Integration of Surface EMG, US Imaging and 3D Kinematic: New Frontiers for Muscle Function Investigation

被引:1
|
作者
Bisi, Maria Cristina [1 ]
Botter, Alberto [2 ]
Stagni, Rita [1 ,3 ]
Vieira, Taian [2 ,4 ]
机构
[1] Univ Bologna, DEI, Bologna, Italy
[2] Politecn Torino, LISiN, Turin, Italy
[3] Univ Bologna, HST ICIR, Bologna, Italy
[4] Univ Fed Rio de Janeiro, EEFD, Rio De Janeiro, Brazil
关键词
HD EMG; US system; muscle function; SYSTEM; IMAGES;
D O I
10.1007/978-3-319-11128-5_89
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The integration of grids of electrodes, US imaging and 3D kinematic can allow investigating how muscle architectural changes influence surface EMGs: this innovative approach can provide novel spatio-temporal information regarding electromechanical function of muscle, relevant both for improving basic knowledge and for clinical applications. The aims of the present study were i) to verify whether movements of the US probe lead to artefacts in surface EMGs detected with a grid of electrodes transparent to US; ii) to analyse how much muscle architectural changes, induced by changes in joint positions, can influence the amplitude distribution of surface EMGs. A young healthy participant performed contractions of the right tibialis anterior (TA) at two different ankle positions: A) neutral and B) full plantarflexion. While provided with EMG visual feedback, the participant was asked to recruit a single motor unit: contractions lasted similar to 50 s. Surface EMGs, kinematic data and ultrasound images were acquired. The spatial distribution of the root mean square amplitude of motor unit action potentials was assessed from collected EMGs. Ankle angles were obtained from 3D kinematics. Muscle volume was obtained through the segmentation of US images reconstructed in 3D space: width and thickness variations between the two positions were measured. Movements of the US probe over the grid of electrodes did not result in artefacts in the surface EMGs. Results indicate a marked effect of TA architecture on the amplitude distribution of action potentials of a single TA motor unit. When moving the foot from plantarflexion to neutral position, TA width increased of 11.6%. Interestingly, a corresponding increase in the RMS spatial distribution was observed for the ankle neutral position. Presuming the same motor unit was recruited for both ankle positions, the changes in EMG amplitude reported here were predominantly due to TA architectural changes.
引用
收藏
页码:356 / +
页数:2
相关论文
共 50 条
  • [21] Arm function in LGMD studied with 3D movement kinematics and EMG
    Bergsma, A.
    Murgia, A.
    Cup, E.
    Meijer, K.
    De Groot, I. J. M.
    [J]. NEUROMUSCULAR DISORDERS, 2012, 22 (9-10) : 826 - 826
  • [22] Predicting 3D lip shapes using facial surface EMG
    Eskes, Merijn
    van Alphen, Maarten J. A.
    Balm, Alfons J. M.
    Smeele, Ludi E.
    Brandsma, Dieta
    van der Heijden, Ferdinand
    [J]. PLOS ONE, 2017, 12 (04):
  • [23] Puborectalis muscle function assessed by dynamic 3D ultrasound imaging and vaginal pressures
    Guaderrama, N
    Liu, JM
    Nager, CW
    Pretorius, DH
    Sheean, G
    Mittal, RK
    [J]. GASTROENTEROLOGY, 2005, 128 (04) : A266 - A266
  • [24] 3D imaging of tissue integration with porous biomaterials
    Guldberg, Robert E.
    Duvall, Craig L.
    Peister, Alexandra
    Oest, Megan E.
    Lin, Angela S. P.
    Palmer, Ashley W.
    Levenston, Marc E.
    [J]. BIOMATERIALS, 2008, 29 (28) : 3757 - 3761
  • [25] 3D reconstructions based on US imaging of the breast
    DelFavero, C
    Martegani, A
    Borghi, C
    Tufarulo, L
    Rossini, G
    Campi, R
    [J]. RADIOLOGY, 1997, 205 : 211 - 211
  • [26] Investigation and improvement of 3D rolling process for 3D surface parts
    Wang, Daming
    Li, Mingzhe
    Wang, You
    Cai, Zhongyi
    Liu, Hongwei
    [J]. INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2015, 78 (1-4): : 407 - 417
  • [27] Investigation and improvement of 3D rolling process for 3D surface parts
    Daming Wang
    Mingzhe Li
    You Wang
    Zhongyi Cai
    Hongwei Liu
    [J]. The International Journal of Advanced Manufacturing Technology, 2015, 78 : 407 - 417
  • [28] A new method for 3D integration of coronary anatomy and quantitative cardiac PET imaging
    Marinelli, M.
    Positano, V.
    Marcheschi, P.
    Todiere, G.
    Esposito, N.
    L'Abbate, G. A.
    Marraccini, P.
    Nekolla, S. G.
    Neglia, D.
    [J]. EUROPEAN HEART JOURNAL, 2012, 33 : 191 - 191
  • [29] Investigation of the Intrinsic Correlations of Patient Shifts Tracked by 3D Optical Surface Imaging
    Song, Y.
    Zhu, H.
    Tang, X.
    Voros, L.
    Zhang, M.
    Mueller, B.
    Mychalczak, B.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E547 - E547
  • [30] NEW ALGORITHMS FOR 3D SURFACE DESCRIPTION FROM BINOCULAR STEREO USING INTEGRATION
    KUMAR, KS
    DESAI, UB
    [J]. JOURNAL OF THE FRANKLIN INSTITUTE-ENGINEERING AND APPLIED MATHEMATICS, 1994, 331B (05): : 531 - 554