An experimental study on the operating performance of a novel reverse-cycle hot gas defrosting method for air source heat pumps

被引:104
|
作者
Hu Wenju [2 ]
Jiang Yiqiang [2 ]
Qu Minglu [1 ]
Ni Long [2 ]
Yao Yang [2 ]
Deng Shiming [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Kowloon, Hong Kong, Peoples R China
[2] Harbin Inst Technol, Inst Heat Pump & Air Conditioning Technol, Harbin 150090, Peoples R China
关键词
Air source heat pumps; Defrosting; Thermal energy storage (TES); Phase change material (PCM); Reverse-cycle hot gas;
D O I
10.1016/j.applthermaleng.2010.09.024
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper reports on an experimental study on the operating performance for a novel reverse-cycle hot gas defrosting method for air source heat pumps (ASHPs). Firstly, a description of both an experimental prototype ASHP unit where the novel reverse-cycle hot gas defrosting method may be realized, and its operating modes are presented. This is followed by reporting an experimental set up for testing the defrosting performance of the prototype ASHP unit using the novel thermal energy storage (TES) based reverse-cycle hot gas defrosting method. Finally, experimental results are presented and discussed. The experimental results suggested that the use of the novel reverse-cycle hot gas defrosting method for the experimental ASHP unit was able to help shorten the defrosting time by similar to 3 min or 38%, and minimize the risk of shutting down the ASHP unit due to low suction pressure through increasing the compressor's suction pressure by about 200 kPa, when compared to the use of the traditional standard reverse-cycle hot gas defrosting method. In addition, when the TES based reverse-cycle hot gas defrosting method was used, the mean indoor coil surface temperature during defrosting was about 25 K higher than that when the traditional standard reverse-cycle hot gas defrosting method was used. These results suggested that as compared to the use of the traditional standard reverse-cycle hot gas defrosting method, the use of the novel TES based defrosting method would enable a quicker space heating resumption, impacting less on indoor thermal environment due to defrosting. Hence, the novel TES based defrosting method was proven to be effective in reducing the current problems in ASHPs using standard reverse-cycle hot gas defrosting method, such as a longer defrosting time and a poor system reliability. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:363 / 369
页数:7
相关论文
共 50 条
  • [31] Experimental investigation on the multi-mode heat discharge process of a PCM heat exchanger during TES based reverse cycle defrosting using in cascade air source heat pumps
    Qu Minglu
    Tang Yongbo
    Zhang Tongyao
    Li Zhao
    Chen Jianbo
    APPLIED THERMAL ENGINEERING, 2019, 151 : 154 - 162
  • [32] An experimental study on the effects of downwards flowing of melted frost over a vertical multi-circuit outdoor coil in an air source heat pump on defrosting performance during reverse cycle defrosting
    Song, Mengjie
    Deng, Shiming
    Pan, Dongmei
    Mao, Ning
    APPLIED THERMAL ENGINEERING, 2014, 67 (1-2) : 258 - 265
  • [33] Termination control temperature study for an air source heat pump unit during its reverse cycle defrosting
    Song Mengjie
    Wang Xuanjie
    Liao Liyuan
    Deng Shiming
    8TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY (ICAE2016), 2017, 105 : 335 - 342
  • [34] A modeling study on the effects of downwords flowing of the melt frost on reverse cycle defrosting for an air source heat pump
    School of Environment and Architecture, University of Shanghai for Science and Technology, Shanghai
    200093, China
    Taiyangneng Xuebao, 7 (1678-1683):
  • [35] AN EXPERIMENTAL STUDY ON PERFORMANCE IMPROVEMENT FOR AN AIR SOURCE HEAT PUMP BY ALTERNATE DEFROSTING OF OUTDOOR HEAT EXCHANGER
    Jung, Hoon
    Hwang, Jungho
    Jeon, Changduk
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2014, 22 (03)
  • [36] Field test study of a novel defrosting control method for air-source heat pumps by applying tube encircled photoelectric sensors
    Ge, Yijing
    Sun, Yuying
    Wang, Wei
    Zhu, Jiahe
    Li, Lintao
    Liu, Jingdong
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 66 : 133 - 144
  • [37] Hot gas defrosting method for air-source transcritical CO2 heat pump systems
    Hu, Bin
    Yang, Dongfang
    Cao, Feng
    Xing, Ziwen
    Fei, Jiyou
    ENERGY AND BUILDINGS, 2015, 86 : 864 - 872
  • [38] EFFECT OF SHORT-TUBE ORIFICE SIZE ON THE PERFORMANCE OF AN AIR SOURCE HEAT-PUMP DURING THE REVERSE-CYCLE DEFROST
    ONEAL, DL
    PETERSON, K
    ANAND, NK
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1991, 14 (01): : 52 - 57
  • [39] Experimental study of solution defrosting characteristics of air source heat pump
    Jiang, Ping
    Zhang, Yu
    Fan, Hongxiu
    Jin, Qi
    Yu, Yanshun
    APPLIED THERMAL ENGINEERING, 2024, 236
  • [40] Defrosting method adopting dual hot gas bypass for an air-to-air heat pump
    Choi, Hwan-Jong
    Kim, Byung-Soon
    Kang, Donghoon
    Kim, Kyung Chun