摘要
The optimization of intensity distributions and the delivery of intensity-modulated treatments with dynamic multi-leaf collimators (MLC) offer important improvements to three-dimensional conformal radiotherapy. In this study, a nine-beam intensity-modulated prostate plan was generated using the inverse radiotherapy technique. The resulting fluence profiles were converted into dynamic MLC leaf motions as functions of monitor units. The leaf motion pattern data were then transferred to the MLC control computer and were used to guide the motions of the leaves during irradiation. To verify that the dose distribution predicted by the optimization and planning systems was actually delivered, a homogeneous polystyrene phantom was irradiated with each of the nine intensity-modulated beams incident normally on the phantom. For each exposure, a radiographic film was placed normal to the beam in the phantom to record the deposited dose. The films were calibrated and scanned to generate 2-D isodose distributions. The dose was also calculated by convolving the incident fluence pattern with pencil beams. The measured and calculated dose distributions were compared and found to have discrepancies in excess of 5% of the central axis dose. The source of discrepancies was suspected to be the rounded edges of the leaves and the scattered radiation from the various components of the collimation system. After approximate corrections were made for these effects, the agreement between the two dose distributions was within 2%. We also studied the impact of the ''tongue-and-groove'' effect on dynamic MLC treatments and showed that it is possible to render this effect inconsequential by appropriately synchronizing leaf motions. This study also demonstrated that accurate and rapid delivery of realistic intensity-modulated plans is feasible using a dynamic multi-leaf collimator. (C) 1996 American Association of Physicists in Medicine.
引用
下载
收藏
页码:317 / 327
页数:11
相关论文
共 50 条
  • [1] In vivo dosimetric verification of intensity-modulated radiation therapy
    Chytyk-Praznik, K.
    Van Uytven, E.
    Van Beek, T.
    McCurdy, B. M. C.
    MEDICAL PHYSICS, 2012, 39 (07) : 4629 - 4629
  • [2] Dosimetric verification of the dynamic intensity-modulated radiation therapy of 92 patients
    Tsai, Jen-San
    Wazer, David E.
    Ling, Marilyn N.
    Wu, Julian K.
    Fagundes, Marcio
    DiPetrillo, Thomas
    Kramer, Bradley
    Koistinen, Melita
    Engler, Mark J.
    International Journal of Radiation Oncology, Biology, Physics, 40 (05): : 1213 - 1230
  • [3] Dosimetric verification of the dynamic intensity-modulated radiation therapy of 92 patients
    Tsai, JS
    Wazer, DE
    Ling, MN
    Wu, JK
    Fagundes, M
    DiPetrillo, T
    Kramer, B
    Koistinen, M
    Engler, MJ
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 40 (05): : 1213 - 1230
  • [4] Dosimetric Comparison of Intensity-Modulated Arc Therapy and Intensity-Modulated Tadiotherapy of Cervical Carcinoma
    Liu, T.
    Zhang, G.
    Tao, C.
    Sun, T.
    Lin, X.
    MEDICAL PHYSICS, 2014, 41 (06) : 375 - 375
  • [5] Dosimetric verification for intensity-modulated radiotherapy of thoracic cancers using experimental and Monte Carlo approaches
    Jang, Si Young
    Liu, H. Helen
    Wang, Xiaochun
    Vassiliev, Oleg N.
    Siebers, Jeffrey V.
    Dong, Lei
    Mohan, Radhe
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : 939 - 948
  • [6] Attempted "seamless matchline" of intensity-modulated radiation therapy head & static neck fields for nasopharyngeal cancer: Treatment planning & dosimetric verification
    Huang, X
    Kuan, KM
    Xiao, GL
    Tsao, SY
    Qiu, XB
    Ng, K
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S639 - S639
  • [7] A system for three-dimensional dosimetric verification of treatment plans in intensity-modulated radiotherapy with heavy ions
    Karger, CP
    Jäkel, O
    Hartmann, GH
    Heeg, P
    MEDICAL PHYSICS, 1999, 26 (10) : 2125 - 2132
  • [8] Volumetric intensity-modulated arc therapy vs conventional intensity-modulated radiation therapy in nasopharyngeal carcinoma: a dosimetric study
    White, Peter
    Chan, Kit Chi
    Cheng, Ka Wai
    Chan, Ka Yiu
    Chau, Ming Chun
    JOURNAL OF RADIATION RESEARCH, 2013, 54 (03) : 532 - 545
  • [9] A Dosimetric Comparison of Inverse Intensity-modulated Radiotherapy and Forward Intensity-modulated Radiotherapy for Breast Cancer After Radical Mastectomy
    Zhang, G.
    Yin, Y.
    Lu, J.
    EUROPEAN JOURNAL OF CANCER, 2011, 47 : S341 - S342
  • [10] Dynamic splitting of large intensity-modulated fields
    Wu, QW
    Arnfield, M
    Tong, SD
    Wu, Y
    Mohan, R
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (07): : 1731 - 1740