X-ray-based attenuation correction for positron emission tomography/computed tomography scanners

被引:359
|
作者
Kinahan, PE
Hasegawa, BH
Beyer, T
机构
[1] Univ Washington, Med Ctr, Seattle, WA 98195 USA
[2] Univ Calif San Francisco, San Francisco, CA 94143 USA
[3] Univ Hosp, Essen, Germany
关键词
D O I
10.1053/snuc.2003.127307
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A synergy of positron emission tomography (PET)/computed tomography (CT) scanners is the use of the CT data for x-ray-based attenuation correction of the PET emission data. Current methods of measuring transmission use positron sources, gamma-ray sources, or x-ray sources. Each of the types of transmission scant involves different trade-offs of noise versus. bias, with positron transmission scans having the highest noise but lowest bias, whereas x-ray scant have negligible noise but the potential for increased quantitative errors. The use of x-ray-based attenuation correction, however, has other advantages, including a lack of bias introduced from post-injection transmission scanning, which is an important practical consideration for clinical scanners, as Well as reduced scan times. The sensitivity of x-ray-based attenuation correction to artifacts and quantitative errors depends on the method of translating the CT image from the effective x-ray energy of similar to70 keV to attenuation coefficients at the PET energy of 511 keV. these translation methods ate usually based on segmentation and/or scaling techniques. Errors in the PET emission image arise from positional mismatches caused by patient motion or respiration differences between the PET and CT scans; incorrect calculation of attenuation coefficients for CT contrast agents or metallic implants, or keeping the patient's arms in the field of view, which leads to truncation and/or beam-hardening (or x-ray scatter) artifacts. Proper interpretation of PET emission images corrected for attenuation by using the CT image relies on an understanding of the potential artifacts. 16 cases where an artifact or bias is suspected, careful inspection of all three available images (CT and PET emission with and without attenuation correction) is recommended. (C) 2003 Elsevier Inc. All rights reserved.
引用
收藏
页码:166 / 179
页数:14
相关论文
共 50 条
  • [1] Attenuation Correction Strategies for Positron Emission Tomography/Computed Tomography and 4-Dimensional Positron Emission Tomography/Computed Tomography
    Pan, Tinsu
    Zaidi, Habib
    [J]. PET CLINICS, 2013, 8 (01) : 37 - +
  • [2] Local Motion Correction and Influence of Attenuation Correction in Combined Positron Emission and X-Ray Computed Tomography
    Bundschuh, R. A.
    Martinez-Moeller, A.
    Essler, M.
    Delso, G.
    Nekolla, S. G.
    Schwaiger, M.
    Ziegler, S. I.
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 636 - 638
  • [3] Effect of oral contrast agents on computed tomography-based positron emission tomography attenuation correction in dual-modality positron emission tomography/computed tomography imaging
    Antoch, G
    Jentzen, W
    Freudenberg, LS
    Stattaus, J
    Mueller, SP
    Debatin, JF
    Bockisch, A
    [J]. INVESTIGATIVE RADIOLOGY, 2003, 38 (12) : 784 - 789
  • [4] X-ray emission computed tomography with attenuation correction for ICF research
    Chen, YW
    [J]. LASER INTERACTION AND RELATED PLASMA PHENOMENA, 1996, (369): : 538 - 543
  • [5] Computed tomography-based attenuation correction in neurological positron emission tomography: evaluation of the effect of the X-ray tube voltage on quantitative analysis
    Ay, MR
    Zaidi, H
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 2006, 27 (04) : 339 - 346
  • [6] ATTENUATION CORRECTION IN POSITRON EMISSION TOMOGRAPHY
    NATTERER, F
    HERZOG, H
    [J]. MATHEMATICAL METHODS IN THE APPLIED SCIENCES, 1992, 15 (05) : 321 - 330
  • [7] ATTENUATION CORRECTION IN POSITRON EMISSION TOMOGRAPHY
    GODDARD, J
    JACKSON, S
    KENNY, P
    BOLOMEY, L
    [J]. MEDICAL PHYSICS, 1981, 8 (04) : 553 - 553
  • [8] ATTENUATION CORRECTION IN CARDIAC POSITRON EMISSION TOMOGRAPHY AND SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY
    BACHARACH, SL
    BUVAT, I
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 1995, 2 (03) : 246 - 255
  • [9] Filtered attenuation correction in positron emission tomography
    Demirkaya, O
    Al Mazrou, RY
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (08): : 968 - 968
  • [10] Attenuation correction in hybrid positron emission tomography
    Turkington, TG
    [J]. SEMINARS IN NUCLEAR MEDICINE, 2000, 30 (04) : 255 - 267