Simultaneous determination of sphingosine and sphingosine 1-phosphate in biological samples by liquid chromatography-tandem mass spectrometry

被引:31
|
作者
Lan, Tian [1 ]
Bi, Huichang [2 ]
Liu, Weihua [1 ]
Xie, Xi [1 ]
Xu, Suowen [1 ]
Huang, Heqing [1 ]
机构
[1] Sun Yat Sen Univ, Lab Pharmacol & Toxicol, Sch Pharmaceut Sci, Guangzhou Higher Educ Mega Ctr, Guangzhou 510006, Guangdong, Peoples R China
[2] Sun Yat Sen Univ, Lab Drug Metab & Pharmacokinet, Sch Pharmaceut Sci, Guangzhou 510006, Guangdong, Peoples R China
关键词
Sphingosine; 1-phosphate; C17-sphingosine; Simultaneous determination; Liquid chromatography-tandem mass spectrometry (LC-MS/MS); QUANTITATIVE-ANALYSIS; SHOTGUN LIPIDOMICS; CRUDE EXTRACTS; PLASMA SAMPLES; LC-MS/MS; KINASE; SPHINGOSINE-1-PHOSPHATE; DERIVATIZATION; HPLC; SPHINGOLIPIDS;
D O I
10.1016/j.jchromb.2011.01.015
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
D-erythro-sphingosine (Sph) and its phosphorylated product, D-erythro-sphingosine 1-phosphate (S1P) are sphingolipids mediating numerous cellular processes. Imbalance of Sph/S1P levels contributes to many diseases. Given the interconversion of these two opposing signaling molecules, it is essential to examine their levels simultaneously. In the present study, we developed a rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to simultaneously quantify the levels of Sph and SIP in biological samples using C17-Sph and C17-S1P as internal standards. With one step of methanol-induced protein precipitation, each sample was subjected to LC-MS/MS analysis using positive electrospray ionization under selected reaction monitoring mode. The running time was within 4 min with a simple mobile phase consisting of methanol-0.1% formic acid (95:5, v/v) at a flow rate of 0.2 mL/min. Standard curves were linear over ranges of 1-100 ng/mL for Sph and 0.1-10 ng/mL for SI P with correlation coefficient (r(2)) greater than 0.997. The lower limit of quantifications (LLOQs) were 1 ng/mL for Sph and 0.1 ng/mL for Si P. The intra-batch and inter-batch precision was less than 15% for all quality control samples. The recoveries of the method were found to be 76.36-89.84%. The method was applied to simultaneously determine the Sph and S1P levels in mouse kidney, human plasma, and HEK 293 cells treated with tumor necrosis factor-alpha (TNF-alpha) and N,N-dimethylsphingosine (DMS). The S1P levels increased in cells treated with TNF-alpha whereas decreased in cells treated with DMS. These results indicated that this new LC-MS/MS method was rapid, sensitive, specific and reliable to quantify Sph and SIP levels in biological samples simultaneously. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:520 / 526
页数:7
相关论文
共 50 条
  • [41] Simultaneous Determination of Seven Mental Drugs in Feeds by Liquid Chromatography-Tandem Mass Spectrometry
    Suo De-Cheng
    Zhao Gen-Long
    Li Lan
    Su Xiao-Ou
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (07) : 1023 - 1026
  • [42] Simultaneous determination of seven flavonoids in Epimedium by liquid chromatography-tandem mass spectrometry method
    Cai Sheng Wu~a Bao Lin Guo~b YU Xin Sheng~a Jin Lan Zhang~(a
    Chinese Chemical Letters, 2008, (03) : 329 - 332
  • [43] Simultaneous determination of methylephedrine and noscapine in human plasma by liquid chromatography-tandem mass spectrometry
    Zhu, L
    Chen, XY
    Zhang, YF
    Yu, HL
    Zhong, DF
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 820 (02): : 175 - 182
  • [44] Determination of denaverine and its metabolites in urine samples by liquid chromatography-tandem mass spectrometry
    Kilian, B.
    Oertel, R.
    Kirch, W.
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1189 (1-2) : 339 - 346
  • [45] Determination of scopolamine in human serum and microdialysis samples by liquid chromatography-tandem mass spectrometry
    Oertel, R
    Richter, K
    Ebert, U
    Kirch, W
    JOURNAL OF CHROMATOGRAPHY B, 2001, 750 (01): : 121 - 128
  • [46] Simultaneous determination of chlorpheniramine and pseudoephedrine in human plasma by liquid chromatography-tandem mass spectrometry
    Chen, XY
    Zhang, Y
    Zhong, DF
    BIOMEDICAL CHROMATOGRAPHY, 2004, 18 (04) : 248 - 253
  • [47] Simultaneous determination of plasma total homocysteine and methionine by liquid chromatography-tandem mass spectrometry
    Jiang, Yi
    Mistretta, Brandon
    Elsea, Sarah
    Sun, Qin
    CLINICA CHIMICA ACTA, 2017, 464 : 93 - 97
  • [48] Simultaneous determination of androstenedione and testosterone in human serum by liquid chromatography-tandem mass spectrometry
    Gallagher, L. M.
    Owen, L. J.
    Keevil, B. G.
    ANNALS OF CLINICAL BIOCHEMISTRY, 2007, 44 : 48 - 56
  • [49] Simultaneous determination of six urinary porphyrins using liquid chromatography-tandem mass spectrometry
    Bu, W
    Myers, N
    McCarty, JD
    O'Neill, T
    Hollar, S
    Stetson, PL
    Sved, DW
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 783 (02): : 411 - 423
  • [50] Simultaneous determination of acidic pesticides in vegetables and fruits by liquid chromatography-tandem mass spectrometry
    Shida, Shizuka S.
    Nemoto, Satoru
    Matsuda, Rieko
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART B-PESTICIDES FOOD CONTAMINANTS AND AGRICULTURAL WASTES, 2015, 50 (03) : 151 - 162