Comparison of half-dose and full-dose gadolinium MR contrast on the enhancement of bone and soft tissue tumors

被引:5
|
作者
Costelloe, Colleen M. [1 ]
Murphy, William A., Jr. [1 ]
Haygood, Tamara M. [1 ]
Kumar, Rajendra [1 ]
McEnery, Kevin W. [1 ]
Stafford, R. Jason [2 ]
Roy, Anjali
Bassett, Roland L., Jr. [3 ]
Harrell, Robyn K. [3 ]
Madewell, John E. [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Diagnost Radiol, Houston, TX 77030 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Biostat, Houston, TX 77030 USA
关键词
Half-dose gadolinium; Bone and soft tissue tumor; MRI; Reduced glomerular filtration rate (GFR); Nephrogenic systemic fibrosis; Renal failure; NEPHROGENIC SYSTEMIC FIBROSIS; GADOPENTETATE DIMEGLUMINE; FIELD-STRENGTH; DERMOPATHY; CHEMOTHERAPY; DIALYSIS;
D O I
10.1007/s00256-010-1028-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
To evaluate the effect of half-dose intravenous gadolinium contrast on the enhancement of bone and soft tissue tumors. This study is HIPAA compliant and informed consent was waived by the institutional review board. An institutional database search was performed over a 1-year period for patients with full- and half-dose MR examinations performed for musculoskeletal oncologic indications. Examination pairs that were identical with regard to field strength and presence or absence of fat saturation were included, resulting in 29 paired examinations. When multiple, the lesion that was best delineated and enhanced well on the first examination in the pair was chosen, yielding 17 bone and 12 soft tissue. Five musculoskeletal radiologists blinded to dosages were asked to assess for a difference in enhancement when comparing the lesion on both examinations and to rate the degree of difference on a three-point scale. They were also asked to identify the examination on which the lesion enhanced less (tallied as low dose). Results were analyzed with the exact binomial test. The readers perceived an enhancement difference in 41% (59/145) of studies (p = 0.03) and the majority were rated as "mild" (66%, 39/59). The readers did not accurately identify the low-dose examinations (54% correctly identified, 32/59, p = 0.60). Half-dose gadolinium enhancement of lesions could not be accurately distinguished from full-dose enhancement upon review of the same lesion imaged at both concentrations.
引用
收藏
页码:327 / 333
页数:7
相关论文
共 50 条
  • [31] Randomized, Double-Blind Comparison of Half-Dose Versus Full-Dose Edoxaban in 14,014 Patients With Atrial Fibrillation
    Steffel, Jan
    Ruff, Christian T.
    Yin, Ophelia
    Braunwald, Eugene
    Park, Jeong-Gun
    Murphy, Sabina A.
    Connolly, Stuart
    Antman, Elliott M.
    Giugliano, Robert P.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (09) : 1197 - 1207
  • [32] LANSOPRAZOLE FOR MAINTENANCE THERAPY OF PEPTIC-ULCER DISEASE - WEEKEND FULL-DOSE OR EVERYDAY HALF-DOSE ADMINISTRATION
    HOSHINO, E
    UMEDA, N
    SANO, J
    MIKI, K
    YAHAGI, N
    OKA, M
    KIMURA, M
    MIYASHITA, H
    JOURNAL OF CLINICAL GASTROENTEROLOGY, 1995, 20 : S72 - S74
  • [33] The Effect of Full-Dose Versus Half-Dose Ketamine for Induction During Rapid Sequence Intubation on Patient Outcomes
    Asberry, Cassandra
    Martini, Alaina
    CRITICAL CARE NURSING QUARTERLY, 2024, 47 (02) : 163 - 169
  • [34] Full-dose and half-dose Klean Prep produce clearer images with iliac duplex examination than Picolax
    Whiteley, MS
    Fox, AD
    Harris, RA
    Horrocks, M
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1998, 15 (03) : 261 - 266
  • [35] Half-dose abdominal CT with sinogram-affirmed iterative reconstruction technique in children — comparison with full-dose CT with filtered back projection
    Minwook Lee
    Myung-Joon Kim
    Kyung Hwa Han
    Mi-Jung Lee
    Pediatric Radiology, 2015, 45 : 188 - 193
  • [36] Half-dose abdominal CT with sinogram-affirmed iterative reconstruction technique in children - comparison with full-dose CT with filtered back projection
    Lee, Minwook
    Kim, Myung-Joon
    Han, Kyung Hwa
    Lee, Mi-Jung
    PEDIATRIC RADIOLOGY, 2015, 45 (02) : 188 - 193
  • [37] Dose Reduction in Abdominal Computed Tomography Intraindividual Comparison of Image Quality of Full-Dose Standard and Half-Dose Iterative Reconstructions With Dual-Source Computed Tomography
    May, Matthias S.
    Wuest, Wolfgang
    Brand, Michael
    Stahl, Christian
    Allmendinger, Thomas
    Schmidt, Bernhard
    Uder, Michael
    Lell, Michael M.
    INVESTIGATIVE RADIOLOGY, 2011, 46 (07) : 465 - 470
  • [38] Brain tumors:: Full- and half-dose contrast-enhanced MR imaging at 3.0 T compared with 1.5 T -: Initial experience
    Krautmacher, C
    Willinek, WA
    Tschampa, HJ
    Born, M
    Träber, F
    Gieseke, J
    Textor, HJ
    Schild, HH
    Kuhl, CK
    RADIOLOGY, 2005, 237 (03) : 1014 - 1019
  • [39] 3D PET/CT 82Rb PET myocardial blood flow quantification: comparison of half-dose and full-dose protocols
    Martin Lyngby Lassen
    Osamu Manabe
    Yuka Otaki
    Evann Eisenberg
    Phi T. Huynh
    Frances Wang
    Daniel S. Berman
    Piotr J. Slomka
    European Journal of Nuclear Medicine and Molecular Imaging, 2020, 47 : 3084 - 3093
  • [40] 3D PET/CT 82Rb PET myocardial blood flow quantification: comparison of half-dose and full-dose protocols
    Lassen, Martin Lyngby
    Manabe, Osamu
    Otaki, Yuka
    Eisenberg, Evann
    Huynh, Phi T.
    Wang, Frances
    Berman, Daniel S.
    Slomka, Piotr J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (13) : 3084 - 3093