Plastic microfluidic chip for continuous-flow polymerase chain reaction: Simulations and experiments

被引:25
|
作者
Cao, QingQing [2 ]
Kim, Min-Cheol [1 ]
Klapperich, Catherine M. [1 ]
机构
[1] Boston Univ, Dept Biomed Engn, Boston, MA 02215 USA
[2] Boston Univ, Dept Mech Engn, Boston, MA 02215 USA
基金
美国国家卫生研究院;
关键词
Analytical biotechnology; Microfluidics; Micro total analysis; PCR; Thermofluidic modeling; REAL-TIME PCR; DNA AMPLIFICATION; MICROCHIP; DEVICE; EXTRACTION; LASER;
D O I
10.1002/biot.201000100
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A continuous flow polymerase chain reaction (CF-PCR) device comprises a single fluidic channel that is heated differentially to create spatial temperature variations such that a sample flowing through it experiences the thermal cycling required to induce amplification. This type of device can provide an effective means to detect the presence of a small amount of nucleic acid in very small sample volumes. CF-PCR is attractive for global health applications due to its less stringent requirements for temperature control than for other designs. For mass production of inexpensive CF-PCR devices, fabrication via thermoplastic molding will likely be necessary. Here we study the optimization of a PCR assay in a polymeric CF-PCR device. Three channel designs, with varying residence time ratios for the three PCR steps (denaturation, annealing, and extension), were modeled, built, and tested. A standardized assay was run on the three different chips, and the PCR yields were compared. The temperature gradient profiles of the three designs and the residence times of simulated DNA molecules flowing through each temperature zone were predicted using computational methods. PCR performance predicted by simulation corresponded to experimental results. The effects of DNA template size and cycle time on PCR yield were also studied. The experiments and simulations presented here guided the CF-PCR chip design and provide a model for predicting the performance of new CF-PCR designs prior to actual chip manufacture, resulting in faster turn around time for new device and assay design. Taken together, this framework of combined simulation and experimental development has greatly reduced assay development time for CF-PCR in our lab.
引用
下载
收藏
页码:177 / 184
页数:8
相关论文
共 50 条
  • [21] Kinetic characteristics of continuous flow polymerase chain reaction chip: A numerical investigation
    WANG ShiYing1 & WANG Wei2
    2 Institute of Microelectronics
    3 National Key Laboratory of Science and Technology on Micro/Nano Fabrication
    Science China Technological Sciences, 2010, (07) : 1967 - 1972
  • [22] Kinetic characteristics of continuous flow polymerase chain reaction chip: A numerical investigation
    WANG ShiYing WANG Wei School of Physics Peking University Beijing China Institute of Microelectronics Peking University Beijing China National Key Laboratory of Science and Technology on MicroNano Fabrication Beijing China
    Science China(Technological Sciences), 2010, 53 (07) : 1967 - 1972
  • [23] Kinetic characteristics of continuous flow polymerase chain reaction chip: A numerical investigation
    ShiYing Wang
    Wei Wang
    Science China Technological Sciences, 2010, 53 : 1967 - 1972
  • [24] Kinetic characteristics of continuous flow polymerase chain reaction chip: A numerical investigation
    Wang ShiYing
    Wang Wei
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2010, 53 (07) : 1967 - 1972
  • [25] Rapid detection of genetically modified organisms on a continuous-flow polymerase chain reaction microfluidics
    Li, Yuyuan
    Xing, Da
    Zhang, Chunsun
    ANALYTICAL BIOCHEMISTRY, 2009, 385 (01) : 42 - 49
  • [26] Cylindrical compact thermal-cycling device for continuous-flow polymerase chain reaction
    Park, N
    Kim, S
    Hahn, JH
    ANALYTICAL CHEMISTRY, 2003, 75 (21) : 6029 - 6033
  • [27] Experimental study of continuous-flow polymerase chain reaction microfluidics based on polytetrafluoroethylene capillary
    Zhang Chunsun
    Xu Jinliang
    Wang Jianqin
    Wang Hanping
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 (08) : 1197 - 1202
  • [28] Contamination free continuous flow microfluidic polymerase chain reaction for quantitative and clinical applications
    Dorfman, KD
    Chabert, M
    Codarbox, JH
    Rousseau, G
    de Cremoux, P
    Viovy, JL
    ANALYTICAL CHEMISTRY, 2005, 77 (11) : 3700 - 3704
  • [29] Computational thermal analysis of a continuous flow micro Polymerase Chain Reaction (PCR) chip
    Sugumar, D.
    Ashraf, Muhammad A.
    Kong, L. X.
    MICRO- AND NANOTECHNOLOGY: MATERIALS, PROCESSES, PACKAGING, AND SYSTEMS III, 2007, 6415
  • [30] Microfluidic chip for cyclical continuous-flow PCR - preliminary results of the technology
    Kubicki, Wojciech
    Sasowski, Maciej
    Wala, Arkadiusz
    2018 XV INTERNATIONAL SCIENTIFIC CONFERENCE ON OPTOELECTRONIC AND ELECTRONIC SENSORS (COE), 2018,