Coordinated Control Approaches for Low-Voltage Ride-Through Enhancement in Wind Turbines With Doubly Fed Induction Generators

被引:82
|
作者
Rahimi, Mohsen [1 ]
Parniani, Mostafa [1 ]
机构
[1] Sharif Univ Technol, Dept Elect Engn, Tehran 11155, Iran
关键词
Coordinated control; dc-link voltage; doubly fed induction generator (DFIG); low voltage ride through; wind turbine; STRATEGY;
D O I
10.1109/TEC.2010.2050485
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper deals with the coordinated control of rotor-and grid-side converters in wind turbines with doubly fed induction generators (DFIGs) to improve the low-voltage ride-through capability. The rotor-side converter control and additional equipment, called stator damping resistor, are used to limit the rotor inrush current and to reduce the oscillations and settling time of DFIG transient response during the voltage dip. Also, the grid-side converter is controlled to limit the dc-link overvoltage during the voltage drop. It is found that the dynamics of the grid-side converter and dc-link voltage exhibit nonminimum phase behavior, and thus there is an inherent limitation on the achievable dynamic response during the fault. Since the dc-link dynamics is nonlinear, the linear control scheme cannot properly limit the dc-link voltage under large voltage dips. Thus, a nonlinear control scheme applied to the grid-side converter is proposed, which stabilizes the internal dynamics and limits the dc-link voltage fluctuations during the fault. The proposed ride-through approaches limit the peak values of rotor current and dc-link voltage at the instants of occurring and clearing the fault. They also limit the oscillations of electromagnetic torque, and consequently, improve the DFIG voltage dip behavior.
引用
收藏
页码:873 / 883
页数:11
相关论文
共 50 条
  • [42] Fast Coordinated Control of DFIG Wind Turbine Generators for Low and High Voltage Ride-Through
    Wang, Yun
    Wu, Qiuwei
    Xu, Honghua
    Guo, Qinglai
    Sun, Hongbin
    [J]. ENERGIES, 2014, 7 (07): : 4140 - 4156
  • [43] Low-Voltage Ride-Through Capability for Wind Generators Based on Dynamic Voltage Restorers
    Ramirez, Dionisio
    Martinez, Sergio
    Platero, Carlos A.
    Blazquez, Francisco
    de Castro, Rosa M.
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2011, 26 (01) : 195 - 203
  • [44] Low-Voltage Ride-Through Remote Testing Method for Offshore Wind Turbines
    Jiang, Zimin
    Liu, Yutian
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (06) : 2905 - 2913
  • [45] A new method based on state-estimation technique to enhance low-voltage ride-through capability of doubly-fed induction generator wind turbines
    Shahriari, Sayyed Ali Akbar
    Mohammadi, Mohammad
    Raoofat, Mandi
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2018, 95 : 118 - 127
  • [46] New low voltage ride-through structure for doubly fed induction generator
    [J]. Jiang, S. (jsd1210@sohu.com), 1600, Science Press (35):
  • [47] Closure to Discussion on "A Genetic Algorithm-Based Low Voltage Ride-Through Control Strategy for Grid Connected Doubly Fed Induction Wind Generators"
    Vrionis, Theodoros
    Koutiva, Xanthi
    Vovos, Nicholas A.
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2015, 30 (01) : 549 - 549
  • [48] Improvement of low-voltage ride-through by coordinated pitch control and Crowbar control for DFIG wind turbine
    Ling, Yu
    Gao, Qiang
    Cai, Xu
    [J]. Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2013, 33 (04): : 18 - 23
  • [49] The Requirements and Technical Analysis of Low Voltage Ride Through for the Doubly-Fed Induction Wind Turbines
    Niu, Chen-guang
    Liu, Guan-qi
    [J]. PROCEEDINGS OF INTERNATIONAL CONFERENCE ON SMART GRID AND CLEAN ENERGY TECHNOLOGIES (ICSGCE 2011), 2011, 12
  • [50] IMC robust control for high-voltage ride-through of doubly fed induction wind generator
    Ma, Xiaoyang
    Yang, Honggeng
    [J]. IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2018, 13 (09) : 1265 - 1275