Simultaneous determination of sphingosine and sphingosine 1-phosphate in biological samples by liquid chromatography-tandem mass spectrometry

被引:31
|
作者
Lan, Tian [1 ]
Bi, Huichang [2 ]
Liu, Weihua [1 ]
Xie, Xi [1 ]
Xu, Suowen [1 ]
Huang, Heqing [1 ]
机构
[1] Sun Yat Sen Univ, Lab Pharmacol & Toxicol, Sch Pharmaceut Sci, Guangzhou Higher Educ Mega Ctr, Guangzhou 510006, Guangdong, Peoples R China
[2] Sun Yat Sen Univ, Lab Drug Metab & Pharmacokinet, Sch Pharmaceut Sci, Guangzhou 510006, Guangdong, Peoples R China
关键词
Sphingosine; 1-phosphate; C17-sphingosine; Simultaneous determination; Liquid chromatography-tandem mass spectrometry (LC-MS/MS); QUANTITATIVE-ANALYSIS; SHOTGUN LIPIDOMICS; CRUDE EXTRACTS; PLASMA SAMPLES; LC-MS/MS; KINASE; SPHINGOSINE-1-PHOSPHATE; DERIVATIZATION; HPLC; SPHINGOLIPIDS;
D O I
10.1016/j.jchromb.2011.01.015
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
D-erythro-sphingosine (Sph) and its phosphorylated product, D-erythro-sphingosine 1-phosphate (S1P) are sphingolipids mediating numerous cellular processes. Imbalance of Sph/S1P levels contributes to many diseases. Given the interconversion of these two opposing signaling molecules, it is essential to examine their levels simultaneously. In the present study, we developed a rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to simultaneously quantify the levels of Sph and SIP in biological samples using C17-Sph and C17-S1P as internal standards. With one step of methanol-induced protein precipitation, each sample was subjected to LC-MS/MS analysis using positive electrospray ionization under selected reaction monitoring mode. The running time was within 4 min with a simple mobile phase consisting of methanol-0.1% formic acid (95:5, v/v) at a flow rate of 0.2 mL/min. Standard curves were linear over ranges of 1-100 ng/mL for Sph and 0.1-10 ng/mL for SI P with correlation coefficient (r(2)) greater than 0.997. The lower limit of quantifications (LLOQs) were 1 ng/mL for Sph and 0.1 ng/mL for Si P. The intra-batch and inter-batch precision was less than 15% for all quality control samples. The recoveries of the method were found to be 76.36-89.84%. The method was applied to simultaneously determine the Sph and S1P levels in mouse kidney, human plasma, and HEK 293 cells treated with tumor necrosis factor-alpha (TNF-alpha) and N,N-dimethylsphingosine (DMS). The S1P levels increased in cells treated with TNF-alpha whereas decreased in cells treated with DMS. These results indicated that this new LC-MS/MS method was rapid, sensitive, specific and reliable to quantify Sph and SIP levels in biological samples simultaneously. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:520 / 526
页数:7
相关论文
共 50 条
  • [1] Determination of sphingosine kinase activity in biological samples by liquid chromatography-tandem mass spectrometry
    Lan, Tian
    Bi, Huichang
    Xu, Suowen
    Le, Kang
    Xie, Zhiyong
    Liu, Yiwei
    Huang, Heqing
    BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (10) : 1075 - 1083
  • [2] High-Throughput Analysis of Sphingosine 1-Phosphate, Sphinganine 1-Phosphate, and Lysophosphatidic Acid in Plasma Samples by Liquid Chromatography-Tandem Mass Spectrometry
    Scherer, Max
    Schmitz, Gerd
    Liebisch, Gerhard
    CLINICAL CHEMISTRY, 2009, 55 (06) : 1218 - 1222
  • [3] Analysis of sphingomyelin, glucosylceramide, ceramide, sphingosine, and sphingosine 1-phosphate by tandem mass spectrometry
    Sullards, MC
    SPHINGOLIPID METABOLISM AND CELL SIGNALING, PT B, 2000, 312 : 32 - 45
  • [4] Preanalytical standardization of sphingosine-1-phosphate, sphinganine-1-phosphate and sphingosine analysis in human plasma by liquid chromatography-tandem mass spectrometry
    Ceglarek, Uta
    Dittrich, Julia
    Helmschrodt, Christin
    Wagner, Kristin
    Nofer, Jerzy-Roch
    Thiery, Joachim
    Becker, Susen
    CLINICA CHIMICA ACTA, 2014, 435 : 1 - 6
  • [5] Determination of Global DNA Methylation in Biological Samples by Liquid Chromatography-Tandem Mass Spectrometry
    Peng Si-Yuan
    Zhang Jie
    Tian Mei-Ping
    Wang Zhan-Lin
    Shen He-Qing
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 40 (08) : 1201 - 1206
  • [6] Determination of corticosteroids in tissue samples by liquid chromatography-tandem mass spectrometry
    Rönquist-Nii, Y
    Edlund, PO
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 37 (02) : 341 - 350
  • [7] Highly sensitive determination of saquinavir in biological samples using liquid chromatography-tandem mass spectrometry
    Burhenne, J
    Riedel, KD
    Martin-Facklam, M
    Mikus, G
    Haefeli, WE
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 784 (02): : 233 - 242
  • [8] Signaling and biological actions of sphingosine 1-phosphate
    Hla, T
    PHARMACOLOGICAL RESEARCH, 2003, 47 (05) : 401 - 407
  • [9] Simultaneous analysis of antibiotics in biological samples by ultra high performance liquid chromatography-tandem mass spectrometry
    Cazorla-Reyes, Rocio
    Romero-Gonzalez, Roberto
    Garrido Frenich, Antonia
    Rodriguez Maresca, Manuel Angel
    Martinez Vidal, Jose Luis
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 89 : 203 - 212
  • [10] Biological effects of sphingosine 1-phosphate on keratinocytes
    Nishijima, T
    Kitahara, T
    Takema, Y
    JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2002, 119 (03) : 746 - 746