Determination of residual levels of metrafenone in lettuce grown under greenhouse conditions using gas chromatography with a micro-electron capture detector

被引:11
|
作者
Kabir, Md. Humayun [1 ]
Abd El-Aty, A. M. [2 ,3 ]
Im, So Jeong [1 ]
Rahman, Md. Musfiqur [1 ]
Kim, Sung-Woo [1 ]
Farha, Waziha [1 ]
Choi, Jeong-Heui [1 ]
Jung, Da-I [1 ]
Lee, Young-Jun [1 ]
Lieu, Troung [1 ]
Shin, Ho-Chul [2 ]
Im, Geon-Jae [4 ]
Hong, Su-Myeong [4 ]
Shim, Jae-Han [1 ]
机构
[1] Chonnam Natl Univ, Biotechnol Res Inst, 77 Yongbong Ro, Gwangju 500757, South Korea
[2] Konkuk Univ, Coll Vet Med, Dept Vet Pharmacol & Toxicol, 1 Hwayang Dong, Seoul 143701, South Korea
[3] Cairo Univ, Fac Vet Med, Dept Pharmacol, Giza 12211, Egypt
[4] Rural Dev Adm, Natl Acad Agr Sci, Dept Agrofood Safety, Wonju 560500, South Korea
关键词
Metrafenone; Lettuce; Gas chromatography-micro electron capture detector; Decline; Half-life; PESTICIDES; DEGRADATION; FIBER;
D O I
10.1007/s13765-015-0126-7
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
The current study was carried out to detect metrafenone residues and estimate the half-lives in lettuce grown under greenhouse conditions using gas chromatography with a micro-electron capture detector. Metrafenone was applied in two and three doses (with a 7-day interval) to two different sites in Naju (distance between sites 1 and 2 = 6.5 km) in different seasons (spring and autumn). Samples were extracted with acetone and matrix components were purified using a silica solid-phase extraction (SPE) cartridge. The calibration curve over the concentration range of 0.02-5.0 mg/L was linear with a determination coefficient (R-2) = 0.9993. The limits of detection and quantification were 0.003 and 0.01 mg/L, respectively. Recoveries at two fortification levels (0.1 and 0.5 mg/kg) ranged from 78.5 to 113.3 % with a relative standard deviation <8 %. The calculated half-lives were 2.3 and 2.2 days and 4.9 and 5.0 days for the double and triple doses at sites 1 and 2, respectively. These results suggest that the method is effective and sensitive for the determination of metrafenone residues in field-incurred lettuce samples, and the difference in the reported half-lives is due to seasonal variation.
引用
收藏
页码:43 / 49
页数:7
相关论文
共 50 条
  • [41] Determination of Twelve Kinds of Volatile Disinfection Byproducts in Drinking Water by Gas Chromatography with Electron Capture Detector
    Zhang Zhong-Xiang
    Zhao Qi
    Liu Yu-Lei
    Ma Jun
    Qi Jing-Yao
    Ren Zhi-Jun
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 45 (08) : 1203 - 1208
  • [42] Solid-phase nanoextraction of polychlorinated biphenyls in water and their determination by gas chromatography with electron capture detector
    Piramoon, Shadi
    Azar, Parviz Aberoomand
    Tehrani, Mohammad Saber
    Mohammadiazar, Sirwan
    Tavassoli, Abdollah
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (02) : 449 - 457
  • [43] Direct Acetylation and Determination of Chlorophenols in Aqueous Samples by Gas Chromatography Coupled with an Electron-Capture Detector
    Al-Janabi, Khalid Waleed S.
    Alazawi, Fatin Nafea
    Mohammed, M. Ibrahim
    Kadhum, Abdul Amir H.
    Mohamad, Abu Bakar
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2012, 50 (07) : 564 - 568
  • [45] DETERMINATION OF DEPHOSPHATE-BROMOPHENOPHOS EXCRETED IN COWS MILK BY GAS-LIQUID-CHROMATOGRAPHY USING AN ELECTRON-CAPTURE DETECTOR
    FUKUHARA, K
    MATSUKI, Y
    NAMBARA, T
    JOURNAL OF THE FOOD HYGIENIC SOCIETY OF JAPAN, 1985, 26 (06): : 658 - 661
  • [46] Residual pattern of acequinocyl and hydroxyacequinocyl in perilla leaf grown under greenhouse conditions using ultra performance liquid chromatography-photo diode array detector with tandem mass confirmation
    Tae Woong Na
    Md. Musfiqur Rahman
    Jong-Hyouk Park
    Angel Yang
    Ki Hun Park
    A. M. Abd El-Aty
    Jae-Han Shim
    Journal of the Korean Society for Applied Biological Chemistry, 2012, 55 : 657 - 662
  • [47] Residual Pattern of Acequinocyl and Hydroxyacequinocyl in Perilla Leaf Grown under Greenhouse Conditions using Ultra Performance Liquid Chromatography-Photo Diode Array Detector with Tandem Mass Confirmation
    Na, Tae Woong
    Rahman, Md. Musfiqur
    Park, Jong-Hyouk
    Yang, Angel
    Park, Ki Hun
    Abd El-Aty, A. M.
    Shim, Jae-Han
    JOURNAL OF THE KOREAN SOCIETY FOR APPLIED BIOLOGICAL CHEMISTRY, 2012, 55 (05): : 657 - 662
  • [48] Fast gas chromatography of explosive compounds using a pulsed-discharge electron capture detector
    Collin, Olivier L.
    Niegel, Claudia
    DeRhodes, Kate E.
    McCord, Bruce R.
    Jackson, Glen P.
    JOURNAL OF FORENSIC SCIENCES, 2006, 51 (04) : 815 - 818
  • [49] DETERMINATION OF TRACE LEVELS OF TOLUENE-2,4-DIISOCYANATE BY ELECTRON CAPTURE GAS CHROMATOGRAPHY
    WHEALS, BB
    THOMSON, J
    CHEMISTRY & INDUSTRY, 1967, (18) : 753 - &
  • [50] DETERMINATION OF AMITRIPTYLINE AT NANOGRAM LEVELS IN SERUM BY ELECTRON-CAPTURE GAS-LIQUID-CHROMATOGRAPHY
    WALLACE, JE
    HAMILTON, HE
    GOGGIN, LK
    BLUM, K
    ANALYTICAL CHEMISTRY, 1975, 47 (09) : 1516 - 1519