Dynamic assessment of paranasal sinus ventilation using xenon-enhanced computed tomography

被引:10
|
作者
Marcucci, C
Leopold, DA
Cullen, M
Zinreich, SJ
Simon, BA
机构
[1] Johns Hopkins Med Inst, Dept Anesthesiol & Crit Care Med, Baltimore, MD 21205 USA
[2] Johns Hopkins Med Inst, Dept Otolaryngol Head & Neck Surg, Baltimore, MD 21205 USA
[3] Johns Hopkins Med Inst, Dept Radiol, Baltimore, MD 21205 USA
来源
关键词
airflow; diagnostics; imaging; sinus; xenon ventilation;
D O I
10.1177/000348940111001014
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Disease of the paranasal sinuses is a common and costly condition. Evaluation of the efficacy of either medical or surgical methods of treatment is limited by the lack of quantitative methods to characterize sinus ventilation. which may be an important determinant of the baseline physiological state of the sinuses. Xenon-enhanced computed tomography (Xe-CT) measurement of sinus ventilation provides a noninvasive method of quantifying maxillary sinus ventilation using the nonradioactive. radiodense gas Xe as a tracer. Study subjects breathed a mixture of Xe gas and oxygen through a close-fitting nasal mask during serial CT imaging of a single radiographic plane through the maxillary sinuses - a generally well-tolerated protocol. Analysis of the sinus density-time curves allowed calculation of first-order exponential time constants from which specific ventilation rates could be determined for individual sinuses. Previously developed data analysis techniques were used to assess the statistical significance of the data and determine confidence intervals, allowing examination of the effects of noise in the data, and to demonstrate areas for further study protocol refinement. We conclude that Xe-CT measurement of sinus ventilation is a potentially valuable noninvasive technique for the diagnostic imaging of the human maxillary sinus.
引用
收藏
页码:968 / 975
页数:8
相关论文
共 50 条
  • [21] Washout of 133-xenon as an objective assessment of paranasal sinus ventilation in endoscopic sinus surgery
    Paulsson, B
    Lindberg, S
    Ohlin, P
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2002, 111 (08): : 710 - 717
  • [22] REGIONAL PULMONARY VENTILATION MEASUREMENTS BY XENON ENHANCED DYNAMIC COMPUTED-TOMOGRAPHY - AN UPDATE
    GUR, D
    SHABASON, L
    BOROVETZ, HS
    HERBERT, DL
    REECE, GJ
    KENNEDY, WH
    SERAGO, C
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1981, 5 (05) : 678 - 683
  • [23] Predicting stroke risk in pediatric moyamoya disease with xenon-enhanced computed tomography
    McAuley, DJ
    Poskitt, K
    Steinbok, P
    NEUROSURGERY, 2004, 55 (02) : 327 - 332
  • [24] Xenon-enhanced computed tomography assessment of brown adipose tissue distribution and perfusion in lean, obese, and diabetic primates
    Garside, John C.
    Kavanagh, Kylie
    Block, Masha R.
    Williams, Abigail G.
    Branca, Rosa T.
    OBESITY, 2022, 30 (09) : 1831 - 1841
  • [25] Noninvasive Quantitative Measurement of Tissue Blood Flow in Hepatocellular Carcinoma Using Xenon-Enhanced Computed Tomography
    Junzo Shimizu
    Hiroshi Oka
    Keizo Dono
    Masato Sakon
    Manabu Takamura
    Takamichi Murakami
    Shouho Hayashi
    Hiroaki Nagano
    Shoji Nakamori
    Koji Umeshita
    Shigeru Sase
    Mitsukazu Gotoh
    Kenichi Wakasa
    Hironobu Nakamura
    Morito Monden
    Digestive Diseases and Sciences, 2003, 48 : 1510 - 1516
  • [26] Noninvasive quantitative measurement of tissue blood flow in hepatocellular carcinoma using xenon-enhanced computed tomography
    Shimizu, J
    Oka, H
    Dono, K
    Sakon, M
    Takamura, M
    Murakami, T
    Hayashi, S
    Nagano, H
    Nakamori, S
    Umeshita, K
    Sase, S
    Gotoh, M
    Wakasa, K
    Nakamura, H
    Monden, M
    DIGESTIVE DISEASES AND SCIENCES, 2003, 48 (08) : 1510 - 1516
  • [27] Predicting stroke risk in pediatric moyamoya disease with xenon-enhanced computed tomography - Comments
    Levy, ML
    Scott, RM
    Sutton, LN
    Nelson, MD
    NEUROSURGERY, 2004, 55 (02) : 332 - 333
  • [28] Ventilation imaging of the paranasal sinuses using xenon-enhanced dynamic single-energy CT and dual-energy CT: a feasibility study in a nasal cast
    Thieme, Sven F.
    Moeller, Winfried
    Becker, Sven
    Schuschnig, Uwe
    Eickelberg, Oliver
    Helck, Andreas D.
    Reiser, Maximilian F.
    Johnson, Thorsten R. C.
    EUROPEAN RADIOLOGY, 2012, 22 (10) : 2110 - 2116
  • [29] Ventilation imaging of the paranasal sinuses using xenon-enhanced dynamic single-energy CT and dual-energy CT: a feasibility study in a nasal cast
    Sven F. Thieme
    Winfried Möller
    Sven Becker
    Uwe Schuschnig
    Oliver Eickelberg
    Andreas D. Helck
    Maximilian F. Reiser
    Thorsten R. C. Johnson
    European Radiology, 2012, 22 : 2110 - 2116
  • [30] Determination of time-course change rate for arterial xenon using the time course of tissue xenon concentration in xenon-enhanced computed tomography
    Sase, Shigeru
    Takahashi, Hideaki
    Ikeda, Hiroki
    Kobayashi, Minoru
    Matsumoto, Nobuyuki
    Suzuki, Michihiro
    MEDICAL PHYSICS, 2008, 35 (06) : 2331 - 2338