Metal displacement and stoichiometry of protein-metal complexes under native conditions using capillary electrophoresis/mass spectrometry

被引:34
|
作者
Moini, Mehdi [1 ]
机构
[1] Smithsonian Inst, Museum Conservat Inst, Suitland, MD 20746 USA
关键词
ELECTROSPRAY MASS-SPECTROMETRY; ZONE-ELECTROPHORESIS; BACILLUS-THURINGIENSIS; CIRCULAR-DICHROISM; ION INTERACTIONS; BINDING; METALLOTHIONEIN; MS; IDENTIFICATION; CADMIUM(II);
D O I
10.1002/rcm.4702
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Increases in the study of protein-metal complexes, as well as in metal displacement in protein-metal complexes under native conditions for optimum catalytic properties in drug research and catalyst design, demands a separation/detection technology that can accurately measure metal displacement and stoichiometry in protein-metal complexes. Both nuclear magnetic resonance (NMR) and X-ray diffraction techniques have been used for this purpose; however, these techniques lack sensitivity. Electrospray ionization mass spectrometry (ESI-MS) using direct infusion offers higher sensitivity than the former techniques and provides molecular distribution of various protein-metal complexes. However, since protein-metal complexes under native conditions usually are dissolved in salt solutions, their direct ESI-MS analysis requires off-line sample clean-up prior to MS analysis to avoid sample suppression during ESI. Moreover, direct infusion of the salty solution promotes nonspecific salt adduct formation by the protein-metal complexes under ESI-MS, which complicates the identification and stoichiometry measurements of the protein-metal complexes. Because of the high mass of protein-metal complexes and lack of sufficient resolution by most mass spectrometers to separate non-specific from specific metal-protein complexes, accurate protein-metal stoichiometry measurements require some form of sample clean up prior to ESI-MS analysis. In this study, we demonstrate that capillary electrophoresis/electrospray ionization in conjunction with a medium-resolution (similar to 10 000) mass spectrometer is an efficient and fast method for the measurement of the stoichiometry of the protein-metal complexes under physiological conditions (pH similar to 7). The metal displacement of Co2+ to Cd2+, two metal ions necessary for activation in the monomeric AHL lactonase produced by B. thuringiensis, has been used as a proof of concept. Copyright (c) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:2730 / 2734
页数:5
相关论文
共 50 条
  • [21] Ultraviolet native fluorescence detection in capillary electrophoresis using a metal vapor NeCu laser
    Zhang, X
    Sweedler, JV
    ANALYTICAL CHEMISTRY, 2001, 73 (22) : 5620 - 5624
  • [22] Simultaneous detection of 5 heavy metal complexes using capillary zone electrophoresis
    Department of Chemical Engineering, Tsinghua University, Beijing 100084, China
    不详
    Qinghua Daxue Xuebao, 2006, 3 (384-388):
  • [23] Characterization of Native Protein Complexes Using Ultraviolet Photodissociation Mass Spectrometry
    O'Brien, John P.
    Li, Wenzong
    Zhang, Yan
    Brodbelt, Jennifer S.
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2014, 136 (37) : 12920 - 12928
  • [24] Characterization of monoclonal antibody charge variants under near-native separation conditions using nanoflow sheath liquid capillary electrophoresis-mass spectrometry
    Zon, Annika A. M. van der
    Hoechsmann, Alisa
    Bos, Tijmen S.
    Neusuess, Christian
    Somsen, Govert W.
    Jooss, Kevin
    Haselberg, Rob
    Gargano, Andrea F. G.
    ANALYTICA CHIMICA ACTA, 2024, 1331
  • [25] Charge-dependent modulation of specific and nonspecific protein-metal ion interactions in nanoelectrospray ionization mass spectrometry
    Zheng, Shihui
    Yuan, Siming
    Hou, Zhuanghao
    Li, Gongyu
    Chen, Yuting
    Pan, Yang
    Liu, Yangzhong
    Huang, Guangming
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2019, 33 (19) : 1502 - 1511
  • [26] Mobility capillary electrophoresis-native mass spectrometry reveals the dynamic conformational equilibrium of calmodulin and its complexes
    Zhao, Yi
    Zhang, Wenjing
    Hong, Jie
    Yang, Lei
    Wang, Yuanyuan
    Qu, Feng
    Xu, Wei
    ANALYST, 2024, 149 (14) : 3793 - 3802
  • [27] Accurate quantification of metal-glycinates-sulphate complexes and free metals in feed by capillary electrophoresis inductively coupled plasma mass spectrometry
    Ionescu, Catherine
    Grill, Peter
    Witte, Heidi
    Boigues, Christian
    Blanchard, Alexandra
    Loeffler, Barbel
    Michalke, Bernhard
    JOURNAL OF TRACE ELEMENTS IN MEDICINE AND BIOLOGY, 2019, 56 : 207 - 212
  • [28] Uniting Native Capillary Electrophoresis and Multistage Ultraviolet Photodissociation Mass Spectrometry for Online Separation and Characterization of Escherichia coli Ribosomal Proteins and Protein Complexes
    Mehaffey, M. Rachel
    Xia, Qiangwei
    Brodbelt, Jennifer S.
    ANALYTICAL CHEMISTRY, 2020, 92 (22) : 15202 - 15211
  • [29] Mass spectrometry imaging of SOD1 protein-metal complexes in SOD1G93A transgenic mice implicates demetalation with pathology
    Hale, Oliver J.
    Wells, Tyler R.
    Mead, Richard J.
    Cooper, Helen J.
    NATURE COMMUNICATIONS, 2024, 15 (01)
  • [30] Denaturing and native top-down proteomics using capillary electrophoresis-tandem mass spectrometry
    Sun, Liangliang
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 258