PCI Using a 4-Fr "Child" Guide Catheter in a "Mother" Guide Catheter: Kyushu KIWAMI® ST Registry

被引:5
|
作者
Hiwatashi, Atsushi [1 ]
Iwabuchi, Masashi [1 ]
Yokoi, Hiroyoshi [1 ]
Tayama, Shinji [2 ]
Sakamoto, Tomohiro [2 ]
Noda, Katsuo [3 ]
Shibata, Yoshisato [4 ]
Hikichi, Yutaka [5 ]
Node, Koichi [5 ]
Ueno, Takafumi [6 ]
Nobuyoshi, Masakiyo [1 ]
机构
[1] Kokura Mem Hosp, Dept Cardiol, Fukuoka, Japan
[2] Saiseikai Kumamoto Hosp, Dept Cardiol, Kumamoto, Japan
[3] Kumamoto City Hosp, Dept Cardiol, Kumamoto, Japan
[4] Miyazaki Med Assoc Hosp, Dept Cardiol, Miazaki, Japan
[5] Saga Univ, Fac Med, Dept Cardiovasc & Renal Med, Saga 840, Japan
[6] Kurume Univ, Sch Med, Div Cardiovasc Med, Dept Internal Med, Fukuoka, Japan
关键词
percutaneous coronary intervention (PCI); anomalous coronaries (ANOM); transradial cath (TRAD); STENT DELIVERY;
D O I
10.1002/ccd.22741
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: With the development of PCI techniques, the indications for stents have been expanding as well. On the other hand, we often encounter the situations where deploying a stent/stents by the conventional method is technically challenging. We report a novel stent delivery system using a newly developed 4Fr. straight catheter with Mother-and-Child method. Methods and results: We collected the data on coronary angioplasty in which we experienced the difficulty to deliver coronary stents and used 4Fr. KIWAMI ST01. The case number amounts to 32 cases over a six-month period from October 2009 through March 2010. The angioplasty was performed for lesions in the RCA in 9 patients (28%), lesions in the LAD in 15 patients (47%), lesions in the LCX in 5 patients (16%), lesions in the saphenous vein grafts in 2 patients (6%), and lesions in the internal thoracic artery (LITA) grafts in 1 patient (3%). And the reasons for the difficult stent delivery by the conventional methods were as follows: severe calcification in 12 patients (37%), intense tortuosity in 7 patients (22%), poor backup support for guide catheter in 8 patients (25%), and trapping of the stent proximal to the target lesion in 5 patients (16%). The dislodgment of stent did not happened in all cases. Conclusions: KIWAMI (R) ST01 stent delivery system is feasible, safer, and effective in cases where stent delivery is difficult by the conventional method. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:919 / 923
页数:5
相关论文
共 29 条
  • [21] Mother-and-Child Telescopic Guide-Catheter Extension to Identify Severe Left Main Stem Disease in a Patient With a Severely Dilated Aortic Root
    Williams, Rupert
    Shouls, Genevieve
    Firoozi, Sami
    JOURNAL OF INVASIVE CARDIOLOGY, 2018, 30 (08): : E71 - E72
  • [22] Coronary Perforation in a Patient with ST Elevation Myocardial Infarction Treated by Stent Graft Implantation Using the Double Guide Catheter (Ping Pong) Technique
    Naghshtabrizi, Behshad
    Mozayanimonfared, Azadeh
    Karimi-Akhormeh, Ali
    Hosseini, Seyed Kianoosh
    INTERNATIONAL CARDIOVASCULAR RESEARCH JOURNAL, 2022, 16 (02) : 85 - 88
  • [23] High Risk PCI in a Patient With Triple Vessel Disease and Left Main Lesion: How to Overcome Challenges to Rewire the Side Branch by Using Guide Extension Catheter
    Nay Thu Win
    Ting Yuen Beh
    Ganesan, Kumara Gurupparan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (15) : S135 - S137
  • [24] A randomized comparison of frequency of radial artery occlusion and radial artery spasm associated with TRI Using 6.5-Fr Sheathless Guide Catheter vs. 6.0-Fr Glidesheath Slender
    Horie, K.
    Tada, N.
    Isawa, T.
    Matsumoto, T.
    Honda, T.
    Otomo, T.
    Inoue, N.
    EUROPEAN HEART JOURNAL, 2017, 38 : 678 - 678
  • [25] Successful aspiration thrombectomy of an 80-mm-long thrombus using a guide extension catheter in a patient with ST-elevation acute myocardial infarction
    Numasawa, Yohei
    Himeno, Yukihiro
    Yokokura, Souichi
    Haginiwa, Sho
    Kojima, Hidenori
    Tanaka, Makoto
    CARDIOVASCULAR INTERVENTION AND THERAPEUTICS, 2025, 40 (01) : 182 - 183
  • [26] Slender Pci by Using a 5f Guide Catheter via Radial Artery in Bangladeshi Stent Era-a Pilot Study at Apollo Hospitals Dhaka.
    Islam, Ahm Waliul
    Munwar, Shams
    Talukder, Shahabuddin
    Reza, A. Q. M.
    Ahmed, Tamzeed
    Bhuiyan, Azfar H.
    AMERICAN JOURNAL OF CARDIOLOGY, 2013, 111 (07): : 78B - 78B
  • [27] Transradial Intervention in Patients With Non-ST Elevation Acute Coronary Syndrome Using One 4.0 Fr Sheath and One Sheathless Guide Catheter Via a Single Puncture Site: The 1-1-1 Strategy
    Horie, Kazunori
    Tada, Norio
    Isawa, Tsuyoshi
    Matsumoto, Takashi
    Taguri, Masataka
    Kato, Shigeaki
    Honda, Taku
    Ootomo, Tatsushi
    Inoue, Naoto
    JOURNAL OF INVASIVE CARDIOLOGY, 2018, 30 (09): : 316 - 323
  • [28] Transradial diagnostic and therapeutic coronary catheterization for patients with NSTEMI or UAP using one 4.0-Fr sheath and one Sheathless Eaucathe guide catheter via one puncture site: 1-1-1 Trial
    Horie, Kazunori
    Tada, Norio
    Tsuyoshi, Isawa
    Matsumoto, Takashi
    Honda, Taku
    Ohtomo, Tatsushi
    Inoue, Naoto
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (18) : B148 - B149
  • [29] Transradial diagnostic and therapeutic coronary catheterization of patients with non-st-segment elevation ACS using one sheath and one sheathless guide catheter via one puncture site: the 1-1-1 strate
    Horie, K.
    Tada, N.
    Isawa, T.
    Matsumoto, T.
    Honda, T.
    Otomo, T.
    Inoue, N.
    EUROPEAN HEART JOURNAL, 2017, 38 : 998 - 998