3D Absorbed Dose Reconstructed in the Patient from EPID Images for IMRT and VMAT Treatments

被引:0
|
作者
Younan, Fouad [1 ,2 ,3 ]
Mazurier, Jocelyne [1 ]
Chatrie, Frederic [4 ,5 ,6 ]
Barbeiro, Ana Rita [4 ,5 ]
Berry, Isabelle [2 ,3 ,7 ]
Franck, Denis [1 ]
Franceries, Xavier [4 ,5 ]
机构
[1] Clin Pasteur, Serv Radiotherapie, Grp Oncorad Garonne, 1 Rue Petite Vitesse, F-31300 Toulouse, France
[2] INSERM, UMR 1214, TONIC Toulouse NeuroImaging Ctr, F-31059 Toulouse, France
[3] Univ Toulouse III Paul Sabatier, UMR 1214, F-31059 Toulouse, France
[4] INSERM, UMR 1037, CRCT, F-31000 Toulouse, France
[5] Univ Toulouse III Paul Sabatier, UMR 1037, CRCT, F-31000 Toulouse, France
[6] CNRS, LAAS, F-31000 Toulouse, France
[7] CHU Rangueil, Dept Nucl Med, 1 Ave Prof Jean Poulhes, F-31400 Toulouse, France
关键词
Epid; Back-projection algorithm; 3D absorbed dose Dose verification; In vivo dosimetry; DOSIMETRY;
D O I
10.1007/978-981-10-9023-3_112
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A back-projection method has been used in this study to reconstruct the 3D absorbed dose matrix in the patient from EPID images for IMRT and VMAT fields. Images were acquired with the Clinac 23iX aS-1000 imager (Varian) and a 6 MV beam. Then a calibration step was performed to transform the grey levels of the pixels into absorbed dose in water via a response function. Correction kernels were also used to correct for the scatter within the EPID. The dose was then back-projected into the patient for all EPID parallel planes for each gantry angle. Finally the total dose was obtained by summing the 3D dose associated for each gantry angulation. First, the 3D dose reconstruction algorithm was tested for 20 IMRT and VMAT prostate and head and neck treatments in a homogeneous cylindrical phantom. Then the algorithm was used for IMRT brain cancer plans on 20 real patients. The EPID reconstructed 3D dose distributions were then compared to the planned dose from TPS (Treatment Planning System, Eclipse Varian) with a 3D global gamma index of 3% and 3 mm criteria. The percentage of points of which the gamma index was larger than unity was greater than 97% for all IMRT treatments both in the phantom and in the patients and over 96% for all VMAT treatments checked in the cylindrical phantom. Our 3D reconstruction algorithm, validated for homogeneous medium, can be used to verify the dose distribution for IMRT and VMAT fields using in vivo EPID images.
引用
收藏
页码:605 / 609
页数:5
相关论文
共 50 条
  • [41] Identification of 3D Surface Reconstructed Facial Images and Implications for Patient Privacy and Security
    Chen, J. J.
    Siddiqui, K. M.
    Juluru, K.
    Kim, W.
    Safdar, N.
    Siegel, E. L.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05)
  • [42] 3D Dose Reconstruction of Volumetric Modulated Arc Therapy From Delivered EPID Dose Image
    Yoon, J.
    Jung, J.
    Kim, J.
    Yeo, I.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 221 - 221
  • [43] HOLOGRAPHY OF 3D SURFACE RECONSTRUCTED CT IMAGES
    FUJIOKA, M
    OHYAMA, N
    HONDA, T
    TSUJIUCHI, J
    SUZUKI, M
    HASHIMOTO, S
    IKEDA, S
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1988, 12 (01) : 175 - 178
  • [44] FROM 2D TO 3D DOSE EVALUATION FOR IN VIVO IMRT VERIFICATION
    Camargo, P.
    Rozendaal, R.
    Joep, S.
    Sonke, J. J.
    van Herk, M.
    Mijnheer, B.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S214 - S214
  • [45] A model-based 3D patient-specific pre-treatment QA method for VMAT using the EPID
    McCowan, P. M.
    Asuni, G.
    van Beek, T.
    van Uytven, E.
    Kujanpaa, K.
    McCurdy, B. M. C.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (04): : 1600 - 1612
  • [46] VMAT lung SBRT: 3D evaluation in pretreatment patient QA and in vivo dose verification
    Villaggi, E.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S744 - S744
  • [47] 3D EPID based dosimetry for pre-treatment verification of VMAT - methods and challenges
    Greer, P. B.
    [J]. 7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2013, 444
  • [48] Quality improvement of 3D models reconstructed from silhouettes of multiple images
    [J]. Phothong, Watchama (p_watchama@hotmail.com), 2018, Bellwether Publishing, Ltd. (15):
  • [49] Evaluation of the respiratory motion influence in the 3D dose distribution of IMRT breast radiation therapy treatments
    Lizar, J. C.
    Santos, L. F.
    Brandao, F. C.
    Volpato, K. C.
    Guimaraes, F. S.
    Pavoni, J. F.
    [J]. 9TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, 2017, 847
  • [50] EPID-guided 3D dose verification of lung SBRT
    Aristophanous, M.
    Rottmann, J.
    Court, L. E.
    Berbeco, R. I.
    [J]. MEDICAL PHYSICS, 2011, 38 (01) : 495 - 503