Use of multi-angle laser light scattering and size-exclusion chromatography to characterize the molecular weight and types of aggregates present in commercial whey protein products

被引:72
|
作者
Wang, T [1 ]
Lucey, JA [1 ]
机构
[1] Univ Wisconsin, Dept Food Sci, Madison, WI 53706 USA
关键词
whey protein; size-exclusion chromatography; multi-angle laser light scattering; molar mass;
D O I
10.3168/jds.S0022-0302(03)73909-5
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
In this study, a range of commercial whey protein products were characterized by the use of size-exclusion chromatography coupled with a multi-angle laser light scattering (MALLS) detector. The MALLS system detected some very large-sized material that eluted close to void volume in all samples; this material was hardly detected by concentration detector. It was demonstrated by chitosan treatment that this peak was very small lipid globules or phospholipids, which gave the residual "cloudy" appearance in upper layers after ultracentrifugation of whey products. Composition, molecular weight, and the photo diode array (PDA) spectrum (200 to 400 nm) of the major protein peaks, including: beta-lactoglobulin (BLG), alpha-lactalbumin (ALA), bovine serum albumin (BSA), immunoglobulin G (IgG) and some minor components were analyzed. The molecular weight of BLG, ALA, BSA, and IgG peaks in whey protein isolates (WPI) were 2.3 to 3.7 x 10(4), 1.4 to 1.6 x 10(4), 4.8 to 6.7 x 10(4), and 1.2 to 2.5 x 10(5) Da, respectively. Compared with WPI, WPC has similar major proteins, but more large-sized residual lipid material and different minor constituents such as lactose and nonprotein nitrogen, depending on various commercial samples and protein content. An improved TCA-precipitation method was applied to quantify glycomacropeptide (GMP) in whey proteins, which demonstrated that there was a very low concentration of GMP in WPI manufactured using an ion-exchange process. The molecular weight of GMP was found to be similar to8600 Da. Size-exclusion chromatography MALLS was demonstrated to be a powerful technique for detailed analysis of the molecular weight of various proteins, aggregates and minor components, such as GMP, in whey protein products.
引用
收藏
页码:3090 / 3101
页数:12
相关论文
共 50 条
  • [21] Comparative study of protein molecular weights by size-exclusion chromatography and laser-light scattering
    Oliva, A
    Llabrés, M
    Fariña, JB
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 25 (5-6) : 833 - 841
  • [22] Characterization of complexes of PF4 and heparins by size-exclusion chromatography coupled with multi-angle light scattering detector
    Zhao, Jingwen
    Xue, Yiting
    Tian, He
    Qiu, Piaopiao
    Ouyang, Yilan
    Liu, Haiying
    Yi, Lin
    Zhang, Zhenqing
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2024, 1233
  • [23] Determination of the absolute molar mass of acetylated eucalyptus kraft lignin by two types of size-exclusion chromatography combined with multi-angle laser light-scattering detectors
    Wang, Linping
    Uraki, Yasumitsu
    Koda, Keiichi
    Gele, Aori
    Zhou, Xuesong
    Chen, Fangeng
    HOLZFORSCHUNG, 2019, 73 (04) : 363 - 369
  • [24] Quality Control of Polysaccharide Molecular-Weight Distributions Using Exclusion Chromatography with a Multi-Angle Laser Light Scattering Detector
    Karyakin, A. V.
    Beksaev, S. G.
    Flegontov, P. A.
    PHARMACEUTICAL CHEMISTRY JOURNAL, 2014, 48 (07) : 470 - 477
  • [25] Quality Control of Polysaccharide Molecular-Weight Distributions Using Exclusion Chromatography with a Multi-Angle Laser Light Scattering Detector
    A. V. Karyakin
    S. G. Beksaev
    P. A. Flegontov
    Pharmaceutical Chemistry Journal, 2014, 48 : 470 - 477
  • [26] On-line direct determination of the second virial coefficient of a natural polysaccharide using size-exclusion chromatography and multi-angle laser light scattering
    Girod, S
    Baldet-Dupy, P
    Maillols, H
    Devoisselle, JM
    JOURNAL OF CHROMATOGRAPHY A, 2002, 943 (01) : 147 - 152
  • [27] Molar masses and sizes of starches by high-performance size-exclusion chromatography with on-line multi-angle laser light scattering detection
    Fishman, ML
    Rodriguez, L
    Chau, HK
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1996, 44 (10) : 3182 - 3188
  • [28] Branched Structures of Softwood Celluloses: Proof Based on Size-Exclusion Chromotography and Multi-Angle Laser-Light Scattering
    Ono, Yuko
    Saito, Tsuguyuki
    Isogai, Akira
    NANOCELLULOSES: THEIR PREPARATION, PROPERTIES, AND APPLICATIONS, 2017, 1251 : 151 - 169
  • [29] Rapid size distribution and purity analysis of gastric mucus glycoproteins by size exclusion chromatography multi-angle laser light scattering
    Jumel, K
    Fiebrig, I
    Harding, SE
    INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 1996, 18 (1-2) : 133 - 139
  • [30] Molecular weights and gyration radii of amylopectins determined by high-performance size-exclusion chromatography equipped with multi-angle laser-light scattering and refractive index detectors
    Yoo, SH
    Jane, JL
    CARBOHYDRATE POLYMERS, 2002, 49 (03) : 307 - 314