Experimental study on start-up characteristics of loop heat pipes

被引:12
|
作者
Zhang, HX
Lin, GP [1 ]
Ding, T
Shao, XG
Sudakov, RG
Maidanik, YF
机构
[1] Beijing Univ Aeronaut & Astronaut, Sch Aeronaut Sci & Engn, Beijing 100083, Peoples R China
[2] Beijing Inst Spacecraft Syst Engn, Beijing 100086, Peoples R China
[3] Russian Acad Sci, Ural Branch, Inst Thermal Phys, Ekaterinburg 620219, Russia
来源
关键词
loop heat pipe; start-up; experiment;
D O I
10.1360/04ye0236
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper presents results of ground-experimental study on the start-up characteristics of a Loop Heat Pipe. The physical process of start-up is described, and the explanation that "Pressure Transfer" leads to the saturated temperature rise in compensation chamber during start-up is first discussed. Start-up behaviors as a function of various parameters including vapor/liquid distribution in the evaporator, adverse elevation, start-up heat load, sink temperature are described and explained. A peculiar start-up phenomenon composed of two start-up scenarios was first observed at adverse elevations and is described.
引用
收藏
页码:131 / 144
页数:14
相关论文
共 50 条
  • [21] EXPERIMENTAL STUDY ON START-UP CHARACTERISTICS OF FREE PISTON STIRLING GENERATOR
    Lin, Mingqiang
    Liu, Runbao
    Chi, Chunyun
    Jiao, Kexin
    Zhou, Yuhao
    Mou, Jian
    [J]. Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2023, 44 (12): : 130 - 135
  • [22] Experimental study of the performance characteristics and start-up process of a novel temperature-control heat pipe
    Yuan, Zhu-Lin
    Zhao, Xiao-Bao
    [J]. Reneng Dongli Gongcheng/Journal of Engineering for Thermal Energy and Power, 2002, 17 (03): : 231 - 234
  • [23] A review on start-up characteristics of the pulsating heat pipe
    Zhang, Dongwei
    He, Zhuantao
    Jiang, Erhui
    Shen, Chao
    Zhou, Junjie
    [J]. HEAT AND MASS TRANSFER, 2021, 57 (05) : 723 - 735
  • [24] A review on start-up characteristics of the pulsating heat pipe
    Dongwei Zhang
    Zhuantao He
    Erhui Jiang
    Chao Shen
    Junjie Zhou
    [J]. Heat and Mass Transfer, 2021, 57 : 723 - 735
  • [25] Experimental investigation on start-up of mechanically pumped cooling loop
    Liu Jie
    Lv Mou
    Zhang Shuang-xi
    Guo Kai-hua
    He Zhen-hui
    Li Ting-xuen
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (10) : 2595 - 2601
  • [26] Experimental investigation on the start-up performance of a novel flat loop heat pipe with dual evaporators
    He, Song
    Ma, Zhengyuan
    Deng, Weizhong
    Zhang, ZiKang
    Guo, Ziqi
    Liu, Wei
    Liu, Zhichun
    [J]. ENERGY REPORTS, 2022, 8 : 7500 - 7507
  • [27] Experimental study on the influence of initial state parameters on the start-up and heat transfer characteristics of separated heat pipe system
    Zhou, Xinyu
    Lv, Jun
    Cheng, Hongyan
    Fan, Guangming
    Liu, Jianhui
    [J]. ANNALS OF NUCLEAR ENERGY, 2024, 208
  • [28] A preliminary experimental study on start-up behavior in nitrated gravity heat pipe
    Meng, Qiang
    Wu, Yuting
    Xiong, Yaxuan
    Cui, Wujun
    Liu, Shanwei
    Ma, Chongfang
    Li, Deying
    [J]. Huagong Xuebao/CIESC Journal, 2014, 65 (08): : 2908 - 2913
  • [29] Dynamic thermal heat pipes analysis: Thermal impedance in start-up condition
    Felczak, M.
    de Mey, G.
    Wiecek, B.
    Chatzipanagiotou, P.
    Chatziathanasiou, V
    [J]. MICROELECTRONICS JOURNAL, 2019, 93
  • [30] Simulation and experimental study on dynamic characteristics of R290 split heat pump during start-up
    Du, Yanjun
    Lin, Jie
    Wu, Jianhua
    Wang, Che
    Zhao, Tian
    Wu, Yuting
    [J]. APPLIED THERMAL ENGINEERING, 2024, 236