Behaviour of CFST slender columns strengthened with steel tube and sandwiched concrete jackets under axial loading

被引:19
|
作者
Huang, Yue [1 ]
Li, Weijie [2 ]
Lu, Yiyan [1 ]
Liang, Hongjun [1 ]
Yan, Yuhong [1 ]
机构
[1] Wuhan Univ, Sch Civil Engn, Wuhan 430072, Peoples R China
[2] Tsinghua Univ, Dept Civil Engn, Beijing 100084, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Optimal strengthening method; Slenderness; Concrete-filled steel tube; Steel tube and sandwiched concrete jackets; Intermediate-length columns; TUBULAR COLUMNS; STUB COLUMNS; DIAPHRAGM CONNECTIONS; PERFORMANCE; DESIGN;
D O I
10.1016/j.jobe.2021.103613
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A strengthening method for slender concrete-filled steel tube (CFST) columns using a steel tube and sandwiched concrete jackets was investigated. The strengthening decreases the member slenderness owing to the enlarged cross section, which is beneficial for avoiding instability problems. The effect of the variation in slenderness ratio on the different strengthening parameters was evaluated, and the optimal strengthening strategies for stub, slender and long columns were suggested. The experimental parameters included the length-to-diameter ratio, diameter-to thickness ratio, and sandwiched concrete strength. All specimens tested in this study were intermediate-length columns. The results indicate that the limiting value of the length-to-diameter ratio between intermediate-length and long columns is slightly larger than 10.0. For intermediate length columns, thicker outer steel tubes are more effective than high-grade sandwiched concrete. A finite-element model was then developed using ABAQUS, considering both intermediate length and long retrofitted columns. The differences between the two types of columns were analysed based on the loads on each component. Additionally, a parametric analysis was conducted to determine the effects of the strengthening parameters, including the outer steel tube strength, and damages to the inner column on the capacity after strengthening. The relationship between the reduction factor related to the length and confinement index was then presented. Finally, a model for calculating the load-bearing capacity of slender strengthened columns was proposed.
引用
收藏
页数:22
相关论文
共 50 条
  • [21] Behaviour of CFRP-confined concrete-filled circular steel tube stub columns under axial loading
    Ding, Fa-xing
    Lu, De-ren
    Bai, Yu
    Gong, Yong-zhi
    Yu, Zhi-wu
    Ni, Ming
    Li, Wei
    THIN-WALLED STRUCTURES, 2018, 125 : 107 - 118
  • [22] Experimental Study on the Axial Loading Tests of RC Columns Strengthened with Steel Tube
    Zhou, Miao
    Li, Jianwei
    Duan, Jingmin
    PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING, PTS. 1-5, 2012, 204-208 : 2878 - +
  • [23] Influence of steel tube thickness and concrete strength on the axial capacity of stub CFST columns
    Ibanez, C.
    Hernandez-Figueirido, D.
    Piquer, A.
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON ADVANCES IN STEEL-CONCRETE COMPOSITE STRUCTURES (ASCCS 2018), 2018, : 253 - 257
  • [24] Circular reinforced concrete columns strengthened by combined square steel tube and concrete jackets subjected to eccentric load
    Yan, Yuhong
    Li, Shan
    Huang, Yue
    Lu, Yiyan
    Zhao, Xiaobo
    ENGINEERING STRUCTURES, 2024, 320
  • [25] Analysis on Behavior of Square RC Columns Strengthened with Concrete Filled Steel Tube Under Axial Load
    Yin X.
    Liang H.
    Lu Y.
    Li N.
    Yingyong Jichu yu Gongcheng Kexue Xuebao/Journal of Basic Science and Engineering, 2022, 30 (03): : 566 - 578
  • [26] Size effect of square steel tube and sandwiched concrete jacketed circular RC columns under axial compression
    Zhao, Xiaobo
    Liang, Hongjun
    Lu, Yiyan
    Zhao, Pengtuan
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 166
  • [27] Axially loaded square CFST short columns strengthened with high-strength square steel tubes and concrete jackets
    Ma, Wentao
    Yan, Yuhong
    Lu, Yiyan
    Li, Shan
    Wang, Linzi
    ENGINEERING STRUCTURES, 2025, 324
  • [28] Behaviour of FRP strengthened concrete columns under eccentric compression loading
    Hadi, M. N. S.
    COMPOSITE STRUCTURES, 2007, 77 (01) : 92 - 96
  • [29] Slender RC columns strengthened with combined CFRP and steel jacket under axial load
    Lu, Yi-yan
    Li, Na
    Li, Shan
    Ou, Tian-yan
    STEEL AND COMPOSITE STRUCTURES, 2015, 19 (05): : 1077 - 1094
  • [30] EXPERIMENTAL STUDY ON STEEL CHS SLENDER COLUMNS STRENGTHENED BY CFRP UNDER AXIAL COMPRESSION
    Wan, Haiying
    Feng, Ran
    Peng, Jun
    STEEL AND ALUMINIUM STRUCTURES, 2016,