Dosimetric verification of intensity-modulated fields

被引:142
|
作者
Wang, XH
Spirou, S
LoSasso, T
Stein, J
Chui, CS
Mohan, R
机构
[1] Department of Medical Physics, Mem. Sloan-Kettering Cancer Center, New York, NY 10021
关键词
3-D conformal radiotherapy; intensity modulation; dosimetry;
D O I
10.1118/1.597661
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The optimization of intensity distributions and the delivery of intensity-modulated treatments with dynamic multi-leaf collimators (MLC) offer important improvements to three-dimensional conformal radiotherapy. In this study, a nine-beam intensity-modulated prostate plan was generated using the inverse radiotherapy technique. The resulting fluence profiles were converted into dynamic MLC leaf motions as functions of monitor units. The leaf motion pattern data were then transferred to the MLC control computer and were used to guide the motions of the leaves during irradiation. To verify that the dose distribution predicted by the optimization and planning systems was actually delivered, a homogeneous polystyrene phantom was irradiated with each of the nine intensity-modulated beams incident normally on the phantom. For each exposure, a radiographic film was placed normal to the beam in the phantom to record the deposited dose. The films were calibrated and scanned to generate 2-D isodose distributions. The dose was also calculated by convolving the incident fluence pattern with pencil beams. The measured and calculated dose distributions were compared and found to have discrepancies in excess of 5% of the central axis dose. The source of discrepancies was suspected to be the rounded edges of the leaves and the scattered radiation from the various components of the collimation system. After approximate corrections were made for these effects, the agreement between the two dose distributions was within 2%. We also studied the impact of the ''tongue-and-groove'' effect on dynamic MLC treatments and showed that it is possible to render this effect inconsequential by appropriately synchronizing leaf motions. This study also demonstrated that accurate and rapid delivery of realistic intensity-modulated plans is feasible using a dynamic multi-leaf collimator. (C) 1996 American Association of Physicists in Medicine.
引用
收藏
页码:317 / 327
页数:11
相关论文
共 50 条
  • [21] Optimal field splitting for large intensity-modulated fields
    Kamath, S
    Sahni, S
    Ranka, S
    Li, J
    Palta, J
    MEDICAL PHYSICS, 2004, 31 (12) : 3314 - 3323
  • [22] Dosimetric comparison of helical tomotherapy and intensity-modulated radiotherapy in cervical cancer
    Liu, J.
    Zhu, L.
    Li, S.
    Gao, S.
    Yan, J.
    Xie, L.
    Hou, Z.
    Zhou, X.
    Liu, B.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S1005 - S1006
  • [23] Dosimetric Predictors of Dysphonia after Intensity-modulated Radiotherapy for Oropharyngeal Carcinoma
    Sanguineti, G.
    Ricchetti, F.
    McNutt, T.
    Wu, B.
    Fiorino, C.
    CLINICAL ONCOLOGY, 2014, 26 (01) : 32 - 38
  • [24] Quality assurance of intensity-modulated radiotherapy treatment planning: a dosimetric comparison
    Altaf, Saima
    Iqbal, Khalid
    Akram, Muhammad
    Buzdar, Saeed A.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2018, 17 (04) : 396 - 402
  • [25] Dosimetric Characterization of an Intensity-modulated X-Ray Brachytherapy System
    Lee, Sung-Woo
    Sozontov, Evgeny
    Strumban, Emil
    Yin, Fang-Fang
    JOURNAL OF MEDICAL PHYSICS, 2018, 43 (04) : 247 - 254
  • [26] Inverse radiotherapy planning for intensity-modulated photon fields
    K. Preiser
    Th. Bortfeld
    K. Hartwig
    W. Schlegel
    J. Stein
    Der Radiologe, 1998, 38 : 228 - 234
  • [27] Inverse radiotherapy planning for intensity-modulated photon fields
    Preiser, K
    Bortfeld, T
    Hartwig, K
    Schlegel, W
    Stein, J
    RADIOLOGE, 1998, 38 (03): : 228 - 234
  • [28] Comparison of gamma analysis with using different dosimetric systems for pre-treatment verification of intensity-modulated radiation therapy
    Inan, Gokcen
    Gul, Osman Vefa
    CANADIAN JOURNAL OF PHYSICS, 2021, 99 (05) : 390 - 396
  • [29] Dosimetric verification and quality assurance for intensity-modulated radiation therapy using Gafchromic (R) EBT3 film
    Iqbal, Khalid
    Iqbal, Muhammad Mazhar
    Akram, Muhammad
    Altaf, Saima
    Buzdar, Saeed Ahmad
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2018, 17 (01) : 85 - 95
  • [30] Verification of dynamic intensity-modulated beam deliveries in canine subjects
    Parsai, H
    Phillips, MH
    Cho, PS
    Kippenes, H
    Gavin, P
    Axen, D
    MEDICAL PHYSICS, 2001, 28 (11) : 2198 - 2208