A path dependent stress-strain model for concrete-filled-steel-tube column

被引:223
|
作者
Lai, M. H. [1 ]
Song, W. [1 ]
Ou, X. L. [1 ]
Chen, M. T. [2 ,3 ,4 ]
Wang, Q. [1 ]
Ho, J. C. M. [1 ]
机构
[1] Guangzhou Univ, Sch Civil Engn, Guangzhou, Peoples R China
[2] Shanghai Jiao Tong Univ, State Key Lab Ocean Engn, Shanghai 200240, Peoples R China
[3] Shanghai Jiao Tong Univ, Dept Civil Engn, Shanghai 200240, Peoples R China
[4] Univ Hong Kong, Dept Civil Engn, Pokfulam Rd, Hong Kong, Peoples R China
关键词
Concrete-filled-steel-tube column; Hoop strain equation; Interface bonding; Stress-strain model; Stress path dependence; EXPERIMENTAL BEHAVIOR; UNIAXIAL BEHAVIOR; CONFINED CONCRETE; CFST COLUMNS; STRENGTH; PERFORMANCE; DESIGN;
D O I
10.1016/j.engstruct.2020.110312
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
High-strength concrete (HSC) has higher strength-to-weight ratio and stiffness than normal-strength concrete (NSC), which can decrease the size and embodied carbon of columns in tall buildings. Because of the brittleness of HSC, the practical design strength limit of HSC is usually limited for providing minimum ductility. One feasible way to extend this limit would be to use concrete-filled-steel-tube (CFST) column, which has a better strength-ductility performance. There are two shortcomings in theoretical models predicting the stress-strain behaviour of CFST column: (1) Most of the models did not consider the imperfect steel-concrete interface bonding due to their different dilations under axial compression; (2) A stress-path independent confining stress-strain relationship was adopted, which ignored the progressive development of tensile splitting cracks in concrete leading to a more gradual building up of confining stress under passive confinement than active pressure. Herein, to better understand and simulate the behaviour of CFST column, a theoretical stress-strain model, which consists of the following four main components, has been developed: (1) Interaction between steel tube and concrete taken into account the de-bonding effect; (2) An accurate hoop strain equation; (3) A passively confined concrete model considering stress-path dependence; (4) A three-dimensional stress-strain model for steel tube. Comparing with the measured load-strain curves obtained by the authors and other researchers, the accuracy of the proposed model in predicting the axial behaviour of CFST columns has been verified.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] A theoretical axial stress-strain model for circular concrete-filled-steel-tube columns
    Lai, M. H.
    Ho, J. C. M.
    ENGINEERING STRUCTURES, 2016, 125 : 124 - 143
  • [2] On the Stress-Strain of Steel Tube Column Filled with Steel-Reinforced Concrete Subject to Compression-Flexure Loading
    Liu, Xia
    Li, Min
    FRONTIERS OF GREEN BUILDING, MATERIALS AND CIVIL ENGINEERING, PTS 1-8, 2011, 71-78 : 3855 - 3860
  • [3] Theoretical Axial and Lateral Stress-Strain Model for Steel Tube-Reinforced Concrete Column
    Huang, Yuan
    Zhang, Xiao-Li
    Lu, Hua-Sen
    Han, Bing
    JOURNAL OF STRUCTURAL ENGINEERING, 2024, 150 (10)
  • [4] The nonlinear stress-strain state of the concrete-filled steel tube structures
    Snigireva, V. A.
    Gorynin, G. L.
    MAGAZINE OF CIVIL ENGINEERING, 2018, 83 (07): : 73 - 82
  • [5] Stress-strain model of an FRP-confined concrete filled steel tube under axial compression
    Zhang, Yirui
    Wei, Yang
    Bai, Jiawen
    Zhang, Yongxing
    THIN-WALLED STRUCTURES, 2019, 142 : 149 - 159
  • [6] Confining stress path dependent stress-strain model for pre-tensioned steel-confined concrete
    Chin, Chee-Loong
    Ma, Chau-Khun
    Awang, Abdullah Zawawi
    Tan, Jia-Yang
    Ong, Chin-Boon
    Omar, Wahid
    ENGINEERING STRUCTURES, 2019, 201
  • [7] Axial and lateral stress-strain model for concrete-filled steel tubes
    Kwan, A. K. H.
    Dong, C. X.
    Ho, J. C. M.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2016, 122 : 421 - 433
  • [8] Model for stress-strain curves of concrete filled steel tube-seawater and sea sand concrete filled FRP tube composite columns under axial load
    Miao K.
    Wei Y.
    Zhu C.
    Ding M.
    Zheng K.
    Fuhe Cailiao Xuebao/Acta Materiae Compositae Sinica, 2022, 39 (11): : 5403 - 5414
  • [9] Full-scale experimental research on shear capacity of concrete-filled-steel-tube column connections
    Kang, Liping
    Lü, Xilin
    Tongji Daxue Xuebao/Journal of Tongji University, 2014, 42 (08): : 1153 - 1160
  • [10] A stress-path dependent stress-strain model for FRP-confined concrete
    Lai, M. H.
    Liang, Y. W.
    Wang, Q.
    Ren, F. M.
    Chen, M. T.
    Ho, J. C. M.
    ENGINEERING STRUCTURES, 2020, 203