In situ Microfluidic Cryofixation for Cryo Focused Ion Beam Milling and Cryo Electron Tomography

被引:20
|
作者
Fuest, Marie [1 ]
Schaffer, Miroslava [3 ]
Nocera, Giovanni Marco [1 ]
Galilea-Kleinsteuber, Rodrigo I. [1 ]
Messling, Jan-Erik [1 ]
Heymann, Michael [3 ,4 ]
Plitzko, Juergen M. [3 ]
Burg, Thomas P. [1 ,2 ]
机构
[1] Max Planck Inst Biophys Chem, Fassberg 11, D-37077 Gottingen, Germany
[2] Tech Univ Darmstadt, Merckstr 25, D-64283 Darmstadt, Germany
[3] Max Planck Inst Biochem, Klopferspitz 18, D-82152 Martinsried, Germany
[4] Univ Stuttgart, Inst Biomat & Biomol Syst, Pfaffenwaldring 57, D-70569 Stuttgart, Germany
基金
欧盟地平线“2020”;
关键词
SAMPLE PREPARATION; CORRELATIVE LIGHT; CRYOELECTRON MICROSCOPY; VITRIFICATION; TEMPERATURE; VISUALIZATION; LOCALIZATION; EXOCYTOSIS; SYSTEM; CELLS;
D O I
10.1038/s41598-019-55413-2
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
We present a microfluidic platform for studying structure-function relationships at the cellular level by connecting video rate live cell imaging with in situ microfluidic cryofixation and cryo-electron tomography of near natively preserved, unstained specimens. Correlative light and electron microscopy (CLEM) has been limited by the time required to transfer live cells from the light microscope to dedicated cryofixation instruments, such as a plunge freezer or high-pressure freezer. We recently demonstrated a microfluidic based approach that enables sample cryofixation directly in the light microscope with millisecond time resolution, a speed improvement of up to three orders of magnitude. Here we show that this cryofixation method can be combined with cryo-electron tomography (cryo-ET) by using Focused Ion Beam milling at cryogenic temperatures (cryo-FIB) to prepare frozen hydrated electron transparent sections. To make cryo-FIB sectioning of rapidly frozen microfluidic channels achievable, we developed a sacrificial layer technique to fabricate microfluidic devices with a PDMS bottom wall <5 mu m thick. We demonstrate the complete workflow by rapidly cryo-freezing Caenorhabditis elegans roundworms Ll larvae during live imaging in the light microscope, followed by cryo-FIB milling and lift out to produce thin, electron transparent sections for cryo-ET imaging. Cryo-ET analysis of initial results show that the structural preservation of the cryofixed C. elegans was suitable for high resolution cryo-ET work. The combination of cryofixation during live imaging enabled by microfluidic cryofixation with the molecular resolution capabilities of cryo-ET offers an exciting avenue to further advance space-time correlative light and electron microscopy (st-CLEM) for investigation of biological processes at high resolution in four dimensions.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Opening Windows into the Cell: Focused Ion Beam Micromachining of Eukaryotic Cells for Cryo-Electron Tomography
    Villa, Elizabeth
    Schaffer, Miroslava
    Rigort, Alexander
    Bauerlein, Felix
    Plitzko, Juergen
    Baumeister, Wolfgang
    BIOPHYSICAL JOURNAL, 2013, 104 (02) : 353A - 354A
  • [22] Integrative Approaches for Cellular Cryo-electron Tomography: Correlative Imaging and Focused Ion Beam Micromachining
    Rigort, Alexander
    Villa, Elizabeth
    Baeuerlein, Felix J. B.
    Engel, Benjamin D.
    Plitzko, Juergen M.
    CORRELATIVE LIGHT AND ELECTRON MICROSCOPY, 2012, 111 : 259 - 281
  • [23] Using focused-ion beam milling for cryo-electron tomography to understand cellular processes targeting bacterial cell membranes.
    Khanna, K.
    Wagner, F.
    Pogliano, K.
    Pogliano, J.
    Villa, E.
    MOLECULAR BIOLOGY OF THE CELL, 2015, 26
  • [24] Cryo-electron Microscopy Specimen Preparation By Means Of a Focused Ion Beam
    Rubino, Stefano
    Melin, Petter
    Spellward, Paul
    Leifer, Klaus
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2014, (89):
  • [25] Observation of whitening by cryo-focused ion beam scanning electron microscopy
    Matsushima, Hiroyuki
    Katsuki, Yoko
    Mukai, Koichiro
    Nagata, Mayumi
    Senoo, Tadashi
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (04): : 788 - 789
  • [26] Parallel cryo electron tomography on in situ lamellae
    Fabian Eisenstein
    Haruaki Yanagisawa
    Hiroka Kashihara
    Masahide Kikkawa
    Sachiko Tsukita
    Radostin Danev
    Nature Methods, 2023, 20 : 131 - 138
  • [27] Parallel cryo electron tomography on in situ lamellae
    Eisenstein, Fabian
    Yanagisawa, Haruaki
    Kashihara, Hiroka
    Kikkawa, Masahide
    Tsukita, Sachiko
    Danev, Radostin
    NATURE METHODS, 2023, 20 (01) : 131 - +
  • [28] Cryo-correlative light and electron microscopy workflow for cryo-focused ion beam milled adherent cells
    Klein, Steffen
    Wachsmuth-Melm, Moritz
    Winter, Sophie L.
    Kolovou, Androniki
    Chlanda, Petr
    CORRELATIVE LIGHT AND ELECTRON MICROSCOPY IV, 2021, 162 : 273 - 302
  • [29] A technique for improved focused ion beam milling of cryo-prepared life science specimens
    Hayles, M. F.
    Stokes, D. J.
    Phifer, D.
    Findlay, K. C.
    JOURNAL OF MICROSCOPY, 2007, 226 (03) : 263 - 269
  • [30] Cryo-focused-ion-beam applications in structural biology
    Rigort, Alexander
    Plitzko, Juergen M.
    ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 2015, 581 : 122 - 130