The accuracy of commercially available upper and lower body bioelectrical impedance analyzers in men and women

被引:4
|
作者
Fahs, Christopher A. [1 ]
Boring, Johnathan [2 ]
LeVault, Lindsay [3 ]
Varner, William [3 ]
Beck, Maddison [3 ]
机构
[1] Logan Univ, Coll Hlth Sci, Chesterfield, MO 63017 USA
[2] Lindenwood Univ, Sch Hlth Sci, St Charles, MO USA
[3] Lindenwood Univ Belleville, Dept Exercise Sci, Belleville, IL USA
来源
关键词
body composition; body fat; lean body mass; air displacement plethysmography; AIR DISPLACEMENT PLETHYSMOGRAPHY; VALIDATION; VALIDITY;
D O I
10.1088/2057-1976/ab8269
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The purpose of this study was to determine if upper body (UB) and lower body (LB) bioelectrical impedance analysis (BIA) devices yield similar estimates of BF% as whole body (WB) BIA. Approach: Ninety-four men and women had their body composition evaluated using a Baseline 12-1190 Body Fat Scale (Fabrication Enterprises Inc.) as the LB BIA device, an Omron HBF-306C Handheld Body Fat Loss Monitor (Omron Healthcare, Inc.) as the UB BIA device, and a Seca Medical Body Composition Analyzer 514 (Seca North America) as the WB BIA device as well as via air displacement plethysmography (ADP; BodPod; Life Measurement Inc.). Main results: in women, the BF% was greater for WB BIA compared to UB BIA and LB BIA (28.9 5.0 versus 23.8 4.4 versus 20.4 5.9%; p < 0.001) with no differences between the WB BIA and ADP BF% (28.9 5.0 versus 28.3 7.5%; p = 0.982). In men, BF% was greater for WB BIA compared to UB BIA and LB BIA (19.1 6.7 versus 15.5 5.3 versus 14.9 4.0; p < 0.001) with no differences between the WB BIA and ADP BF% (19.1 6.7 versus 17.6 7.8; p = 0.394). Significance: Our findings suggest that the UB and LB BIA devices used in this study underestimate BF% compared to a WB BIA device and ADP in men and women.
引用
下载
收藏
页数:5
相关论文
共 50 条
  • [1] Accuracy of Consumer Grade Bioelectrical Impedance Analyzers to Assess Body Composition.
    Barnas, Jillian
    Micinski, Natalie
    Wheatley, Laura
    Laurson, Kelly
    Thomas, David
    Brown, Dale
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2014, 46 (05): : 619 - 619
  • [2] Accuracy of different types of bioelectrical impedance to estimate body fat in men
    Both, Diego Rodrigo
    Matheus, Silvana Correa
    Behenck, Mauri Schwank
    NUTRICION CLINICA Y DIETETICA HOSPITALARIA, 2015, 35 (02): : 8 - 15
  • [3] Accuracy of bioelectrical impedance for measurements of body composition in Hispanic American elderly women
    Bermudez, OI
    Valtuena, S
    Castaneda, C
    Waitekus, AB
    Sheahan, CA
    Tucker, KL
    Kehayias, JJ
    FASEB JOURNAL, 2001, 15 (05): : A1002 - A1002
  • [4] Reliability and Validity of Commercially Available Low-Cost Bioelectrical Impedance Analysis
    Vasold, Kerri L.
    Parks, Andrew C.
    Phelan, Deanna M. L.
    Pontifex, Matthew B.
    Pivarnik, James M.
    INTERNATIONAL JOURNAL OF SPORT NUTRITION AND EXERCISE METABOLISM, 2019, 29 (04) : 406 - 410
  • [5] Is Lower-Body Bioelectrical Impedance Comparable to Whole-Body Bioelectrical Impedance in High School Students?
    Bournas, Panagiota
    Wolowiec, Timothy
    Burland, Courtney
    Trefil, Sara
    Bournas, Vasilios
    Schurman, Regina
    JOURNAL OF GENERAL INTERNAL MEDICINE, 2012, 27 : 439 - 439
  • [6] Is Lower-Body Bioelectrical Impedance Comparable to Whole-Body Bioelectrical Impedance in High School Students?
    Bournas, Panagiota
    Wolowiec, Timothy
    Burland, Courtney
    Trefil, Sara
    Bournas, Vasilios
    Schurman, Regina
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2011, 43 (05): : 439 - 439
  • [7] Analysis of the influence of physical activity on body composition in women and men using bioelectrical impedance
    Sliwinski, Zbigniew
    Jedlikowski, Jakub
    Markowski, Kamil
    MEDICAL STUDIES-STUDIA MEDYCZNE, 2021, 37 (01) : 42 - 48
  • [8] PREDICTIVE ACCURACY OF BIOELECTRICAL-IMPEDANCE EQUATIONS FOR WOMEN
    JENKINS, KA
    HEYWARD, VH
    COOK, KL
    HICKS, VL
    QUATROCHI, JA
    WILSON, WL
    COLVILLE, BC
    AMERICAN JOURNAL OF HUMAN BIOLOGY, 1994, 6 (03) : 293 - 303
  • [9] Comparison of body fat using various bioelectrical impedance analyzers in university students
    Kutac, Petr
    Kopecky, Miroslav
    ACTA GYMNICA, 2015, 45 (04) : 177 - 186
  • [10] Accuracy of Segmental Bioelectrical Impedance Analysis for Predicting Body Composition in Pre- and Postmenopausal Women
    Tanaka, Noriko I.
    Hanawa, Satoshi
    Murakami, Haruka
    Cao, Zhen-Bo
    Tanimoto, Michiya
    Sanada, Kiyoshi
    Miyachi, Motohiko
    JOURNAL OF CLINICAL DENSITOMETRY, 2015, 18 (02) : 252 - 259