Hyperspectral analysis for standoff detection of dimethyl methylphosphonate on building materials

被引:2
|
作者
Baseley, Daniel [1 ]
Wunderlich, Luke [2 ]
Phillips, Grady [3 ]
Gross, Kevin [3 ]
Perram, Glen [3 ]
Willison, Stuart [4 ]
Phillips, Rebecca [4 ]
Magnuson, Matthew [4 ]
Lee, Sang Don [4 ]
Harper, Willie F., Jr. [1 ]
机构
[1] US Air Force, Inst Technol, Dept Syst Engn & Management, 2950 Hobson Way, Wright Patterson AFB, OH 45433 USA
[2] Wright State Univ, Dept Biomed Engn, Dayton, OH 45435 USA
[3] US Air Force, Inst Technol, Dept Engn Phys, 2950 Hobson Way, Wright Patterson AFB, OH 45433 USA
[4] US EPA, Natl Homeland Secur Res Ctr, 26 W Martin Luther King Dr,Mailstop NG-16, Cincinnati, OH 45268 USA
关键词
Hyperspectral imaging; Organophosphate; Contrast angle; Surface analysis; Decontamination; PESTICIDES; SPECTRA; CONTAMINATION; EXPOSURES; HEALTH; CANCER; RISK; AIR;
D O I
10.1016/j.buildenv.2016.08.028
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Detecting organophosphates in indoor settings can greatly benefit from more efficient and faster methods of surveying large surface areas than conventional approaches, which sample small surface areas followed by extraction and analysis. This study examined a standoff detection technique utilizing hyperspectral imaging for analysis of building materials in near-real time. In this proof-of-concept study, dimethyl methylphosphonate (DMMP) was applied to stainless steel and laminate coupons and spectra were collected during active illumination. Absorbance bands at approximately 1275 cm(-1) and 1050 cm(-1) were associated with phosphorus-oxygen double bond (P=O) and phosphorus-oxygen-carbon (P-O-C) bond stretches of DMMP, respectively. The magnitude of these bands increased linearly (r(2) = 0.93) with DMMP across the full absorbance spectrum, between v(1) = 877 cm(-1) to v(2) = 1262 cm(-1). Comparisons between bare and contaminated surfaces on stainless steel using the spectral contrast angle technique indicated that the bare samples showed no sign of contamination, with large uniformly distributed contrast angles of 45 degrees-55 degrees, while the contaminated samples had smaller spectral contact angles of <20 degrees in the contaminated region and >40 degrees in the uncontaminated region. The laminate contaminated region exhibited contact angles of <25 degrees. To the best of our knowledge, this is the first report to demonstrate that hyperspectral imaging can be used to detect DMMP on building materials, with detection levels similar to concentrations expected for some organophosphate deposition scenarios. Published by Elsevier Ltd.
引用
收藏
页码:135 / 142
页数:8
相关论文
共 50 条
  • [21] New developments on standoff detection of explosive materials by differential reflectometry
    Schollhorn, Claus
    Fuller, Anna M.
    Gratier, Julien
    Hummel, Rolf E.
    CHEMICAL AND BIOLOGICAL SENSING VIII, 2007, 6554
  • [22] Infrared backscatter imaging spectroscopy for standoff detection of hazardous materials
    Finton, Drew M.
    Breshike, Christopher J.
    Kendziora, Christopher A.
    Furstenberg, Robert
    McGill, R. Andrew
    CHEMICAL, BIOLOGICAL, RADIOLOGICAL, NUCLEAR, AND EXPLOSIVES (CBRNE) SENSING XXIII, 2022, 12116
  • [23] Portable detection system for standoff sensing of explosives and hazardous materials
    Sharma, Ramesh C.
    Kumar, Deepak
    Bhardwaj, Neha
    Gupta, Saurabh
    Chandra, Hukum
    Maini, Anil K.
    OPTICS COMMUNICATIONS, 2013, 309 : 44 - 49
  • [24] Quantum Cascade Laser based active hyperspectral imaging for standoff detection of chemicals on surfaces
    Hugger, S.
    Fuchs, F.
    Jarvis, J.
    Yang, Q. K.
    Rattunde, M.
    Ostendorf, R.
    Schilling, C.
    Draid, R.
    Bronner, W.
    Aidam, R.
    Wagner, J.
    Tybussek, T.
    Rieblinger, K.
    QUANTUM SENSING AND NANO ELECTRONICS AND PHOTONICS XIII, 2016, 9755
  • [25] Nanosecond Gated Raman Spectroscopy for Standoff Detection of Hazardous Materials
    Chung, Jin Hyuk
    Cho, Soo Gyeong
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2014, 35 (12) : 3547 - 3552
  • [26] Threat detection using a standoff, wide-area hyperspectral Raman imaging sensor
    Gomer, Nathaniel R.
    Lamsal, Nirmal
    Sun, Haiyin
    Nelson, Matthew P.
    CHEMICAL, BIOLOGICAL, RADIOLOGICAL, NUCLEAR, AND EXPLOSIVES (CBRNE) SENSING XIX, 2018, 10629
  • [27] Passive standoff detection of RDX residues on metal surfaces via infrared hyperspectral imaging
    Thomas A. Blake
    James F. Kelly
    Neal B. Gallagher
    Paul L. Gassman
    Timothy J. Johnson
    Analytical and Bioanalytical Chemistry, 2009, 395 : 337 - 348
  • [28] Standoff detection and classification procedure for bioorganic compounds by hyperspectral laser-induced fluorescence
    Fischbach, Thomas
    Duschek, Frank
    Hausmann, Anita
    Pargmann, Carsten
    Aleksejev, Valeri
    Poryvkina, Larisa
    Sobolev, Innokenti
    Babichenko, Sergey
    Handke, Juergen
    CHEMICAL, BIOLOGICAL, RADIOLOGICAL, NUCLEAR, AND EXPLOSIVES (CBRNE) SENSING XVI, 2015, 9455
  • [29] The Effect of Density and Surface Area on Carbon Nanotube Capacitive Sensors for Dimethyl Methylphosphonate Detection
    Jing, Hong Jun
    Jiang, Ya Dong
    Du, Xiao Song
    MATERIALS SCIENCE AND NANOTECHNOLOGY I, 2013, 531-532 : 519 - 522
  • [30] Passive standoff detection of RDX residues on metal surfaces via infrared hyperspectral imaging
    Blake, Thomas A.
    Kelly, James F.
    Gallagher, Neal B.
    Gassman, Paul L.
    Johnson, Timothy J.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 395 (02) : 337 - 348