Comparison of two electromyographical endotracheal tube systems for intraoperative recurrent laryngeal nerve monitoring: reliability and side effects

被引:7
|
作者
Birkholz, Torsten [1 ]
Saalfrank-Schardt, Christina [1 ]
Irouschek, Andrea [1 ]
Klein, Peter [2 ]
Albrecht, Sven [1 ]
Schmidt, Joachim [1 ]
机构
[1] Univ Erlangen Nurnberg, Dept Anaesthesiol, D-91054 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Dept Surg, D-91054 Erlangen, Germany
关键词
Recurrent laryngeal nerve; Endotracheal tube; Electromyography; Endocrine surgical procedures; Intraoperative monitoring; Anaesthesiology; THYROID-SURGERY; TRACHEAL INTUBATION; QUALITY;
D O I
10.1007/s00423-011-0819-2
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background Recurrent laryngeal nerve (RLN) monitoring systems should be reliable and safe. Monitoring via electromyographical systems on an endotracheal tube (ETT) is widely spread. The MagStim (TM) system consists of an adhesive electrode to be fixed on an endotracheal tube. The Xomed (TM) endotracheal tube provides integrated electrodes. Reliability and side effects had never been compared. As both systems have very different morphological properties, we hypothesized that there might be differences in reliability and the incidence of side effects. Methods In a retrospective quality management analysis of 118 patients (MagStim (TM) electrode, 57 patients; Xomed (TM) ETT, 61 patients), we compared laryngeal side effects according to the Chilla score and detection rate of the RLN. Results Both systems had comparable detection rates of the RLN above 95%. Both electrode systems seemed to have similar reliability. Difficulties to detect the nerve were observed in seven patients (four with MagStim, three with Xomed). In the group with the Xomed (TM) ETT, significantly less mild laryngeal side effects were observed. Conclusion Both MagStim (TM) and Xomed (TM) ETT were reliable in detecting the RLN. The Xomed T ETT, however, might cause milder laryngeal side effects compared with the MagStim (TM) electrode.
引用
收藏
页码:1173 / 1179
页数:7
相关论文
共 50 条
  • [21] Comparison of a Handheld Device vs Endotracheal Tube-Based Neuromonitoring for Recurrent Laryngeal Nerve Stimulation
    Kong, Derek Kai
    Kong, Amanda M.
    Chai, Raymond L.
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2022, 166 (02) : 260 - 266
  • [22] Experience of monitoring the recurrent laryngeal nerve in thyroid surgery with endotracheal intubation
    Liang, Feng
    Liu, Guifeng
    Li, Huiying
    Li, Yunpengfei
    Li, Xuefeng
    2016 INTERNATIONAL CONFERENCE ON MEDICINE SCIENCES AND BIOENGINEERING (ICMSB2016), 2017, 8
  • [23] Reliabilty of intraoperative recurrent laryngeal nerve monitoring in thyroid surgery
    Jonas, J
    ZENTRALBLATT FUR CHIRURGIE, 2002, 127 (05): : 404 - 408
  • [24] Intraoperative recurrent laryngeal nerve monitoring in unconventional thyroid surgery
    Carta, Filippo
    Marrosu, Valeria
    Pinto, Valeria
    Tatti, Melania
    Bontempi, Mauro
    Mariani, Cinzia
    Puxeddu, Roberto
    CLINICAL CASE REPORTS, 2022, 10 (07):
  • [25] Comparison of the effects of two humidifier systems on endotracheal tube resistance
    Indalecio Morán
    Belén Cabello
    Elizabeth Manero
    Jordi Mancebo
    Intensive Care Medicine, 2011, 37 : 1773 - 1779
  • [26] Comparison of the effects of two humidifier systems on endotracheal tube resistance
    Moran, Indalecio
    Cabello, Belen
    Manero, Elizabeth
    Mancebo, Jordi
    INTENSIVE CARE MEDICINE, 2011, 37 (11) : 1773 - 1779
  • [27] Intraoperative monitoring of the recurrent laryngeal nerve by vagal nerve stimulation in thyroid surgery
    Brigitte Farizon
    Marie Gavid
    Alexandre Karkas
    Jean-Marc Dumollard
    Michel Peoc’h
    Jean-Michel Prades
    European Archives of Oto-Rhino-Laryngology, 2017, 274 : 421 - 426
  • [28] Intraoperative monitoring of the recurrent laryngeal nerve by vagal nerve stimulation in thyroid surgery
    Farizon, Brigitte
    Gavid, Marie
    Karkas, Alexandre
    Dumollard, Jean-Marc
    Peoc'h, Michel
    Prades, Jean-Michel
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2017, 274 (01) : 421 - 426
  • [29] Comparison of different methods for intraoperative identification of the recurrent laryngeal nerve
    Gericke, M
    Müller, W
    CURRENT PROBLEMS IN OTOLARYNGOLOGY 21, 1998, 21 : 244 - 249
  • [30] Intraoperative Recurrent Laryngeal Nerve Monitoring in Thyroid Surgery: Is It Worth the Cost?
    Gremillion, Grayson
    Fatakia, Adil
    Dornelles, Adriana
    Amedee, Ronald G.
    OCHSNER JOURNAL, 2012, 12 (04): : 363 - 366