Amniotic fluid lamellar body counts for the determination of fetal lung maturity: an update

被引:16
|
作者
Piazze, JJ [1 ]
Maranghi, L [1 ]
Cerekja, A [1 ]
Meloni, P [1 ]
Gioia, S [1 ]
Fumian, L [1 ]
Cosmi, EV [1 ]
Anceschi, MM [1 ]
机构
[1] Univ Roma La Sapienza, Inst Gynecol Perinatol & Child Hlth, Rome, Italy
关键词
fetal lung maturity; lamellar body counts;
D O I
10.1515/JPM.2005.029
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Aim: To reassess the cut-off value for lamellar body counts (LBs) for fetal lung maturity (FLM) over a 10-year study period. Patients and methods: 178 pregnancies were selected under strict inclusion criteria and delivered within 48 h from amniocentesis. FLM was determined by amniotic fluid LBs in centrifuged samples (300 x g for 10 min) in a commercially available Coulter Counter. Cases beyond 37 weeks were excluded. Results: Mean gestational age was 33.5 +/- 3.0 weeks at amniocentesis and 33.7 +/- 3.0 weeks at birth. After reassessing the best compromise between sensitivity and specificity for all cases using the receiver operating characteristic (ROC) procedure, an FLM cut-off value of <= 22,000/mu L was obtained. Diagnostic accuracy (and confidence interval, Cl) was: sensitivity, 73% (60.0-83.6%); specificity, 81.7% (CI 73.6-88.1%); positive predictive value, 66.2%; and negative predictive value, 86.0%. Conclusion: No significant change in FLM cut-off for LBs was found when comparing the value from this study and the results of our earlier report presented in 1996 (<= 22,000 vs. <= 20,000/mu L), although the new value may be more accurate, since it is based on neonatal outcome with the exclusion of cases in which the diagnosis of FLM is seldom warranted, i.e., > 37 weeks' gestational age.
引用
收藏
页码:156 / 160
页数:5
相关论文
共 50 条
  • [21] Amniotic fluid lamellar body count: Cost-effective screening for fetal lung maturity - In reply
    Lewis, PS
    OBSTETRICS AND GYNECOLOGY, 1999, 94 (03): : 482 - 482
  • [22] AMNIOTIC-FLUID LAMELLAR BODY PHOSPHOLIPID CONTENT AND FETAL PULMONARY MATURITY
    IVIE, WM
    SWANSON, JR
    NOVY, MJ
    CLINICAL CHEMISTRY, 1982, 28 (07) : 1661 - 1661
  • [23] Evaluation of lamellar body counts in testing strategies for fetal lung maturity.
    Baptist, SJ
    DelaflorWeiss, E
    CLINICAL CHEMISTRY, 1997, 43 : 417 - 417
  • [24] DETERMINATION OF AMNIOTIC-FLUID MICROVISCOSITY AT BODY-TEMPERATURE - A PREDICTOR OF FETAL LUNG MATURITY
    BARKAI, G
    MODAN, M
    GOLDMAN, B
    LUSKY, A
    BRISH, M
    MASHIACH, S
    OBSTETRICS AND GYNECOLOGY, 1985, 65 (04): : 573 - 579
  • [25] Lamellar body counts - A rapid, reliable and cost-effective primary assay for fetal lung maturity determination
    Viljoen, A
    Vermaak, WJH
    SAMJ SOUTH AFRICAN MEDICAL JOURNAL, 2002, 92 (04): : 287 - 288
  • [26] ASSESSMENT OF FETAL LUNG MATURITY BY AMNIOTIC-FLUID LECITHIN DETERMINATION
    POLJAKOVIC, L
    LAZAREVIC, B
    JUZNIC, N
    ACTA PHARMACEUTICA JUGOSLAVICA, 1990, 40 (04): : 561 - 567
  • [27] DETERMINATION OF FETAL LUNG MATURITY BY FLUORESCENCE POLARIZATION OF AMNIOTIC-FLUID
    BLUMENFELD, TA
    STARK, RI
    JAMES, LS
    GEORGE, JD
    DYRENFURTH, I
    FREDA, VJ
    SHINITZKY, M
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1978, 130 (07) : 782 - 787
  • [28] The use of lamellar body counts as a predictor of fetal lung maturity in pregnancies complicated by diabetes
    Deroche, M
    Ingardia, C
    Guerette, P
    Wu, A
    Lasala, C
    Mandavilla, S
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2001, 185 (06) : S238 - S238
  • [29] Lamellar body counts performed on automated hematology analyzers to assess fetal lung maturity
    Lu, Ji
    Gronowski, Ann M.
    Eby, Charles
    LABMEDICINE, 2008, 39 (07): : 419 - 423
  • [30] The use of lamellar body counts to predict fetal lung maturity in pregnancies complicated by diabetes mellitus
    DeRoche, ME
    Ingardia, CJ
    Guerette, PJ
    Wu, AH
    LaSala, CA
    Mandavilli, SR
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2002, 187 (04) : 908 - 912