Thermal neutron flux measurement using self-powered neutron detector (SPND) at out-core locations of TRIGA PUSPATI Reactor (RTP)

被引:2
|
作者
Ali, Nur Syazwani Mohd [1 ]
Hamzah, Khaidzir [1 ]
Idris, Faridah Mohamad [2 ]
Rabir, Mohamad Hairie [2 ]
机构
[1] Univ Teknol Malaysia, Dept Energy Engn, Fac Chem & Energy Engn, Johor Baharu 81310, Johor, Malaysia
[2] Agensi Nuklear Malaysia, Kajang 43000, Selangor, Malaysia
关键词
D O I
10.1088/1757-899X/298/1/012027
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The thermal neutron flux measurement has been conducted at the out-core location using self-powered neutron detectors (SPNDs). This work represents the first attempt to study SPNDs as neutron flux sensor for developing the fault detection system (FDS) focusing on neutron flux parameters. The study was conducted to test the reliability of the SPND's signal by measuring the neutron flux through the interaction between neutrons and emitter materials of the SPNDs. Three SPNDs were used to measure the flux at four different radial locations which located at the fission chamber cylinder, 10cm above graphite reflector, between graphite reflector and tank liner and fuel rack. The measurements were conducted at 750 kW reactor power. The outputs from SPNDs were collected through data acquisition system and were corrected to obtain the actual neutron flux due to delayed responses from SPNDs. The measurements showed that thermal neutron flux between fission chamber location near to the tank liner and fuel rack were between 5.18x10(11) nv to 8.45x10(9) nv. The average thermal neutron flux showed a good agreement with those from previous studies that has been made using simulation at the same core configuration at the nearest irradiation facilities with detector locations.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Evaluation for self-powered neutron detector used in sodium-cooled fast reactor
    Du, Sipeng
    Zhang, Qingmin
    Sang, Yaodong
    Liu, Shiyu
    ANNALS OF NUCLEAR ENERGY, 2025, 215
  • [32] Allowance for the burnup of a rhodium self-powered neutron detector in a VVER-1000 reactor
    A. Yu. Kurchenkov
    A. I. Kovel’
    V. A. Khvatov
    V. M. Chapaev
    Physics of Atomic Nuclei, 2013, 76 : 1586 - 1594
  • [33] Measurement method of in-core neutron and gamma-ray distributions with scintillator optical fibre detector and self-powered detector
    Mori, C
    Uritani, A
    Kakuta, T
    Katagiri, M
    Shikama, T
    Nakazawa, M
    Iguchi, T
    Kawarabayashi, J
    Kimura, I
    Kobayashi, H
    Hayashi, S
    BASIC STUDIES IN THE FIELD OF HIGH-TEMPERATURE ENGINEERING, 2002, : 161 - 166
  • [34] Simulation study of a rhodium self-powered neutron detector for irradiation of nuclear fuel and material reactor
    Zhou, Dianwei
    Li, Zhan
    Yang, Aixiang
    Xiao, Ren
    Guo, Zhiqi
    Zhang, Yuanji
    Zhu, Dingjun
    Shao, Jianxiong
    Chen, Ximeng
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1060
  • [35] USING A SELF-POWERED PLATINUM FLUX DETECTOR FOR IN-CORE MEASUREMENTS IN A BWR
    SEIFRITZ, W
    GEBURECK, P
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1973, 17 (NOV): : 449 - 450
  • [36] A TWIN SELF-POWERED NEUTRON DETECTOR FOR STEAM VELOCITY DETERMINATION IN A BOILING WATER-REACTOR
    KLEISS, EBJ
    VANDAM, H
    NUCLEAR TECHNOLOGY, 1981, 53 (02) : 250 - 256
  • [37] Self-powered neutron detector qualification for absolute on-line in-pile neutron flux measurements in BR2
    Vermeeren, L
    Wéber, M
    REACTOR DOSIMETRY IN THE 21ST CENTURY, 2003, : 219 - 225
  • [38] Self-Powered Neutron Detector Calibration Using a Large Vertical Irradiation Hole of HANARO
    Kim, Myong-Seop
    Park, Byung-Gun
    Kang, Gi-Doo
    ADVANCEMENTS IN NUCLEAR INSTRUMENTATION MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA 2017), 2018, 170
  • [39] Implantable self-powered detector for on-line determination of neutron flux in patients during NCT treatment
    Miller, ME
    Mariani, LE
    Gonçalves-Carralves, MLS
    Skumanic, M
    Thorp, SI
    APPLIED RADIATION AND ISOTOPES, 2004, 61 (05) : 1033 - 1037
  • [40] Influence of the gamma-ray fraction in the reactor radiation on the total signal of a self-powered neutron detector
    A. Yu. Kurchenkov
    A. S. Kulakov
    N. I. Alekseev
    A. E. Kalinushkin
    Physics of Atomic Nuclei, 2013, 76 : 1578 - 1585