Thermodynamic investigation of asynchronous inverse air cycle integrated with compressed-air energy storage

被引:7
|
作者
Giannetti, Niccolo [1 ]
Milazzo, Adriano [2 ]
Saito, Kiyoshi [3 ]
机构
[1] Waseda Univ, Waseda Inst Adv Study, Shinjuku Ku, 1-6-1 Nishiwaseda, Tokyo 1698050, Japan
[2] Univ Florence, Dept Ind Engn, Via Santa Marta 3, I-50139 Florence, Italy
[3] Waseda Univ, Dept Appl Mech & Aerosp Engn, Shinjuku Ku, 3-4-1 Okubo, Tokyo 1698555, Japan
关键词
Air-refrigerant; CAES; Thermodynamic investigation; Asynchronous cycle; REFRIGERATION; PERFORMANCE; EFFICIENCY;
D O I
10.1016/j.est.2021.103750
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A novel integrated system for heating, cooling, and compressed-air energy storage (CAES) is analysed from a thermodynamic perspective. The system is based on asynchronous air compression and expansion to take advantage of daily ambient temperature oscillations, electricity pricing variations, and the discontinuous availability of renewable sources. Furthermore, the integration of CAES with an open inverse air cycle eliminates grid and generator losses incurred in the supply of thermal energy for end-use heating and cooling applications. The novelty is represented by using the storage vessel as a heat exchanger interfaced with the external environment, which acts as a heat source or sink in relation to the ambient conditions and phase of operation. To ensure wide applicability, the analysis is kept on a fundamental level, without explicit reference to specific technical details of the components. The sole technical premise is represented by a commercially available vessel for air storage featuring a volume of 10 m(3) and a maximum operating pressure of 12 bar. This choice may be interpreted as a constituent unit for a modular system that can be easily scaled-up to the required capacity. Two configurations are proposed: one for air conditioning and sanitary water production, and the other for refrigeration. The first configuration yields a global COP of 1.49 and a second law efficiency of 0.149. The second one may produce heating at temperatures as high as 400 degrees C and refrigeration at -90 degrees C with a global COP of 1.30 and a second law efficiency of 0.192. The effects of losses in the compressor, expander, and heat exchangers, as well as heat transfer in storage vessel, are discussed, accounting also for condensation/evaporation due to the air humidity.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Comparative thermodynamic analysis of compressed air and liquid air energy storage systems
    Krawczyk, Piotr
    Szablowski, Lukasz
    Karellas, Sotirios
    Kakaras, Emmanuel
    Badyda, Krzysztof
    ENERGY, 2018, 142 : 46 - 54
  • [43] COMPRESSED-AIR SYSTEMS
    不详
    CHEMICAL ENGINEER-LONDON, 1991, (503): : 19 - 22
  • [44] PACKAGING COMPRESSED-AIR
    YEAPLE, F
    DESIGN ENGINEERING-LONDON, 1981, 52 (07): : 37 - 41
  • [45] Techno-Economic Analysis and Optimization of a Compressed-Air Energy Storage System Integrated with a Natural Gas Combined-Cycle Plant
    Sengalani, Pavitra Senthamilselvan
    Haque, Md Emdadul
    Zantye, Manali S.
    Gandhi, Akhilesh
    Li, Mengdi
    Hasan, M. M. Faruque
    Bhattacharyya, Debangsu
    ENERGIES, 2023, 16 (13)
  • [46] Application research of compressed-air energy storage under high proportion of renewable energy
    Feng, Bin
    Yu, Bo
    CLEAN ENERGY, 2022, 6 (02): : 1070 - 1077
  • [47] COMPRESSED-AIR FILTERS
    不详
    CONTROL AND INSTRUMENTATION, 1980, 12 (05): : 19 - 19
  • [48] BEWARE - COMPRESSED-AIR
    STEVENSON, S
    PULP & PAPER-CANADA, 1991, 92 (05) : 10 - 10
  • [49] The thermodynamic effect of thermal energy storage on compressed air energy storage system
    Zhang, Yuan
    Yang, Ke
    Li, Xuemei
    Xu, Jianzhong
    RENEWABLE ENERGY, 2013, 50 : 227 - 235
  • [50] A review on compressed-air energy use and energy savings
    Saidur, R.
    Rahim, N. A.
    Hasanuzzaman, M.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2010, 14 (04): : 1135 - 1153