Atrial fibrillation detection in primary care during blood pressure measurements and using a smartphone cardiac monitor

被引:3
|
作者
Sluyter, John D. [1 ]
Scragg, Robert [1 ]
Ofanoa, Malakai [1 ]
Stewart, Ralph A. H. [2 ]
机构
[1] Univ Auckland, Sch Populat Hlth, Private Bag 92019, Auckland, New Zealand
[2] Auckland City Hosp, Green Lane Cardiovasc Serv, Auckland, New Zealand
关键词
DIAGNOSTIC-ACCURACY;
D O I
10.1038/s41598-021-97475-1
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Improved atrial fibrillation (AF) screening methods are required. We detected AF with pulse rate variability (PRV) parameters using a blood pressure device (BP+; Uscom, Sydney, Australia) and with a Kardia Mobile Cardiac Monitor (KMCM; AliveCor, Mountain View, CA). In 421 primary care patients (mean (range) age: 72 (31-99) years), we diagnosed AF (n = 133) from 12-lead electrocardiogram recordings, and performed PRV and KMCM measurements. PRV parameters detected AF with area under curve (AUC) values of up to 0.92. Using the mean of two sequential readings increased AUC to up to 0.94 and improved positive predictive value at a given sensitivity (by up to 18%). The KMCM detected AF with 83% sensitivity and 68% specificity. 89 KMCM recordings were "unclassified" or blank, and PRV detected AF in these with AUC values of up to 0.88. When non-AF arrhythmias (n = 56) were excluded, the KMCM device had increased specificity (73%) and PRV had higher discrimination performance (maximum AUC = 0.96). In decision curve analysis, all PRV parameters consistently achieved a positive net benefit across the range of clinical thresholds. In primary care, AF can be detected by PRV accurately and by KMCM, especially in the absence of non-AF arrhythmias or when combinations of measurements are used.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Diagnostic accuracy of a home blood pressure monitor to detect atrial fibrillation
    G S Stergiou
    N Karpettas
    A Protogerou
    E G Nasothimiou
    M Kyriakidis
    Journal of Human Hypertension, 2009, 23 : 654 - 658
  • [22] Atrial fibrillation detection with a portable device during cardiovascular screening in primary care
    Diamantino, Adriana C.
    Nascimento, Bruno R.
    Beaton, Andrea Z.
    Nunes, Maria Carmo P.
    Oliveira, Kaciane K. B.
    Rabelo, Lara C.
    Barbosa, Marcia M.
    Tompsett, Alison R.
    Olivieri, Laura
    Mata, Mariana D.
    Costa, Waydder Antonio A.
    Pereira, Augusto F.
    Diamantino, Luciana C.
    Ribeiro, Antonio Luiz P.
    Sable, Craig
    Brant, Luisa C. C.
    HEART, 2020, 106 (16) : 1261 - 1266
  • [23] Reliable detection and quantification of atrial fibrillation using an insertable cardiac monitor: results of the XPECT trial
    Puererfellner, H.
    Kuck, K. -H.
    Pokushalov, E.
    Hatala, R.
    Taborsky, M.
    Lebedev, D.
    Rieger, G.
    Beckers, F.
    Rogers, T.
    Hindricks, G.
    EUROPEAN HEART JOURNAL, 2009, 30 : 825 - 826
  • [24] Prediction of atrial fibrillation using a home blood pressure monitor with a high-resolution system
    Hiyoshi, Yasunaga
    Hashimoto, Hidenobu
    Kabuki, Takayuki
    Toda, Mikihito
    Sakurada, Harumizu
    OPEN HEART, 2022, 9 (02):
  • [25] Will Smartphone Applications Replace the Insertable Cardiac Monitor in the Detection of Atrial Fibrillation? The First Comparison in a Case Report of a Cryptogenic Stroke Patient
    Wouters, Femke
    Gruwez, Henri
    Vranken, Julie
    Ernon, Ludovic
    Mesotten, Dieter
    Vandervoort, Pieter
    Verhaert, David
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [26] Opportunistic detection of atrial fibrillation using blood pressure monitors: a systematic review
    Kane, Sarah A.
    Blake, James R.
    McArdle, Frank J.
    Langley, Philip
    Sims, Andrew J.
    OPEN HEART, 2016, 3 (01):
  • [27] Comparison of Noninvasive Blood Pressure Measurements in Patients With Atrial Fibrillation
    Anastas, Zoe M.
    Jimerson, Elnora
    Garolis, Salomeja
    JOURNAL OF CARDIOVASCULAR NURSING, 2008, 23 (06) : 519 - 524
  • [28] Does controlled atrial fibrillation affect blood pressure measurements?
    Jani, B
    Bulpitt, C
    Rajkumar, C
    JOURNAL OF HYPERTENSION, 2004, 22 : S281 - S281
  • [29] Is an Implantable Cardiac Monitor the Standard of Care for Determining the Success of Atrial Fibrillation Ablation?
    Andrade, Jason G.
    Krahn, Andrew D.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2013, 24 (10) : 1083 - 1085
  • [30] New concept of pulse irregularity for the detection of atrial fibrillation during blood pressure measurement
    Watanabe, Tomonori
    Hoshide, Satoshi
    Kario, Kazuomi
    HYPERTENSION RESEARCH, 2022, 45 (09) : 1520 - 1522