Speciation analysis of silver sulfide nanoparticles in environmental waters by magnetic solid-phase extraction coupled with ICP-MS

被引:29
|
作者
Zhou, Xiaoxia [1 ,2 ]
Liu, Jingfu [1 ,2 ]
Yuan, Chungang [3 ]
Chen, Yongsheng [4 ]
机构
[1] Chinese Acad Sci, Res Ctr Ecoenvironm Sci, State Key Lab Environm Chem & Ecotoxicol, Beijing 100085, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[3] North China Elect Power Univ, Sch Environm Sci & Engn, Baoding 071000, Peoples R China
[4] Georgia Inst Technol, Sch Civil & Environm Engn, Atlanta, GA 30332 USA
基金
美国国家科学基金会;
关键词
NATURAL ORGANIC-MATTER; CLOUD POINT EXTRACTION; ENGINEERED NANOPARTICLES; HUMIC-ACID; TOXICITY; SEPARATION; REMOVAL; PRECONCENTRATION; TRANSFORMATIONS; MICROSPHERES;
D O I
10.1039/c6ja00243a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The growing production and widespread application of silver nanoparticles (AgNPs) have led to their release into the environment, where they are mostly transformed to silver sulfide nanoparticles (Ag2S NPs). Thus, speciation analysis of Ag2S NPs in environmental matrices is essential for understanding the environmental process and toxic effects of AgNPs. Herein, we report the use of aged iron oxide magnetic particles (IOMPs) as magnetic solid-phase extraction adsorbents for speciation analysis of Ag2S NPs. It was found that IOMPs are excellent adsorbents for the selective extraction of silver-containing nanoparticles (AgCNPs) including Ag2S NPs, AgNPs and AgCl NPs in the presence of Ag+. More importantly, Ag2S NPs can be distinguished from the other AgCNPs by sequential elution. After pre-eluting AgNPs and AgCl NPs as Ag+ with 2% (v/v) acetic acid and IOMPs as the sacrificial oxidants, Ag2S NPs were completely eluted as a Ag(I) complex by 10 mM thiourea in 2% (v/v) acetic acid and quantified directly by inductively coupled plasma mass spectrometry (ICP-MS). While the extraction of Ag+ was negligible, the maximum extraction of AgCNPs by IOMPs was attained at pH 4.9-6.2, and the interference of humic acid in the AgCNP extraction can be efficiently eliminated by adding Ca2+. Under optimized conditions, the method provides low detection limit (0.068 mg L-1) and high reproducibility (relative standard deviations <5.1%) for Ag2S NPs. By simultaneously spiking 0.16-10.3 mg L-1 AgNPs and 0.53-14.8 mg L-1 Ag2S NPs, the Ag2S NP recoveries were in the range of 69.6-100.2% for the tap, river and lake waters; and in the range of 106.2-149.9% for the WWTP effluent due to the part sulfidation of AgNPs to Ag2S NPs. Our method is valid for the speciation analysis of Ag2S NPs in water samples, which provides an efficient approach for studying the sulfidation of AgNPs and Ag+.
引用
收藏
页码:2285 / 2292
页数:8
相关论文
共 50 条
  • [31] Analysis of methamphetamine in urine by GC/MS coupled with solid-phase dispersive extraction and solid-phase derivatization
    Saito, Koichi
    Segawa, Noriko
    Ito, Rie
    ANALYTICAL SCIENCES, 2025, 41 (01) : 85 - 92
  • [32] Determination of metal oxide nanoparticles and their ionic counterparts in environmental waters by size exclusion chromatography coupled to ICP-MS
    Zhou, Xiao-Xia
    Liu, Jing-Fu
    Geng, Fang-Lan
    NANOIMPACT, 2016, 1 : 13 - 20
  • [33] Simultaneous enrichment and speciation of lead and mercury by magnetic solid-phase extraction coupled to HPLC-ICP-MS based on magnetic hydrazine-linked covalent organic frameworks
    Zhang, Xiaolai
    Li, Fangli
    Chao, Jingbo
    Li, Zhicai
    Zhang, Guimin
    Zhai, Lihai
    Hu, Ligang
    Jiao, Heping
    Wang, Zhenhua
    ANALYTICA CHIMICA ACTA, 2024, 1307
  • [34] Reversible chelating polymer for determination of heavy metals by dispersive micro solid-phase extraction with ICP-MS
    Ahmad Rohanifar
    Niloofar Alipourasiabi
    Govind Sharma Shyam Sunder
    Joseph G. Lawrence
    Jon R. Kirchhoff
    Microchimica Acta, 2020, 187
  • [35] Determination of the Concentration and Isotope Ratio of Trace Lead in Lake Mashu by Solid-phase Extraction/ICP-MS
    Azumi, Suzuka
    Wada, Akari
    Sakagami, Hirotoshi
    Minami, Hirotsugu
    Fukazawa, Tatsuya
    Igarashi, Seiki
    Tanaka, Atsushi
    Takeuchi, Akinori
    Oyagi, Hideo
    Jin, Kazuo
    BUNSEKI KAGAKU, 2019, 68 (11) : 877 - 883
  • [36] Reversible chelating polymer for determination of heavy metals by dispersive micro solid-phase extraction with ICP-MS
    Rohanifar, Ahmad
    Alipourasiabi, Niloofar
    Shyam Sunder, Govind Sharma
    Lawrence, Joseph G.
    Kirchhoff, Jon R.
    MICROCHIMICA ACTA, 2020, 187 (06)
  • [37] Field-Flow Fractionation Coupled with ICP-MS for the Analysis of Engineered Nanoparticles in Environmental Samples
    Mitrano, Denise
    Ranville, James
    Neubauer, Ken
    Thomas, Robert
    SPECTROSCOPY, 2012, 27 (09) : 36 - 44
  • [38] Field-Flow Fractionation Coupled with ICP-MS for the Analysis of Engineered Nanoparticles in Environmental Samples
    Mitrano, Denise
    Renville, James
    Neubauer, Ken
    Thomas, Robert
    LC GC EUROPE, 2012, 25 (12) : 652 - +
  • [39] Fast and selective magnetic solid phase extraction of trace Cd, Mn and Pb in environmental and biological samples and their determination by ICP-MS
    Zhang, Nan
    Peng, Hanyong
    Wang, Shen
    Hu, Bin
    MICROCHIMICA ACTA, 2011, 175 (1-2) : 121 - 128
  • [40] Fast and selective magnetic solid phase extraction of trace Cd, Mn and Pb in environmental and biological samples and their determination by ICP-MS
    Nan Zhang
    Hanyong Peng
    Shen Wang
    Bin Hu
    Microchimica Acta, 2011, 175 : 121 - 128