A path dependent stress-strain model for concrete-filled-steel-tube column

被引:223
|
作者
Lai, M. H. [1 ]
Song, W. [1 ]
Ou, X. L. [1 ]
Chen, M. T. [2 ,3 ,4 ]
Wang, Q. [1 ]
Ho, J. C. M. [1 ]
机构
[1] Guangzhou Univ, Sch Civil Engn, Guangzhou, Peoples R China
[2] Shanghai Jiao Tong Univ, State Key Lab Ocean Engn, Shanghai 200240, Peoples R China
[3] Shanghai Jiao Tong Univ, Dept Civil Engn, Shanghai 200240, Peoples R China
[4] Univ Hong Kong, Dept Civil Engn, Pokfulam Rd, Hong Kong, Peoples R China
关键词
Concrete-filled-steel-tube column; Hoop strain equation; Interface bonding; Stress-strain model; Stress path dependence; EXPERIMENTAL BEHAVIOR; UNIAXIAL BEHAVIOR; CONFINED CONCRETE; CFST COLUMNS; STRENGTH; PERFORMANCE; DESIGN;
D O I
10.1016/j.engstruct.2020.110312
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
High-strength concrete (HSC) has higher strength-to-weight ratio and stiffness than normal-strength concrete (NSC), which can decrease the size and embodied carbon of columns in tall buildings. Because of the brittleness of HSC, the practical design strength limit of HSC is usually limited for providing minimum ductility. One feasible way to extend this limit would be to use concrete-filled-steel-tube (CFST) column, which has a better strength-ductility performance. There are two shortcomings in theoretical models predicting the stress-strain behaviour of CFST column: (1) Most of the models did not consider the imperfect steel-concrete interface bonding due to their different dilations under axial compression; (2) A stress-path independent confining stress-strain relationship was adopted, which ignored the progressive development of tensile splitting cracks in concrete leading to a more gradual building up of confining stress under passive confinement than active pressure. Herein, to better understand and simulate the behaviour of CFST column, a theoretical stress-strain model, which consists of the following four main components, has been developed: (1) Interaction between steel tube and concrete taken into account the de-bonding effect; (2) An accurate hoop strain equation; (3) A passively confined concrete model considering stress-path dependence; (4) A three-dimensional stress-strain model for steel tube. Comparing with the measured load-strain curves obtained by the authors and other researchers, the accuracy of the proposed model in predicting the axial behaviour of CFST columns has been verified.
引用
收藏
页数:19
相关论文
共 50 条
  • [31] Stress-strain analytical model for FRP-confined concrete circular column
    Wang, Zhen-Yu
    Wang, Dai-Yu
    Lu, Da-Gang
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2010, 42 (02): : 200 - 206
  • [32] Evaluation of Concrete Filled Steel Tube Column Confined with FRP
    Pachideh, Ghasem
    Gholhaki, Majid
    JOURNAL OF TESTING AND EVALUATION, 2020, 48 (06) : 4343 - 4354
  • [33] Direct design method for concrete filled steel tube column
    Fan, Ping
    Zuo, Xindai
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2009, 30 (SUPPL. 2): : 261 - 264
  • [34] Investigation of Stress-Strain-Time Relationships of Concrete Filled Steel Tube Columns
    Secer, Mutlu
    Kural, Mehmet Emin
    PAMUKKALE UNIVERSITY JOURNAL OF ENGINEERING SCIENCES-PAMUKKALE UNIVERSITESI MUHENDISLIK BILIMLERI DERGISI, 2010, 16 (01): : 11 - 19
  • [35] Uni-Axial Compression Test of Concrete-Filled-Steel-Tube Columns Confined by Tie Bars
    Lai, M. H.
    Ho, J. C. M.
    MODERN BUILDING MATERIALS, STRUCTURES AND TECHNIQUES, 2013, 57 : 662 - 669
  • [36] Stress-strain relation of core concrete of aixally-loaded steel tubular columns filled with steel-reinforced concrete
    Xiao, A-Lin
    He, Yi-Bin
    Guo, Jian
    Zhongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Central South University (Science and Technology), 2010, 41 (01): : 341 - 346
  • [37] Stress-strain modelling of circular concrete-filled FRP-steel composite tube columns under axial compression load
    Hamed, Asmaa Y.
    Hassanein, M. F.
    Hasan, Mohamed Abdel-Shakour
    STRUCTURES, 2024, 67
  • [38] Prefabricated connection for steel beam and concrete-filled steel tube column
    Ding, Chenting
    Pan, Xuebei
    Bai, Yu
    Shi, Gang
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 162
  • [39] Assessment of stress-strain model for UHPC confined by steel tube stub columns
    An Le Hoang
    Fehling, Ekkehard
    STRUCTURAL ENGINEERING AND MECHANICS, 2017, 63 (03) : 371 - 384
  • [40] Research on Steel Beam-column Joints of Concrete Filled Steel Tube
    Li Ming
    Liu Yong
    Sun Zhezhe
    Liu Yongfang
    Du Jingfeng
    PROGRESS IN STRUCTURE, PTS 1-4, 2012, 166-169 : 43 - +