GPU-based fast pencil beam algorithm for proton therapy

被引:18
|
作者
Fujimoto, Rintaro [1 ]
Kurihara, Tsuneya [2 ]
Nagamine, Yoshihiko [1 ]
机构
[1] Hitachi Ltd, Energy & Environm Syst Lab, Hitachi, Ibaraki 3191221, Japan
[2] Hitachi Ltd, Cent Res Lab, Kokubunji, Tokyo 1858601, Japan
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2011年 / 56卷 / 05期
关键词
D O I
10.1088/0031-9155/56/5/006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Performance of a treatment planning system is an essential factor in making sophisticated plans. The dose calculation is a major time-consuming process in planning operations. The standard algorithm for proton dose calculations is the pencil beam algorithm which produces relatively accurate results, but is time consuming. In order to shorten the computational time, we have developed a GPU (graphics processing unit)-based pencil beam algorithm. We have implemented this algorithm and calculated dose distributions in the case of a water phantom. The results were compared to those obtained by a traditional method with respect to the computational time and discrepancy between the two methods. The new algorithm shows 5-20 times faster performance using the NVIDIA GeForce GTX 480 card in comparison with the Intel Core-i7 920 processor. The maximum discrepancy of the dose distribution is within 0.2%. Our results show that GPUs are effective for proton dose calculations.
引用
收藏
页码:1319 / 1328
页数:10
相关论文
共 50 条
  • [31] A GPU-Based Approximate SVD Algorithm
    Foster, Blake
    Mahadevan, Sridhar
    Wang, Rui
    PARALLEL PROCESSING AND APPLIED MATHEMATICS, PT I, 2012, 7203 : 569 - 578
  • [32] A Fast GPU-Based Motion Estimation Algorithm for H.264/AVC
    Rodriguez-Sanchez, Rafael
    Luis Martinez, Jose
    Fernandez-Escribano, Gerardo
    Luis Sanchez, Jose
    Manuel Claver, Jose
    ADVANCES IN MULTIMEDIA MODELING, 2012, 7131 : 551 - +
  • [33] Ultra-fast scintillator-based dosimeter for pencil beam scanning proton FLASH therapy
    Kanouta, E.
    Johansen, J.
    Kertzscher, G.
    Sitarz, M.
    Sorensen, B.
    Poulsen, P.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S388 - S390
  • [34] Fast MCsquare-Based Independent Dose Verification Platform for Pencil Beam Scanning Proton Therapy
    Zhang, Y.
    Liu, C.
    Ho, M.
    Park, J.
    Hsi, W.
    Liang, X.
    Li, Z.
    Song, Y.
    Feng, H.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [35] A pencil beam algorithm for proton dose calculations
    Hong, L
    Goitein, M
    Bucciolini, M
    Comiskey, R
    Gottschalk, B
    Rosenthal, S
    Serago, C
    Urie, M
    PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (08): : 1305 - 1330
  • [36] Fast MCsquare-Based Independent Dose Verification Platform for Pencil Beam Scanning Proton Therapy
    Liu, Chunbo
    Ho, Meng Wei
    Park, Jiyeon
    Hsi, Wen Chien
    Liang, Xiaoying
    Li, Zuofeng
    Song, Yuntao
    Feng, Hansheng
    Zhang, Yawei
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2021, 20
  • [37] FAST GPU-BASED INTERPOLATION FOR SAR BACKPROJECTION
    Capozzoli, A.
    Curcio, C.
    Liseno, A.
    PROGRESS IN ELECTROMAGNETICS RESEARCH-PIER, 2012, 133 : 259 - 283
  • [38] GPU-Based Parallelization for Fast Circuit Optimization
    Liu, Yifang
    Hu, Jiang
    ACM TRANSACTIONS ON DESIGN AUTOMATION OF ELECTRONIC SYSTEMS, 2011, 16 (03)
  • [39] GPU-based fast image copy detection
    Xie, Hongtao
    Gao, Ke
    Zhang, Yongdong
    Li, Jintao
    Liu, Yizhi
    Jisuanji Fuzhu Sheji Yu Tuxingxue Xuebao/Journal of Computer-Aided Design and Computer Graphics, 2010, 22 (09): : 1483 - 1490
  • [40] GPU-based fast gamma index calculation
    Gu, Xuejun
    Jia, Xun
    Jiang, Steve B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (05): : 1431 - 1441