Dynamic Characteristics Analysis of Steam Generator Tube of Nuclear Power Plant by Finite Elements

被引:0
|
作者
Jiang, Shuang [1 ]
Cai, Jun [1 ]
Zhang, J. W. [1 ]
Sun, Q. Z. [1 ]
Guo, Xin [1 ]
Wang, Y. D. [2 ]
机构
[1] North China Elect Power Univ, Sch Nucl Sci & Engn, Beijing, Peoples R China
[2] Beijing Univ Sci & Technol, State Key Lab Met Mat, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
steam generator; tube; ANSYS; vibration;
D O I
10.4028/www.scientific.net/AMM.577.149
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
In nuclear power plants, the steam generator heat transfer tube is the weakest part of the primary circuit pressure boundary. Flow induced vibration is one of the main reasons for the failure of the heat transfer tube. In this paper, an ANSYS finite element software is used to carry out the modal analysis of the heat transfer tube, and to simulate the dynamic response of the heat transfer tube in the harmonic load based on the modal analysis.
引用
收藏
页码:149 / +
页数:2
相关论文
共 50 条
  • [11] Dynamic Characteristics of the Steam Generator of the 200 MW Unit of the Beloyarskaya Nuclear Power Plant as an Object of Control of Temperature of Superheated Steam.
    Komarov, A.N.
    Artemov, A.S.
    Linev, V.I.
    Bronnikov, V.K.
    Gorbunov, A.I.
    Teploenergetika, 1973, (02): : 5 - 9
  • [12] Prediction of Defect Size of Steam Generator Tube in Nuclear Power Plant Using Neural Network
    Han, Ki-Won
    Jo, Nam-Hoon
    Lee, Hyang-Beom
    JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2007, 27 (05) : 383 - 392
  • [13] Development of Automated Tube Deposit Measurement System For Steam Generator Tubing of Nuclear Power Plant
    Kim, Min-Kyoung
    Jung, Nam-Du
    Yim, Xhang-Jae
    Park, Young-Woo
    ELECTROMAGNETIC NONDESTRUCTIVE EVALUATION (XVII), 2014, 39 : 173 - 182
  • [14] A Study on Quantitative Flaw Evaluation of Nuclear Power Plant Steam Generator Tube by Ultrasonic Testing
    Yoon, Byung-Sik
    Kim, Yong-Sik
    Lee, Hee-Jong
    Lee, Yong-Ho
    JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2006, 26 (01) : 12 - 17
  • [15] Failure analysis on unexpected fracture of the hydraulic expansion mandrel for tube to tubesheet expanding in the steam generator of nuclear power plant
    He, Guang-Qing
    Yang, Xiao-Lei
    Gong, Yi
    Lu, Dong-Qing
    Deng, Jian-Guo
    Gu, Jia-Lei
    Wu, Qiong
    Yang, Zhen-Guo
    ENGINEERING FAILURE ANALYSIS, 2023, 146
  • [16] Dynamic Performance of Synchronous Generator in Steam Power Plant
    Syahputra, Ramadoni
    Nugroho, Andi Wahyu
    Purwanto, Kunnu
    Mujaahid, Faaris
    INTERNATIONAL JOURNAL OF ADVANCED COMPUTER SCIENCE AND APPLICATIONS, 2019, 10 (12) : 389 - 396
  • [17] Study on Helium Leak Detection System for Heat Transfer Tube of Steam Generator in Nuclear Power Plant
    Yang J.
    Lei C.
    Ma X.
    Hedongli Gongcheng/Nuclear Power Engineering, 2021, 42 (06): : 219 - 224
  • [18] A Study on Bagging Neural Network for Predicting Defect Size of Steam Generator Tube in Nuclear Power Plant
    Kim, Kyung-Jin
    Jo, Nam-Hoon
    JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2010, 30 (04) : 302 - 310
  • [19] Distributed parameter modeling for the steam generator in the nuclear power plant
    Hui, Jiuwu
    Ling, Jun
    Dong, He
    Wang, Gaixia
    Yuan, Jingqi
    ANNALS OF NUCLEAR ENERGY, 2021, 152 (152)
  • [20] Steam Generator Replacement at the Obrigheim Nuclear Power Plant.
    Pickel, E.
    Schenk, H.
    Huemmeler, A.
    Atw. Atomwirtschaft, Atomtechnik, 1984, 29 (04): : 182 - 186