Comparison of different label-free imaging high-throughput biosensing systems for aptamer binding measurements using thrombin aptamers

被引:8
|
作者
Rath, Christin [1 ,2 ,3 ,5 ]
Burger, Juergen [1 ,5 ]
Norval, Leo [1 ]
Kraemer, Stefan Daniel [1 ,2 ]
Gensch, Nicole [4 ]
van der Kooi, Alexander [6 ]
Reinemann, Christine [7 ,10 ]
O'Sullivan, Ciara [8 ,9 ]
Svobodova, Marketa [8 ]
Roth, Guenter [1 ,2 ,3 ,5 ]
机构
[1] Univ Freiburg, Ctr Biol Syst Anal, Lab Microarray Copying, ZBSA, Habsburgerstr 49, D-79104 Freiburg, Germany
[2] Univ Freiburg, Fac Biol, Schanzlestr 1, D-79104 Freiburg, Germany
[3] Univ Freiburg, Ctr Biol Signaling Studies BIOSS, D-79104 Freiburg, Germany
[4] Univ Freiburg, Ctr Biol Signaling Studies BIOSS, Core Facil Signalling Factory, D-79104 Freiburg, Germany
[5] BioCopy GmbH, D-79110 Freiburg, Germany
[6] IBIS Technol Bv, NL-7521 PR Enschede, Netherlands
[7] Helmholtz Ctr Environm Res GmbH UFZ, Permoserstr 15, D-04318 Leipzig, Germany
[8] Univ Rovira & Virgili, Dept Engn Quim, E-43007 Tarragona, Spain
[9] Inst Catalana Recerca & Estudis Avancats, Barcelona 08010, Spain
[10] Aptamer Grp Ltd, Bio Ctr, Innovat Way, York YO10 5NY, N Yorkshire, England
关键词
Thrombin aptamer; Label-free; Reflecto-interferometry; BioLayer interferometry; Surface plasmon resonance; MicroScale thermophoresis; KINETICS; RECOGNITION; ADSORPTION; FIBRINOGEN; AFFINITY; PCR;
D O I
10.1016/j.ab.2019.05.012
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
To enable the analysis of several hundreds to thousands of interactions in parallel, high-throughput systems were developed. We used established thrombin aptamer assays to compare three such high-throughput imaging systems as well as analysis software and user influence. In addition to our own iRIf-system, we applied bscreen and IBIS-MX96. As non-imaging reference systems we used Octet-RED96, Biacore3000, and Monolith-NT.115. In this study we measured 1378 data points. Our results show that all systems are suitable for analyzing binding kinetics, but the kinetic constants as well as the ranking of the selected aptamers depend significantly on the applied system and user. We provide an insight into the signal generation principles, the systems and the results generated for thrombin aptamers. It should contribute to the awareness that binding constants cannot be determined as easily as other constants. Since many parameters like surface chemistry, biosensor type and buffer composition may change binding behavior, the experimenter should be aware that a system and assay dependent K-D is determined. Frequently, certain conditions that are best suited for a given biosensing system cannot be transferred to other systems. Therefore, we strongly recommend using at least two different systems in parallel to achieve meaningful results.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Label-Free High-Throughput Leukemia Detection by Holographic Microscopy
    Ugele, Matthias
    Weniger, Markus
    Stanzel, Manfred
    Bassler, Michael
    Krause, Stefan W.
    Friedrich, Oliver
    Hayden, Oliver
    Richter, Lukas
    ADVANCED SCIENCE, 2018, 5 (12)
  • [32] Label-free, high-throughput, electrical detection of cells in droplets
    Kemna, Evelien W. M.
    Segerink, Loes I.
    Wolbers, Floor
    Vermes, Istvan
    van den Berg, Albert
    ANALYST, 2013, 138 (16) : 4585 - 4592
  • [33] Aptamer-based label-free direct detection of thrombin using SERS
    Pagba, Cynthia V.
    Cho, Hansang
    Lane, Stephen
    Wachsmann-Hogiu, Sebastian
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2009, 237 : 491 - 491
  • [34] An Automated Pipeline for High-Throughput Label-Free Quantitative Proteomics
    Weisser, Hendrik
    Nahnsen, Sven
    Grossmann, Jonas
    Nilse, Lars
    Quandt, Andreas
    Brauer, Hendrik
    Sturm, Marc
    Kenar, Erhan
    Kohlbacher, Oliver
    Aebersold, Ruedi
    Malinstroemt, Lars
    JOURNAL OF PROTEOME RESEARCH, 2013, 12 (04) : 1628 - 1644
  • [35] Label-free high-throughput detection and content sensing of individual droplets in microfluidic systems
    Yesiloz, Gurkan
    Boybay, Muhammed Said
    Ren, Carolyn L.
    LAB ON A CHIP, 2015, 15 (20) : 4008 - 4019
  • [36] High-Throughput, Label-Free and Slide-Free Histological Imaging by Computational Microscopy and Unsupervised Learning
    Zhang, Yan
    Kang, Lei
    Wong, Ivy H. M.
    Dai, Weixing
    Li, Xiufeng
    Chan, Ronald C. K.
    Hsin, Michael K. Y.
    Wong, Terence T. W.
    ADVANCED SCIENCE, 2022, 9 (02)
  • [37] Label-free and high-throughput biosensing of multiple tumor markers on a single light-addressable photoelectrochemical sensor
    Wang, Juan
    Long, Juan
    Liu, Zhihong
    Wu, Wangze
    Hu, Chengguo
    BIOSENSORS & BIOELECTRONICS, 2017, 91 : 53 - 59
  • [38] High-throughput sperm assay using label-free microscopy: morphometric comparison between different sperm structures of boar and stallion spermatozoa
    Rubessa, Marcello
    Feugang, Jean M.
    Kandel, Mikhail E.
    Schreiber, Sierra
    Hessee, Jade
    Salerno, Francesca
    Meyers, Sascha
    Chu, Iwei
    Popescu, Gabriel
    Wheeler, Matthew B.
    ANIMAL REPRODUCTION SCIENCE, 2020, 219
  • [39] Titrationanalysis: A Tool for High-throughput Analysis of Binding Kinetics Data for Multiple Label-Free Platforms
    Li, Kan
    Horn, Gillian Q.
    Alam, S. Munir
    Tomaras, Georgia D.
    Dennison, S. Moses
    BIOPHYSICAL JOURNAL, 2021, 120 (03) : 265A - 266A
  • [40] Label-free high-throughput photoacoustic imaging of circulating melanoma tumor cells in patients in vivo
    Hai, P.
    Shmuylovich, L.
    Qu, Y.
    Cornelius, L. A.
    Wang, L.
    JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2018, 138 (05) : S204 - S204