Hospital-based universal newborn hearing screening for early detection of permanent congenital hearing loss in Lagos, Nigeria

被引:36
|
作者
Olusanya, B. O. [1 ,2 ,3 ]
Wirz, S. L. [4 ]
Luxon, L. M. [1 ,2 ]
机构
[1] UCL, Inst Child Hlth, London WC1N 1EH, England
[2] UCL, Great Ormond St Hosp Children NHS Trust, London WC1N 1EH, England
[3] Univ Lagos, Coll Med, Inst Child Hlth & Primary Care, Surulere, Nigeria
[4] UCL, Inst Child Hlth, Ctr Int Hlth & Dev, London WC1N 1EH, England
关键词
congenital hearing loss; neonatal hearing screening; early detection; primary health workers; developing country;
D O I
10.1016/j.ijporl.2008.03.004
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objective: To determine the feasibility and effectiveness of hospital-based universal newborn hearing screening programme for the early detection of permanent congenital or early-onset hearing loss (PCEHL) in Lagos, Nigeria. Methods: A cross-sectional pilot study based on a two-stage universal newborn hearing screening by non-specialist health workers using transient evoked otoacoustic emissions (TEOAE) and automated auditory brainstem-response (AABR) in an inner-city maternity hospital over a consecutive period of 40 weeks. The main outcome measures were the practicality of screening by non-specialist staff with minimal training, functionality of screening instruments in an inner-city environment, screening coverage, referral rate, return rate for diagnosis, yield of PCEHL and average age of PCEHL confirmation. Results: Universal hearing screening of newborns by non-specialist staff without prior audiological. experience is feasible in an inner-city environment in Lagos after a training period of two-weeks. Notwithstanding excessive ambient noise within and outside the wards, it was possible to identify a test site for TEOAE screening within the hospital. The screening coverage was 98.7% (1330/1347) of all eligible newborns and the mean age of screening was 2.6 days. Forty-four babies out of the 1274 who completed the two-stage screening were referred yielding a referral rate of 3.5%. Only 16% (7/44) of babies scheduled for diagnostic evaluation returned and all were confirmed with hearing loss resulting in an incidence of 5.5 (7/1274) per 1000 live births or a programme yield of 5.3 (7/1330) per 1000. Six infants had bilateral hearing Loss and the degree was severe (>= 70 dB nHL) in three infants, moderate (40 dB nHL) in one infant and mild (<40 dB nHL) in two infants. The age at diagnosis ranged from 46 days to 360 days and only two infants were diagnosed within 90 days. Conclusions: Hospital-based universal hearing screening of newborns before discharge is feasible in Nigeria. Non-specialist staff are valuable in achieving a satisfactory referral rate with a two-stage screening protocol. However, a more efficient tracking and follow-up system is needed to improve the return rate for diagnosis and age of confirmation of hearing loss. (C) 2008 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:991 / 1001
页数:11
相关论文
共 50 条
  • [21] The Effect of Newborn Hearing Screening on the Development of Newborns with Congenital Hearing Loss
    Genc, Gulsum Aydan
    Barmak, Elife
    TURKIYE KLINIKLERI TIP BILIMLERI DERGISI, 2012, 32 (05): : 1284 - 1294
  • [23] Universal newborn hearing screening: Feasibility in a community hospital
    Huynh, MT
    Pollack, RA
    Cunningham, RAJ
    JOURNAL OF FAMILY PRACTICE, 1996, 42 (05): : 487 - 490
  • [24] Screening for early childhood hearing loss in Nigeria
    Olusanya, BO
    Luxon, LM
    Wirz, SL
    JOURNAL OF MEDICAL SCREENING, 2005, 12 (03) : 115 - 118
  • [25] Parental Refusal of Newborn Screening for Congenital Hearing Loss
    Char, Danton
    AMERICAN JOURNAL OF BIOETHICS, 2016, 16 (01): : 33 - 35
  • [26] Levels of evidence: universal newborn hearing screening (UNHS) and early hearing detection and intervention systems (EHDI)
    Yoshinaga-Itano, C
    JOURNAL OF COMMUNICATION DISORDERS, 2004, 37 (05) : 451 - 465
  • [27] Maternal and neonatal factors associated with mode of delivery under a universal newborn hearing screening programme in Lagos, Nigeria
    Olusanya, Bolajoko O.
    Solanke, Olumuyiwa A.
    BMC PREGNANCY AND CHILDBIRTH, 2009, 9 : 41
  • [28] Maternal and neonatal factors associated with mode of delivery under a universal newborn hearing screening programme in Lagos, Nigeria
    Bolajoko O Olusanya
    Olumuyiwa A Solanke
    BMC Pregnancy and Childbirth, 9
  • [29] Costs and performance of early hearing detection programmes in Lagos, Nigeria
    Olusanya, B. O.
    Emokpae, A.
    Renner, J. K.
    Wirz, S. L.
    TRANSACTIONS OF THE ROYAL SOCIETY OF TROPICAL MEDICINE AND HYGIENE, 2009, 103 (02) : 179 - 186
  • [30] Newborn hearing screening in the Campania region (Italy): early language and perceptual outcomes of infants with permanent hearing loss
    Marciano, E.
    Laria, C.
    Malesci, R.
    Iadicicco, P.
    Landolfi, E.
    Niri, C.
    Papa, C.
    Franze, A.
    Auletta, G.
    ACTA OTORHINOLARYNGOLOGICA ITALICA, 2013, 33 (06) : 414 - 417