Determination of lanthanide and actinide elements by energy dispersive x-ray fluorescence spectrometry applying DLLME preconcentration and dried spot

被引:7
|
作者
Sa, Ivero P. [1 ,2 ]
Almeida, Ohana N. [1 ]
Lima, Daniel De C. [1 ,3 ]
da Silva, Erik G. P. [1 ,3 ]
Santos, Luana N. [1 ]
Luzardo, Francisco H. M. [1 ]
Velasco, Fermin G. [1 ]
Gonzalez, Mario H. [4 ]
Amorim, Fabio A. C. [1 ,3 ]
机构
[1] State Univ Santa Cruz UESC, Dept Exact & Technol Sci, Jorge Amado Highway Km 16, BR-45662900 Ilheus, BA, Brazil
[2] Univ Fed Sao Carlos, Dept Chem, Grp Appl Instrumental Anal, BR-13560270 Sao Carlos, SP, Brazil
[3] Univ Fed Bahia, Natl Inst Energy & Environm Sci & Technol, BR-40170115 Salvador, BA, Brazil
[4] Paulista State Univ UNESP, Dept Chem & Environm Sci, IBILICE, POB 136, BR-15054000 Sao Jose Do Rio Preto, SP, Brazil
关键词
X-ray fluorescence spectrometry; Actinides; Lanthanides; Liquid phase microextraction; Dried spot; Multivariate optimization; Water analysis; RARE-EARTH-ELEMENTS; PLASMA-MASS SPECTROMETRY; LIQUID-LIQUID MICROEXTRACTION; ORGANIC DROP MICROEXTRACTION; HEAVY-METAL IONS; ULTRATRACE DETERMINATION; ANALYTICAL-CHEMISTRY; MATRIX ELIMINATION; WATER SAMPLES; ICP-MS;
D O I
10.1016/j.sab.2021.106253
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
This work describes an analytical procedure to determination of trace amount of lanthanide and actinide chemistry elements (LAEs) in water samples by energy dispersive x-ray fluorescence spectrometry (EDXRF) with the prepare of the samples using simultaneous preconcentration procedure based on the dispersive liquid-liquid microextraction (DLLME). Critical study of the analytical procedure occurred the following way: ions of Eu, Er, Ho, Th, U and Yb presents in 5.0 mL of aqueous sample have been complexed with 2-(5-bromo-2-pyridylazo)-5(diethylamino)-phenol (Br-PADAP) in a mixture contained solvents (disperser and extractant). After centrifugation, 30 mu L of the sedimented organic phase has been removed and deposited on membrane disk and submitted to EDXRF analysis. The optimization step was performed by: i) screening factor with mixture design for the disperser solvent (acetone, acetonitrile and ethanol) and extractant solvent (carbon tetrachloride, trichlorethylene and 1,2-dichloroethane); ii) Box-Behnken design for the independents variables: pH, Br-PADAP concentration, volume of disperser solvent and volume of extractant solvent. The optimized conditions were: 500 mu L of disperser solvent (ethanol), 60 mu L extractant solvent (carbon tetrachloride and trichlorethylene, 1: 1 ratio), BrPADAP 1.8 x 10-5 mol L-1 and pH 8.0. In these conditions, the procedure allows the determination of Eu, Ho, Er, Yb, Th and U with quantification limits of 10.5; 8.6; 4.3; 7.0; 6.6 and 1.1 mu g L-1, respectively; preconcentration factor between 18 and 74, and precision (RSD%) below that 6%. Salting out effect, presence of other ions, and additions/recoveries of analytes in real samples was verified and the recovery values were between of 90 to 107%. Analytical method has been applied in waters samples and groundwater from uranium mining region.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Determination of the sample thicknesses by intensity ratio measurement by energy dispersive x-ray fluorescence spectrometry
    Ekinci, N
    Baydas, E
    Sahin, Y
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 1999, 27 (03) : 181 - 189
  • [22] Solid phase extraction combined with energy dispersive X-ray fluorescence spectrometry for multielement determination
    Guimaraes, Leonardo B.
    Teixeira, Leonardo S. G.
    Amorim, Fabio A. C.
    Dias, Fabio de S.
    APPLIED SPECTROSCOPY REVIEWS, 2023, 58 (08) : 545 - 561
  • [23] Determination of the coating thicknesses due to the scattered radiation in energy dispersive X-ray fluorescence spectrometry
    Ekinci, N
    Kurucu, Y
    Öz, E
    Sahin, Y
    RADIATION MEASUREMENTS, 2002, 35 (03) : 223 - 227
  • [24] Comparative study of energy dispersive X-ray fluorescence spectrometry, wavelength dispersive X-ray fluorescence spectrometry and inductively coupled plasma-atomic emission spectrometry
    Rahmani, A
    Benyaïch, F
    Bounakhla, M
    Bilal, E
    Moutte, J
    Gruffat, JJ
    Zahry, F
    JOURNAL DE PHYSIQUE IV, 2004, 118 : 447 - 455
  • [25] Determination of Major Elements in Superphosphate by X-Ray Fluorescence Spectrometry
    Rui Yu-kui
    Li He
    Shen Jian-bo
    Mang Fu-suo
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28 (11) : 2703 - 2705
  • [26] Determination of trace elements in gasoline by X-ray fluorescence spectrometry
    Wang, Qian
    Wang, Qun-Wei
    Zhang, Jian-Bo
    Wang, Song-Qing
    Wu, Bei-Lei
    Shiyou Xuebao, Shiyou Jiagong/Acta Petrolei Sinica (Petroleum Processing Section), 2008, 24 (03): : 360 - 364
  • [27] Determination of elements in stainless steel by X-ray fluorescence spectrometry
    Lu, Ping-Ping
    An, Shen-Ping
    Hedongli Gongcheng/Nuclear Power Engineering, 2014, 35 (03): : 167 - 169
  • [28] Analysis of Endometriosis Using Energy Dispersive X-ray Fluorescence Spectrometry
    Ekinci, N.
    Ingec, M.
    Dogan, B.
    Agbaba, M.
    Senemtasi, E.
    ASIAN JOURNAL OF CHEMISTRY, 2012, 24 (04) : 1567 - 1570
  • [29] Determination of elements in some lichens growing in Giresun and Ordu province (Turkey) using energy dispersive X-ray fluorescence spectrometry
    Aslan, A
    Budak, G
    Tirasoglu, E
    Karabulut, A
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2006, 97 (01): : 10 - 19
  • [30] Energy-dispersive vs wavelength-dispersive X-ray fluorescence spectrometry
    Brill, M
    METALL, 1996, 50 (7-8): : 504 - 511