Comparison of two electromyographical endotracheal tube systems for intraoperative recurrent laryngeal nerve monitoring: reliability and side effects

被引:7
|
作者
Birkholz, Torsten [1 ]
Saalfrank-Schardt, Christina [1 ]
Irouschek, Andrea [1 ]
Klein, Peter [2 ]
Albrecht, Sven [1 ]
Schmidt, Joachim [1 ]
机构
[1] Univ Erlangen Nurnberg, Dept Anaesthesiol, D-91054 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Dept Surg, D-91054 Erlangen, Germany
关键词
Recurrent laryngeal nerve; Endotracheal tube; Electromyography; Endocrine surgical procedures; Intraoperative monitoring; Anaesthesiology; THYROID-SURGERY; TRACHEAL INTUBATION; QUALITY;
D O I
10.1007/s00423-011-0819-2
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background Recurrent laryngeal nerve (RLN) monitoring systems should be reliable and safe. Monitoring via electromyographical systems on an endotracheal tube (ETT) is widely spread. The MagStim (TM) system consists of an adhesive electrode to be fixed on an endotracheal tube. The Xomed (TM) endotracheal tube provides integrated electrodes. Reliability and side effects had never been compared. As both systems have very different morphological properties, we hypothesized that there might be differences in reliability and the incidence of side effects. Methods In a retrospective quality management analysis of 118 patients (MagStim (TM) electrode, 57 patients; Xomed (TM) ETT, 61 patients), we compared laryngeal side effects according to the Chilla score and detection rate of the RLN. Results Both systems had comparable detection rates of the RLN above 95%. Both electrode systems seemed to have similar reliability. Difficulties to detect the nerve were observed in seven patients (four with MagStim, three with Xomed). In the group with the Xomed (TM) ETT, significantly less mild laryngeal side effects were observed. Conclusion Both MagStim (TM) and Xomed (TM) ETT were reliable in detecting the RLN. The Xomed T ETT, however, might cause milder laryngeal side effects compared with the MagStim (TM) electrode.
引用
收藏
页码:1173 / 1179
页数:7
相关论文
共 50 条
  • [1] Comparison of two electromyographical endotracheal tube systems for intraoperative recurrent laryngeal nerve monitoring: reliability and side effects
    Torsten Birkholz
    Christina Saalfrank-Schardt
    Andrea Irouschek
    Peter Klein
    Sven Albrecht
    Joachim Schmidt
    Langenbeck's Archives of Surgery, 2011, 396 : 1173 - 1179
  • [2] Middle fixation of electromyographic endotracheal tube for intraoperative recurrent laryngeal nerve monitoring
    Cherng, Chen-Hwan
    Huang, Yi-Hsuan
    Shih, Ming-Lang
    JOURNAL OF CLINICAL ANESTHESIA, 2014, 26 (03) : 252 - 253
  • [3] Intraoperative Monitoring of the Recurrent Laryngeal Nerve with Electromyography Endotracheal Tube in Anterior Cervical Discectomy and Fusion
    Niljianskul, Nattawut
    Phoominaonin, I-Sorn
    Jaiimsin, Alongkorn
    WORLD NEUROSURGERY-X, 2023, 17
  • [4] Use of the GlideScope for placement of a recurrent Laryngeal nerve monitoring endotracheal tube
    Berkow, Lauren
    Dackiw, Alan P. B.
    Tufano, Ralph P.
    JOURNAL OF CLINICAL ANESTHESIA, 2011, 23 (01) : 81 - 83
  • [5] A method of securing the Xomed endotracheal tube for accurate monitoring of the recurrent laryngeal nerve
    Nekhendzy, Vladimir
    Lopez, Jamie R.
    Damrose, Edward J.
    JOURNAL OF CLINICAL ANESTHESIA, 2012, 24 (03) : 259 - 260
  • [6] INTRAOPERATIVE RECURRENT LARYNGEAL NERVE MONITORING
    RICE, DH
    CONEWESSON, B
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1991, 105 (03) : 372 - 375
  • [7] Transtracheal monitoring of the recurrent laryngeal nerve. Prototype of a new endotracheal tube
    Lamade, W
    MeydingLamade, U
    Hund, E
    Senninger, N
    Herfarth, C
    CHIRURG, 1997, 68 (02): : 193 - 195
  • [8] Effects of Endotracheal Tube with Adhesive Superficial Laryngeal Electrodes for Intraoperative Nerve Monitoring on Laryngopharyngeal Complications during Thyroidectomy
    Moon, Jiae
    Kim, Jin Kyong
    Shin, Hye Jung
    Park, Jooeun
    Kim, Na Young
    Nam, Kee-Hyun
    BIOMEDICINES, 2023, 11 (09)
  • [9] Intraoperative monitoring of recurrent laryngeal nerve function
    Djohan, RS
    Rodriguez, HE
    Connolly, MM
    Childers, SJ
    Braverman, B
    Podbielski, FJ
    AMERICAN SURGEON, 2000, 66 (06) : 595 - 597
  • [10] Intraoperative electrophysiologic monitoring of the recurrent laryngeal nerve
    Eisele, DW
    LARYNGOSCOPE, 1996, 106 (04): : 443 - 449