Depolarization calibration and measurements using the CANDAC Rayleigh-Mie-Raman lidar at Eureka, Canada

被引:8
|
作者
McCullough, Emily M. [1 ,2 ]
Sica, Robert J. [1 ]
Drummond, James R. [2 ]
Nott, Graeme [2 ,4 ]
Perro, Christopher [2 ]
Thackray, Colin P. [2 ]
Hopper, Jason [2 ]
Doyle, Jonathan [2 ]
Duck, Thomas J. [2 ]
Walker, Kaley A. [3 ]
机构
[1] Univ Western Ontario, Dept Phys & Astron, 1151 Richmond St, London, ON N6A 3K7, Canada
[2] Dalhousie Univ, Dept Phys & Atmospher Sci, 6310 Coburg Rd,POB 15000, Halifax, NS B3H 4R2, Canada
[3] Univ Toronto, Dept Phys, 60 St George St, Toronto, ON M5S 1A7, Canada
[4] Cranfield Univ, Facil Airborne Atmospher Measurements, Bldg 146, Cranfield MK43 0AL, Beds, England
基金
加拿大自然科学与工程研究理事会;
关键词
MIXED-PHASE CLOUDS; POLARIZATION LIDAR; WATER CLOUDS; PARTICLE ORIENTATION; MULTIPLE-SCATTERING; CIRRUS CLOUDS; RATIO; BACKSCATTERING; AEROSOL; SYSTEM;
D O I
10.5194/amt-10-4253-2017
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
The Canadian Network for the Detection of Atmospheric Change (CANDAC) Rayleigh-Mie-Raman lidar (CRL) at Eureka, Nunavut, has measured tropospheric clouds, aerosols, and water vapour since 2007. In remote and meteorologically significant locations, such as the Canadian High Arctic, the ability to add new measurement capability to an existing well-tested facility is extremely valuable. In 2010, linear depolarization 532 nm measurement hardware was installed in the lidar's receiver. To minimize disruption in the existing lidar channels and to preserve their existing characterization so far as is possible, the depolarization hardware was placed near the end of the receiver cascade. The upstream optics already in place were not optimized for preserving the polarization of received light. Calibrations and Mueller matrix calculations are used to determine and mitigate the contribution of these upstream optics on the depolarization measurements. The results show that with appropriate calibration, indications of cloud particle phase (ice vs. water) through the use of the depolarization parameter are now possible to a precision of +/- 0.05 absolute uncertainty (<= 10% relative uncertainty) within clouds at time and altitude resolutions of 5 min and 37.5 m respectively, with higher precision and higher resolution possible in select cases. The uncertainty is somewhat larger outside of clouds at the same altitude, typically with absolute uncertainty <= 0.1. Monitoring changes in Arctic cloud composition, including particle phase, is essential for an improved understanding of the changing climate locally and globally.
引用
收藏
页码:4253 / 4277
页数:25
相关论文
共 50 条
  • [31] Detection of Tropospheric Aerosol Optical Properties by Rayleigh-Raman-Mie Lidar in the Northern Suburb of Nanjing
    Yu Liyao
    Cao Nianwen
    Shen Ji
    LASER & OPTOELECTRONICS PROGRESS, 2018, 55 (11)
  • [32] INDEPENDENT CALIBRATION OF WATER VAPOR RAMAN LIDAR BY USING ADDITIONAL ELASTIC MEASUREMENTS AT WATER VAPOR RAMAN WAVELENGTH
    Wu, Decheng
    Wang, Zhien
    Liu, Dong
    Xie, Chenbo
    Wang, Yingjian
    27TH INTERNATIONAL LASER RADAR CONFERENCE (ILRC 27), 2016, 119
  • [33] Polar stratospheric clouds observed by the ALOMAR Rayleigh/Mie/Raman lidar and the temperature field above Andoya
    Mehrtens, H
    vonCossart, G
    Hauchecorne, A
    Fierli, F
    13TH ESA SYMPOSIUM ON EUROPEAN ROCKET AND BALLOON PROGRAMMES AND RELATED RESEARCH, PROCEEDINGS: EUROPEAN SPACE AGENCY PROGRAMME ADVISORY COMMITTEE (PAC) ON THE SPECIAL PROJECT CONCERNING THE LAUNCHING OF SOUNDING ROCKETS, 1997, 397 : 163 - 167
  • [34] Portable stand-off Raman and Mie-Rayleigh lidar for cloud, aerosols, and chemical monitoring
    Sharma, SK
    Porter, JN
    Misra, AK
    Hubble, HW
    Menon, P
    LIDAR REMOTE SENSING FOR ENVIRONMENTAL MONITORING IV, 2003, 5154 : 1 - 14
  • [35] Tropospheric temperature measurements with the pure rotational Raman lidar technique using nonlinear calibration functions
    Zuev, Vladimir V.
    Gerasimov, Vladislav V.
    Pravdin, Vladimir L.
    Pavlinskiy, Aleksei V.
    Nakhtigalova, Daria P.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2017, 10 (01) : 315 - 332
  • [36] Atmospheric temperature profiling by joint Raman, Rayleigh and Fe Boltzmann lidar measurements
    Yu, Changming
    Yi, Fan
    JOURNAL OF ATMOSPHERIC AND SOLAR-TERRESTRIAL PHYSICS, 2008, 70 (10) : 1281 - 1288
  • [37] UV Rayleigh-Mie Raman lidar for simultaneous measurement of atmospheric temperature and relative humidity profiles in the troposphere
    Hua, DX
    Kobayashi, T
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2005, 44 (03): : 1287 - 1291
  • [38] Measurements for profiles of aerosol extinction coefficient, backscatter coefficient, and lidar ratio over Wuhan in China with Raman/Mie lidar
    Gong, Wei
    Zhang, Jinye
    Mao, Feiyue
    Li, Jun
    CHINESE OPTICS LETTERS, 2010, 8 (06) : 533 - 536
  • [39] UV rayleigh-mie raman lidar for simultaneous measurement of atmospheric temperature and relative humidity profiles in the troposphere
    Hua, Dengxin
    Kobayashi, Takao
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 2005, 44 (03): : 1287 - 1291
  • [40] Doppler wind lidar sensitivity and aerosol backscatter ratio measurement by combined Raman-Mie-Rayleigh scattering
    Wu Song-hua
    Chen Yang
    Song Zhilong
    Qin Shengguang
    Jin Lei
    Zhang Wei
    INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2011: LASER SENSING AND IMAGING AND BIOLOGICAL AND MEDICAL APPLICATIONS OF PHOTONICS SENSING AND IMAGING, 2011, 8192