Pachymetric measurements with a new Scheimpflug photography-based system Intraobserver repeatability and agreement with optical coherence tomography pachymetry

被引:67
|
作者
Milla, Myriam [1 ]
Pinero, David P. [1 ,2 ]
Amparo, Francisco [1 ]
Alio, Jorge L. [1 ,3 ]
机构
[1] Vissum Corp, Inst Oftalmol Alicante, Alicante 03016, Spain
[2] Univ Alicante, Dept Opt, E-03080 Alicante, Spain
[3] Univ Miguel Hernandez, Div Ophthalmol, Alicante, Spain
来源
关键词
CORNEAL THICKNESS MEASUREMENTS; IN-SITU KERATOMILEUSIS; ULTRASOUND PACHYMETRY; ANTERIOR SEGMENT; OCULUS-PENTACAM; ORBSCAN-II; REPRODUCIBILITY; VISANTE; TOPOGRAPHY; MYOPIA;
D O I
10.1016/j.jcrs.2010.08.038
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the intraobserver repeatability of pachymetric measurements obtained with a new Scheimpflug photography-based system and the agreement of the measurements with those obtained by optical coherence tomography (OCT). SETTING: Vissum Corporation, Alicante, Spain. DESIGN: Evaluation of diagnostic technology. METHODS: Corneal thickness was measured at different locations (center; 2.5 mm and 4.0 mm nasal, temporal, superior, and inferior) in 18 eyes of 18 patients with no ocular pathology or previous surgery with a Scheimpflug photography-based system (Sirius). Three consecutive measurements at each location were obtained with the system to evaluate intraobserver repeatability. Afterward, pachymetric measurements were obtained at the same locations with an OCT system (Visante) to evaluate the agreement between techniques using the Bland-Altman method. RESULTS: The intraclass correlation coefficient of repeated measures ranged from 0.990 to 0.997. The coefficient of variation was lower than 1% and the standard deviations of the repeated measurements (S-w) were below 6 mu m at all corneal locations. Statistically significant differences were found between the coefficient of variation and S-w, values of the repeated measurements corresponding to the 2.5 mm and 4.0 mm locations (P <=.037). The agreement with OCT pachymetric measurements was poor, with ranges of agreement larger than 20 mu m at all corneal locations. Statistically significant differences were found between standard deviations of the differences between the 2 devices at the 2.5 mm and 4.0 mm locations (P <=.017). CONCLUSION: Scheimpflug photography-based technology provided repeatable pachymetric measurements that were not equivalent to those obtained with OCT.
引用
收藏
页码:310 / 316
页数:7
相关论文
共 50 条
  • [21] Comparison of central corneal thickness measurements in corneal edema using ultrasound pachymetry, Visante anterior-segment optical coherence tomography, Cirrus optical coherence tomography, and Pentacam Scheimpflug camera tomography
    Wongchaisuwat, Nida
    Metheetrairat, Ankana
    Chonpimai, Pratuangsri
    Nujoi, Waree
    Prabhasawat, Pinnita
    CLINICAL OPHTHALMOLOGY, 2018, 12 : 1865 - 1873
  • [22] Agreement between optical coherence and Scheimpflug tomography: Vault measurements and reproducibility after implantable collamer lens implantation
    Almorin-Fernandez-Vigo, I.
    Sanchez-Guillen, I.
    Fernandez-Vigo, J. I.
    De-Pablo-Gomez-De-Liano, L.
    Kudsieh, B.
    Fernandez-Vigo, J. A.
    Macarro-Merino, A.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2021, 44 (09): : 1370 - 1380
  • [23] Repeatability and Agreement of Optical Coherence Tomography Measurements Obtained with the Spectralis OCT2 and the New Spectralis OCT3
    Tsukikawa, Mai
    Jammal, Alessandro A.
    Tseng, Henry
    Medeiros, Felipe
    Asrani, Sanjay
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [24] Comparison of corneal tomography using a novel swept-source optical coherence tomographer and rotating Scheimpflug system in normal and keratoconus eyes: repeatability and agreement analysis
    Herber, Robert
    Lenk, Janine
    Pillunat, Lutz E.
    Raiskup, Frederik
    EYE AND VISION, 2022, 9 (01)
  • [25] Comparison of corneal tomography using a novel swept-source optical coherence tomographer and rotating Scheimpflug system in normal and keratoconus eyes: repeatability and agreement analysis
    Robert Herber
    Janine Lenk
    Lutz E. Pillunat
    Frederik Raiskup
    Eye and Vision, 9
  • [26] Comparison of Anterior Segment Measurements between Scheimpflug Camera and New Module of Optical Coherence Tomography
    Kim, Jae Min
    Kang, Min Seok
    Jin, Kyung Hyun
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2018, 59 (07): : 613 - 621
  • [27] Intra-examiner repeatability and agreement of corneal pachymetry map measurement by time-domain and Fourier-domain optical coherence tomography
    Jehn-Yu Huang
    Melike Pekmezci
    Stephanie Yaplee
    Shan Lin
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2010, 248 : 1647 - 1656
  • [28] Intraobserver repeatability and interobserver reproducibility of corneal measurements in normal eyes using an optical coherence tomography-Placido disk device
    Shah, Jinesh M.
    Han, Daphne
    Htoon, Hla Myint
    Mehta, Jodhbir S.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (02): : 372 - 381
  • [29] Intra-examiner repeatability and agreement of corneal pachymetry map measurement by time-domain and Fourier-domain optical coherence tomography
    Huang, Jehn-Yu
    Pekmezci, Melike
    Yaplee, Stephanie
    Lin, Shan
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (11) : 1647 - 1656
  • [30] Intraobserver repeatability of automated versus adjusted optical coherence tomography measurements in patients with neovascular age-related macular degeneration
    Tatlipinar, Sinan
    Shah, Syed Mahmood
    Campochiaro, Peter A.
    Nguyen, Quan Dong
    OPHTHALMOLOGICA, 2007, 221 (04) : 227 - 232