Radiological shielding considerations for the first optics enclosures of the Canadian light source

被引:7
|
作者
Asai, J
Hirayama, H
机构
[1] Univ Saskatchewan, Canadian Light Source Inc, Saskatoon, SK S7N 0X4, Canada
[2] High Energy Accelerator Res Org, KEK, Tsukuba, Ibaraki 3050801, Japan
关键词
dose assessment; gamma radiation; lead; Monte Carlo; photoneutrons; radiation protection;
D O I
10.1016/j.nima.2004.10.028
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A design study of radiation shielding due to gas bremsstrahlung is performed for the First Optics Enclosure (FOE). To induce the radiation shower, a copper metal is placed at the entrance of the FOE, followed by a silicon crystal which is set in the middle of the FOE. A lead stop is placed near the lead back wall. To assess the radiation level outside of the FOE, the FOE is encompassed by a water phantom in which the energy deposition is estimated by a Monte Carlo simulation. The dose distributions behind the back, side walls and roof are obtained simultaneously. The average dose equivalent rates are estimated and the FOE radiation shielding wall is examined in detail. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:654 / 667
页数:14
相关论文
共 50 条
  • [21] THE CANADIAN LIGHT SOURCE.
    Quail, J. Wilson
    Delbaere, Louis T. J.
    Hallin, Emil L.
    Hawkins, Barry
    Cavell, Ronald G.
    Skopik, Dennis M.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 1999, 55 : 231 - 232
  • [22] Canadian Light Source magnets
    Dallin, L
    Lowe, D
    Swirsky, J
    PROCEEDINGS OF THE 2003 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 2003, : 2195 - 2197
  • [23] The shielding design of the metrology light source
    Ott, K
    PROCEEDINGS OF THE 2003 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 2003, : 776 - 778
  • [24] Considerations regarding shielding effectiveness and testing of electromagnetic protected enclosures used in communications security
    Bindar, Valerica
    Popescu, Mircea
    Vulpe, Alexandru
    2014 10TH INTERNATIONAL CONFERENCE ON COMMUNICATIONS (COMM), 2014,
  • [25] Electrical Shielding Effectiveness of Metallic Enclosures; Effect of Source Orientation and Aperture Dimension
    Basyigit, Ibrahim Bahadir
    Genc, Abdullah
    Helhel, Selcuk
    2017 PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM - SPRING (PIERS), 2017, : 795 - 799
  • [26] Study of the Shielding Effectiveness of Double Rectangular Enclosures with Apertures Excited by an Internal Source
    Hao, Jian-Hong
    Jiang, Lu-Hang
    Gong, Yan-Fei
    Fan, Jie-Qing
    PROGRESS IN ELECTROMAGNETICS RESEARCH M, 2016, 47 (47): : 67 - 76
  • [27] Radiation shielding study against gas bremsstrahlung for the BMIT POE3 at the Canadian light source
    Asai, Juhachi
    Wysokinski, Tomasz W.
    Chapman, Dean
    Mullin, Curtis
    RADIATION PHYSICS AND CHEMISTRY, 2011, 80 (06) : 716 - 722
  • [28] The optics beamline at the Swiss Light Source
    Flechsig, U.
    Jaggi, A.
    Spielmann, S.
    Padmore, H. A.
    MacDowell, A. A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 609 (2-3): : 281 - 285
  • [29] X-ray optics and diagnostics for the first experiments on the Linac Coherent Light Source
    Wootton, A
    Arthur, J
    Barbee, T
    Bionta, R
    London, R
    Park, HS
    Ryutov, D
    Spiller, E
    Tatchyn, R
    OPTICS FOR FOURTH-GENERATION X-RAY SOURCES, 2001, 4500 : 113 - 122
  • [30] Infrared beamlines at the Canadian Light Source
    May, Tim
    Appadoo, Dominique
    Ellis, Thomas
    Reininger, Ruben
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 579 - +