Novel Model for Analysis and Optimization of Silicon Photomultiplier-Based Scintillation Systems

被引:2
|
作者
Sommer, Marek [1 ,2 ]
Krist, Pavel [1 ]
Kakona, Martin [1 ]
Ploc, Ondrej [1 ]
机构
[1] Czech Acad Sci, Nucl Phys Inst, Husinec 25068, Czech Republic
[2] Czech Tech Univ, Fac Nucl Sci & Phys Engn, Prague 11519, Czech Republic
关键词
Scintillators; Photonics; Shape; Microcell networks; Silicon; Photomultipliers; Analytical models; Monte Carlo methods; pulse shape discrimination (PSD); scintillators; silicon photomultiplier (SiPM); PULSE-SHAPE DISCRIMINATION; SIPM-ARRAY; DETECTOR;
D O I
10.1109/TNS.2021.3121871
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Nowadays, silicon photomultipliers (SiPMs) are extensively used for absorption of scintillation light in all types of scintillators in high-energy physics. Fast spread of SiPMs resulted in a rapid development of both analytical and Monte Carlo models. Models describe the response of these silicon integrated circuits. We introduce a novel Monte Carlo model of SiPM with a scintillator module that enables modeling the response of SiPM to dynamic scintillation processes. The model introduces several improvements over other models. This article focuses on the analysis of pulse shape discrimination (PSD) performance of SiPM-based scintillation systems since such techniques are often used to discriminate between incident particles of ionizing radiation. The algorithms for PSD are sensitive to the shape of the pulse and SiPMs have several mechanisms that influence the shape of the output pulse, such as bandwidth of the system, the presence of fast decay components, and the recovery time of individual microcells. Some of these mechanisms are not present in a classical photomultiplier, for instance, a recovery time or the fast decay component. We have analyzed the performance of three different PSD algorithms with three SiPMs (MicroFC-30020, MicroFC-30035, and MicroFC-30050) coupled with scintillators EJ-301 and EJ-276. Several conclusions are drawn from the analysis. The two most important ones are that optimized systems need to finetune their bandwidth and that scintillators with fast decay signals are better suited for photomultipliers with lower recovery time and vice versa. It is also shown that the classical charge comparison algorithm does not reach the performance of modern algorithms, for instance, frequency gradient analysis.
引用
收藏
页码:2771 / 2778
页数:8
相关论文
共 50 条
  • [41] Advanced Study of Novel Radiation Detector based on Silicon Photomultiplier
    Osovizky, Alon
    Ginzburg, Dimitry
    Ghelman, Max
    Cohen-Zada, Ilan
    Pushkarsky, Vitaly
    Marcus, Eli
    Manor, Avi
    Kadmon, Yagil
    Cohen, Yosef
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 1552 - +
  • [42] PET performance as a function of axial field of view for a new silicon photomultiplier-based whole body TOF PET/CT system
    Levin, Craig
    Peterson, William
    Ross, Steven
    Stearns, Charles
    Uribe, Jorge
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [43] Timing optimization of a H-tree based digital silicon photomultiplier
    Mandai, S.
    Charbon, E.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [44] A Sensitive Fluorescence Analysis Method of Pathogenic Microorganisms Based on Silicon Photomultiplier
    Chen, Yi
    Dai, Licheng
    Zhang, Fei
    Zhao, Tianqi
    Jin, Shangzhong
    JOURNAL OF FLUORESCENCE, 2024,
  • [45] Quantification performance of silicon photomultiplier-based PET for small 18F-, 68Ga- and 124I-avid lesions in the context of radionuclide therapy planning
    Kersting, David
    Moraitis, Alexandros
    Sraieb, Miriam
    Zarrad, Fadi
    Umutlu, Lale
    Rischpler, Christoph
    Fendler, Wolfgang Peter
    Herrmann, Ken
    Weber, Manuel
    Conti, Maurizio
    Costa, Pedro Fragoso
    Jentzen, Walter
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 114
  • [46] OPTIMIZATION OF SCINTILLATION DETECTOR TIMING SYSTEMS USING MONTE-CARLO ANALYSIS
    BINKLEY, DM
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (01) : 386 - 393
  • [47] A linear model for water systems design based on optimization and reliability analysis
    Guercio, R
    Ferrante, M
    3RD INTERNATIONAL CONFERENCE ON WATER PIPELINE SYSTEMS: LEAKAGE MANAGEMENT, NETWORK OPTIMIZATION, AND PIPELINE REHABILITATION TECHNOLOGY, 1997, (23): : 221 - 227
  • [48] Time-resolved single-photon detection module based on silicon photomultiplier: A novel building block for time-correlated measurement systems
    Martinenghi, E.
    Di Sieno, L.
    Contini, D.
    Sanzaro, M.
    Pifferi, A.
    Dalla Mora, A.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (07):
  • [49] A novel optimization model based on game tree for multi-energy conversion systems
    Huang, Zishuo
    Yu, Hang
    Chu, Xiangyang
    Peng, Zhenwei
    ENERGY, 2018, 150 : 109 - 121
  • [50] DESIGN OF NOVEL COMPACT DETECTOR BASED ON THE BISMUTH GERMANATE SCINTILLATOR AND SILICON PHOTOMULTIPLIER FOR ORTHO-POSITRONIUM PHYSICS
    Park, HyeoungWoo
    Jung, D. W.
    Hwang, Sanghoon
    Kim, H. J.
    ACTA PHYSICA POLONICA B, 2020, 51 (01): : 143 - 148