1088/1361-6501/ab85d6
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In conventional spectral domain optical coherence tomography (SD-OCT), a beam is focused to one spot on the surface of the sample to acquire depth information beneath that spot. Adjacent spots are serially scanned to obtain a tomographic image of the sample; thus, available OCT techniques can take significant time to scan large objects. This paper illustrates an SD-OCT system involving spectral-slicing of a broadband spectrum to enable the simultaneous acquisition from multiple lateral positions of the sample. Using a wavelength encoding of spatial information, where each lateral location is associated with a specific portion of a source spectrum, multiple lateral spots are interrogated concurrently to improve the imaging speed of SD-OCT. A triple-channel SD-OCT system was devised using a broadband source of centre wavelength 840 nm and full width half maximum (FWHM) bandwidth of 50 nm. Both sample and reference arm beams were split into three channels using two dichroic splitters of 50% cut-on wavelength at 825 nm and 848 nm, resulting in a FWHM spectral distribution of 13.5 nm, 19 nm and 17.5 nm in the three channels, respectively. The imaging performance of the technique was demonstrated by concurrently acquiring tomographic images of a 3D-printed phantom. Despite the relative drop in the per-channel axial resolution and depth sensitivity, this new approach presents a straightforward way of interrogating a sample simultaneously in multiple locations, provides the additional advantage of allowing different delay lines for each spectral section and offers the potential of such a system to be used in a wide range of applications that demand a small product foot print.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Longitudinal reproducibility of spectral domain optical coherence tomography (SD-OCT) in children with stable glaucoma and physiological cupping
    Xu, Limin
    El-Dairi, Mays
    Silverstein, Evan
    Freedman, Sharon
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [32] Enhanced spectral-domain optical coherence tomography (SD-OCT) using in situ ultrasonic virtual tunable optical waveguides
    Karimi, Yasin
    Yang, Hang
    Liu, Junze
    Park, B. Hyle
    Chamanzar, Maysamreza
    OPTICS EXPRESS, 2022, 30 (19): : 34256 - 34275
  • [33] Analysis of macular ganglion cell complex (GCC) with spectral-domain optical coherence tomography (SD-OCT) in glaucoma
    Renard, J. -P.
    Fenolland, J. -R.
    El Chehab, H.
    Francoz, M.
    Marill, A. -M.
    Messaoudi, R.
    Delbarre, M.
    Marechal, M.
    Michel, S.
    Giraud, J. -M.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2013, 36 (04): : 299 - 309
  • [34] SCREENING OF GLAUCOMA USING SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY (SD-OCT) IN AN ELDERLY POPULATION: THE ALIENOR STUDY
    Schweitzer, Cedric
    Le Goff, Melanie
    Korobelnik, Jean-Francois
    Rougier, Marie B.
    Delyfer, Marie-Noelle
    Dartigues, Jean-Francois
    DelCourt, Cecile
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [35] Subretinal thickening is a novel finding in Stargardt disease using Spectral Domain-Optical Coherence Tomography (SD-OCT)
    Light, Jacob G.
    Sun, Kai
    Handa, James T.
    Ebrahimi, Katayoon B.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [36] Nerve fiber layer thickness in a Latin American population using spectral domain optical coherence tomography (SD-OCT)
    Roca, Daniela
    Alejandra Cortes, Diana Alejandra
    Camila Plata, Maria
    Gutierrez, Sergio
    Rodriguez, Francisco J.
    Belalcazar-Rey, Sandra
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [37] Distribution of Gold Nanorods Monitored With Spectral-Domain Optical Coherence Tomography (SD-OCT) After Intravitreal Injection
    Gabriele, M. L.
    McKenna, K. C.
    Schuman, J. S.
    Ishikawa, H.
    Franks, J.
    Sun, M.
    Halfter, W.
    Kagemann, L.
    Wollstein, G.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [38] Using Asymmetry Analysis to Reduce Normal Variability of Spectral Domain Optical Coherence Tomography (SD-OCT) Macular Thickne
    Alluwimi, Muhammed
    Swanson, William
    Malinovsky, Victor
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [39] Assessment of retinal atrophy in mixed breed dogs using spectral domain optical coherence tomography (SD-OCT) and electroretinography
    Balicki, Ireneusz
    Szadkowski, Mateusz
    Balicka, Agnieszka
    Lew, Marcin
    Trbolova, Alexandra
    ACTA VETERINARIA HUNGARICA, 2024, 72 (02) : 80 - 98
  • [40] Assessment of the use of spectral domain optical coherence tomography (SD-OCT) for evaluation of the healthy and pathological cornea in dogs and cats
    Famose, Frank
    VETERINARY OPHTHALMOLOGY, 2014, 17 (01) : 12 - 22