Diffusion-weighted whole-body MR imaging with background body signal suppression:: a feasibility study at 3.0 Tesla

被引:101
|
作者
Muertz, Petra
Krautmacher, Carsten
Traeber, Frank
Gieseke, Juergen
Schild, Hans H.
Willinek, Winfried A.
机构
[1] Univ Bonn, Dept Radiol, D-53105 Bonn, Germany
[2] Philips Med Syst, NL-5680DA Best, Netherlands
[3] Univ Bonn, Radiol Klin, D-53105 Bonn, Germany
关键词
Diffusion magnetic resonance imaging; Whole body imaging; High field; 3; 0; Tesla;
D O I
10.1007/s00330-007-0717-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose was to provide a diffusion-weighted whole-body magnetic resonance (MR) imaging sequence with background body signal suppression (DWIBS) at 3.0 Tesla. A diffusion-weighted spin-echo echo-planar imaging sequence was combined with the following methods of fat suppression: short TI inversion recovery (STIR), spectral attenuated inversion recovery (SPAIR), and spectral presaturation by inversion recovery (SPIR). Optimized sequences were implemented on a 3.0- and a 1.5-Tesla system and evaluated in three healthy volunteers and six patients with various lesions in the neck, chest, and abdomen on the basis of reconstructed maximum intensity projection images. In one patient with metastases of malignant melanoma, DWIBS was compared with F-18-fluorodeoxyglucose positron emission tomography (FDG-PET). Good fat suppression for all regions and diagnostic image quality in all cases could be obtained at 3.0 Tesla with the STIR method. In comparison with 1.5 Tesla, DWIBS images at 3.0 Tesla were judged to provide a better lesion-to-bone tissue contrast. However, larger susceptibility-induced image distortions and signal intensity losses, stronger blurring artifacts, and more pronounced motion artifacts degraded the image quality at 3.0 Tesla. A good correlation was found between the metastases as depicted by DWIBS and those as visualized by FDG-PET. DWIBS is feasible at 3.0 Tesla with diagnostic image quality.
引用
收藏
页码:3031 / 3037
页数:7
相关论文
共 50 条
  • [41] Clinical Utility of Diffusion-weighted Whole-body Magnetic Resonance Imaging with Background Body Signal Suppression for Assessing and Monitoring IgG4-related Disease
    Oshita, Akira
    Kono, Yusuke
    Miyoshi, Toru
    Suzuki, Moeko
    Kazatani, Takuro
    Matsuoka, Hiroshi
    Kawakami, Hideo
    INTERNAL MEDICINE, 2020, 59 (07) : 951 - 955
  • [42] Whole-body diffusion-weighted MRI for staging lymphoma at 3.0T: comparative study with MR imaging at 1.5T
    Azzedine, Benaissa
    Kahina, Moussa-Bouharati
    Dimitri, Papathanassiou
    Christophe, Portefaix
    Alain, Delmer
    Claude, Marcus
    CLINICAL IMAGING, 2015, 39 (01) : 104 - 109
  • [43] Whole-body diffusion-weighted magnetic resonance imaging in oncology
    Jouvet, Jean-Christophe
    Thomson, Vivien
    Durupt, Francois
    Bakir, Melisa
    Berthezene, Yves
    PRESSE MEDICALE, 2010, 39 (05): : 548 - 552
  • [44] Metastatic meningioma: The role of whole-body diffusion-weighted imaging
    Cabada, Teresa
    Bermejo, Rebeca
    Bacaicoa, Carmen
    Martinez-Penuela, Ana
    ONCOLOGY LETTERS, 2011, 2 (05) : 931 - 933
  • [45] Signal characteristics of normal adult bone marrow in whole-body diffusion-weighted imaging
    Cui, Feng-Zhen
    Cui, Jian-Ling
    Wang, Shi-Lei
    Yu, Hong
    Sun, Ying-Cai
    Zhao, Na
    Cui, Sheng-Jie
    ACTA RADIOLOGICA, 2016, 57 (10) : 1230 - 1237
  • [46] Artifact-robust diffusion-weighted whole-body imaging with background suppression at 3 T using improved turbo spin-echo diffusion-weighted imaging
    Suzuki, Makoto
    Morita, Satoru
    Goto, Yasuhiro
    Tadenuma, Hitoshi
    Nishina, Yu
    Yoneyama, Masami
    Tanaka, Isao
    Sakai, Shuji
    BRITISH JOURNAL OF RADIOLOGY, 2019, 92 (1094):
  • [47] Whole-Body Diffusion-Weighted Imaging: The Added Value to Whole-Body MRI at Initial Diagnosis of Lymphoma
    Gu, Jing
    Chan, Tao
    Zhang, Jingbo
    Leung, Anskar Y. H.
    Kwong, Yok-Lam
    Khong, Pek-Lan
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (03) : W384 - W391
  • [48] Diffusion-weighted whole-body imaging with background suppression (DWIBS) is effective and economical for detection of metastasis or recurrence of lung cancer
    Usuda, Katsuo
    Iwai, Shun
    Yamagata, Aika
    Iijima, Yoshihito
    Motono, Nozomu
    Matoba, Munetaka
    Doai, Mariko
    Yamada, Sohsuke
    Ueda, Yoshimichi
    Hirata, Keiya
    Uramoto, Hidetaka
    THORACIC CANCER, 2021, 12 (05) : 676 - 684
  • [49] Radiomics model of diffusion-weighted whole-body imaging with background signal suppression (DWIBS) for predicting axillary lymph node status in breast cancer
    Haraguchi, Takafumi
    Kobayashi, Yasuyuki
    Hirahara, Daisuke
    Kobayashi, Tatsuaki
    Takaya, Eichi
    Nagai, Mariko Takishita
    Tomita, Hayato
    Okamoto, Jun
    Kanemaki, Yoshihide
    Tsugawa, Koichiro
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2023, 31 (03) : 627 - 640
  • [50] Detection of bone metastases through diffusion-weighted whole-body imaging with background body signal suppression (DWIBS) compared with PET/CT 18F-NaF.
    Barragan-Campos, Hector Manuel
    Le Faou, Anne Laurence
    Burgos-Jaramillo, Martin
    Lopez-Soto, Fernando
    Ley, Javier Altamirano
    De la Pena-Lopez, Roberto
    JOURNAL OF CLINICAL ONCOLOGY, 2019, 37 (15)