Radiochemical ageing of highly filled EPDM seals as revealed by accelerated ageing and ageing in-service for 21 years

被引:15
|
作者
Pourmand, P. [1 ]
Hedenqvist, M. S. [1 ]
Furo, I. [2 ]
Gedde, U. W. [1 ]
机构
[1] KTH Royal Inst Technol, Sch Chem Sci & Engn, Fibre & Polymer Technol, SE-10044 Stockholm, Sweden
[2] KTH Royal Inst Technol, Sch Chem Sci & Engn, Dept Chem, SE-10044 Stockholm, Sweden
基金
瑞典研究理事会;
关键词
EthylEne propylene diene monomer rubber; Gamma radiation; Indenter modulus profiling; IR microscopy; Portable NMR spectroscopy; LONG-TERM PERFORMANCE; MECHANICAL-PROPERTIES; GAMMA-IRRADIATION; ACRYLATE) NANOCOMPOSITES; PHENOLIC ANTIOXIDANT; RUBBER; DEGRADATION; ELASTOMERS; NMR; POLYETHYLENE;
D O I
10.1016/j.polymdegradstab.2017.09.008
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Highly filled EPDM rubber used in cable transit seals in nuclear power plants were exposed to gamma radiation at a high dose rate at 23 degrees C in media with different oxygen partial pressures (1-21.2 kPa). The motivation of this study was threefold: highly filled polymers are replacing halogen-containing polymers and these materials have rendered less attention in the literature; there is a need to find efficient tools to make possible condition monitoring and extrapolation. Several profiling methods were used: IR microscopy, micro-indentation, micro-sample extraction/gravimetry and non-invasive NMR spectroscopy, and three different deterioration processes were identified: polymer oxidation, migration of low molar mass species, and anaerobic changes in the polymer network. IR microscopy, micro-indentation profiling and the portable NMR method confirmed diffusion-limited oxidation in samples irradiated in air. The inner non-oxidized part of the blocks showed a pronounced change in the indenter modulus by migration of primarily glyceryl tristearate migration was accelerated by the presence of oxygen in the surface layer and anaerobic changes in the polymer network. For extrapolation or for condition monitoring, it is best to use the data obtained by indenter modulus profiling and to use the correlation between indenter modulus and strain-at-break to quantify the sample status. Non-invasive NMR profiling provided useful data but was less precise than the indenter modulus data to predict the strain-at-break. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:473 / 484
页数:12
相关论文
共 37 条
  • [1] Near-infrared transmittance spectroscopy for radiochemical ageing of EPDM
    Lachenal, G
    Stevenson, I
    Celette, N
    [J]. ANALYST, 2001, 126 (12) : 2201 - 2206
  • [2] Radiochemical ageing of EPDM elastomers. 3. Mechanism of radiooxidation
    Rivaton, A
    Cambon, S
    Gardette, JL
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2005, 227 (03): : 357 - 368
  • [3] Radiochemical Ageing of ATH Filled Silane-Crosslinked Polyethylene
    Hettal, Sarah
    Roland, Sebastien
    Colin, Xavier
    [J]. MACROMOLECULAR SYMPOSIA, 2022, 405 (01)
  • [4] Factorial analysis for ageing assessment of in-service transformers
    Wang, Dongmiao
    Tee, Sheng Ji
    Liu, Qiang
    Wang, Zhongdong
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2018, 12 (13) : 3177 - 3185
  • [5] In-service ageing comparison study of natural ester and mineral oil filled distribution transformers
    Zhao, Yaohong
    Qian, Yihua
    Wei, Bin
    Wang, Ruifeng
    Rapp, Kevin James
    Xu, Yang
    [J]. 2019 IEEE 20TH INTERNATIONAL CONFERENCE ON DIELECTRIC LIQUIDS (ICDL), 2019,
  • [6] Deterioration of highly filled EPDM rubber by thermal ageing in air: Kinetics and non-destructive monitoring
    Pourmand, P.
    Hedenqvist, M. S.
    Furo, I.
    Gedde, U. W.
    [J]. POLYMER TESTING, 2017, 64 : 267 - 276
  • [7] Influence of the filler-matrix interface on ageing by γ-radiation of ATH filled EPDM
    De Almeida, A.
    Chazeau, L.
    Vigier, G.
    Marque, G.
    Monchy-Leroy, C.
    Goutille, Y.
    [J]. CONSTITUTIVE MODELS FOR RUBBER VIII, 2013, : 51 - 55
  • [8] Influence of fillers on mechanical properties of ATH filled EPDM during ageing by gamma irradiation
    Planes, Emilie
    Chazeau, Laurent
    Vigier, Gerard
    Fournier, Jerome
    Stevenson-Royaud, Isabelle
    [J]. POLYMER DEGRADATION AND STABILITY, 2010, 95 (06) : 1029 - 1038
  • [9] Understanding the Effects of In-Service Temperature and Functional Fluid on the Ageing of Silicone Rubber
    Kashi, Sima
    De Souza, Mandy
    Al-Assafi, Salwan
    Varley, Russell
    [J]. POLYMERS, 2019, 11 (03)
  • [10] Challenges in Oil Test Database Analysis for Ageing Assessment of In-Service Transformers
    Tee, S. J.
    Liu, Q.
    Wang, Z. D.
    Wilson, G.
    Jarman, P.
    Hooton, R.
    Walker, D.
    Dyer, P.
    [J]. 2015 50TH INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE (UPEC), 2015,