Development and validation of a liquid chromatography-tandem mass spectrometry method for the determination of zofenopril and its active metabolite zofenoprilat in human plasma

被引:8
|
作者
Jiang, Yuan [1 ]
Yan, Fang [1 ]
Di, Bin [1 ,2 ]
Feng, Fang [1 ]
You, Linjun [1 ]
Huang, Lili [1 ]
Lu, Juan [1 ]
机构
[1] China Pharmaceut Univ, Dept Pharmaceut Anal, Nanjing 210009, Peoples R China
[2] Minist Educ, Key Lab Drug Qual Control & Pharmacovigilance, Nanjing 210009, Peoples R China
关键词
Zofenopril; Zofenoprilat; LC-MS/MS; Human plasma; Liquid-liquid extraction; CONVERTING-ENZYME-INHIBITOR; PHARMACOKINETICS;
D O I
10.1016/j.jpba.2011.02.010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel, sensitive and rapid liquid chromatographic-electrospray ionization mass spectrometric method was developed and validated for the determination of zofenopril and its active metabolite zofenoprilat in human plasma. The method was based on a single extraction step using methyl tert-butyl ether and did not require chemical derivatization. The chromatographic conditions were optimized; separation was performed on a phenyl-hexyl column (5 p,m, 250 mm x 4.6 mm id.) with a mobile phase consisting of a solution of methanol and water (95:5, v/v) that also contained 0.1% of formic acid. A flow rate of 1.0 mL/min was used. Zofenopril, zofenoprilat and the internal standard (IS) fosinopril sodium were measured using an electrospray ion source in a positive reaction monitoring mode. Linear calibration curves were generated for zofenopril concentrations between 0.1052 and 1052 ng/mL and for zofenoprilat concentrations between 0.2508 and 2508 ng/mL. In both cases, the coefficients of determination were greater than 0.995. The extraction recovery for zofenopril was 93.5% on average. It was 92.5% for zofenoprilat. The inter- and intra-batch precision and accuracy for both zofenopril and zofenoprilat were higher than 14%. The method was applied to measure the concentrations of zofenopril and zofenoprilat in plasma samples. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:527 / 532
页数:6
相关论文
共 50 条
  • [31] Determination of tandospirone in human plasma by a liquid chromatography-tandem mass spectrometry method
    Jin, Fengdan
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (09) : 2881 - 2887
  • [32] Development and validation of a liquid chromatography-tandem mass spectrometric method for the determination of α-methyltyrosine in human plasma
    Humphries, D
    Ruterbories, K
    Chan, C
    Narayanan, R
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 810 (02): : 229 - 234
  • [33] Development and validation of a liquid chromatography-tandem mass spectrometry method for the determination of ε-acetamidocaproic acid in rat plasma
    Kim T.H.
    Choi Y.S.
    Choi Y.H.
    Kim Y.G.
    [J]. Toxicological Research, 2013, 29 (3) : 203 - 209
  • [34] Development and Validation of a Liquid Chromatography-tandem Mass Spectrometry Method for the Simultaneous Determination of Acrivastine and Pseudoephedrine in Human Plasma and its Application in Pharmacokinetics
    He, J. -C.
    Feng, E. -F.
    Liu, M.
    Li, H. -L.
    Tian, M.
    Zhang, Q.
    Dong, L. -C.
    Xu, G. -L.
    [J]. ARZNEIMITTELFORSCHUNG-DRUG RESEARCH, 2012, 62 (10): : 449 - 456
  • [35] Development and validation of a high performance liquid chromatography-tandem mass spectrometry for the determination of etodolac in human plasma
    Lee, Hyun-Soo
    Kang, Il-Mo
    Lee, Heon-Woo
    Seo, Ji-Hyung
    Ryu, Ju-Hee
    Choi, Sang-Jun
    Lee, Myung-Jae
    Jeong, Seo-Young
    Cho, Young-Wuk
    Lee, Kyung-Tae
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 863 (01): : 158 - 162
  • [36] Bio-Analytical Method Development and Validation for Ramipril and Its Metabolite by Liquid Chromatography-Tandem Mass Spectrometry
    Gupta, C.
    Bhardwaj, N.
    Arora, S.
    [J]. INDIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2023, 85 (04) : 1126 - 1136
  • [37] Quantitative Determination of Amitriptyline and Its Metabolite in Rat Plasma by Liquid Chromatography-tandem Mass Spectrometry
    Chae, Jung-woo
    Baek, In-hwan
    An, Jung-hwa
    Kim, Eun Jung
    Kwon, Kwang-il
    [J]. BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2012, 33 (07) : 2163 - 2167
  • [38] Quantitative determination of nitrendipine and its metabolite dehydronitrendipine in human plasma using liquid chromatography-tandem mass spectrometry
    Chen, XY
    Zhong, DF
    Yang, HY
    Luan, Y
    Xu, HY
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2001, 15 (08) : 518 - 524
  • [39] A liquid chromatography-tandem mass spectrometry method for the simultaneous determination of exemestane and its metabolite 17-dihydroexemestane in human plasma
    Corona, Giuseppe
    Elia, Caterina
    Casetta, Bruno
    Diana, Crivellari
    Rosalen, Sara
    Bari, Mario
    Toffoli, Giuseppe
    [J]. JOURNAL OF MASS SPECTROMETRY, 2009, 44 (06): : 920 - 928
  • [40] Validation of a method for quantification of ketobemidone in human plasma with liquid chromatography-tandem mass spectrometry
    Lampinen, M
    Bondesson, U
    Fredriksson, E
    Hedeland, M
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 789 (02): : 347 - 354