Advanced Control Strategy of DFIG Wind Turbines for Power System Fault Ride Through

被引:273
|
作者
Yang, Lihui [1 ]
Xu, Zhao [2 ]
Ostergaard, Jacob [3 ]
Dong, Zhao Yang [4 ]
Wong, Kit Po [5 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Peoples R China
[2] Hong Kong Polytech Univ, Dept Elect Engn, Hong Kong, Hong Kong, Peoples R China
[3] Tech Univ Denmark, Ctr Elect Technol, Dept Elect Engn, DK-2800 Lyngby, Denmark
[4] Univ Newcastle, Ctr Intelligent Elect Networks, Newcastle, NSW 2300, Australia
[5] Univ Western Australia, Sch Elect Elect & Comp Engn, Perth, WA 6009, Australia
关键词
Doubly fed induction generator (DFIG); low voltage ride through; power system fault; wind turbine; FED INDUCTION GENERATOR; THROUGH STRATEGY;
D O I
10.1109/TPWRS.2011.2174387
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents an advanced control strategy for the rotor and grid side converters of the doubly fed induction generator (DFIG) based wind turbine (WT) to enhance the low-voltage ride-through (LVRT) capability according to the grid connection requirement. Within the new control strategy, the rotor side controller can convert the imbalanced power into the kinetic energy of the WT by increasing its rotor speed, when a low voltage due to a grid fault occurs at, e. g., the point of common coupling (PCC). The proposed grid side control scheme introduces a compensation term reflecting the instantaneous DC-link current of the rotor side converter in order to smooth the DC-link voltage fluctuations during the grid fault. A major difference from other methods is that the proposed control strategy can absorb the additional kinetic energy during the fault conditions, and significantly reduce the oscillations in the stator and rotor currents and the DC bus voltage. The effectiveness of the proposed control strategy has been demonstrated through various simulation cases. Compared with conventional crowbar protection, the proposed control method can not only improve the LVRT capability of the DFIG WT, but also help maintaining continuous active and reactive power control of the DFIG during the grid faults.
引用
收藏
页码:713 / 722
页数:10
相关论文
共 50 条
  • [31] Unbalanced Control Strategy for DFIG Used in WindUnbalanced Control Strategy for DFIG Used in Wind Turbines
    Huang, Changxi
    Yang, Shuying
    Chen, Liuwei
    [J]. ENERGY AND POWER TECHNOLOGY, PTS 1 AND 2, 2013, 805-806 : 430 - 435
  • [32] Line-Fault Ride-Through (LFRT) Capabilities of DFIG Wind Turbine Connected to the Power System
    Khattara, A.
    Bahri, M.
    Aboubou, A.
    Becherif, M.
    Ayad, M. Y.
    [J]. 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND TECHNOLOGY - ICBET 2013, 2013, 7 : 189 - 194
  • [33] Supercapacitor energy storage system for fault ride-through of a DFIG wind generation system
    Rahim, A. H. M. A.
    Nowicki, E. P.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2012, 59 : 96 - 102
  • [34] Second-order sliding mode control for DFIG-based wind turbines fault ride-through capability enhancement
    Benbouzid, Mohamed
    Beltran, Brice
    Amirat, Yassine
    Yao, Gang
    Han, Jingang
    Mangel, Herve
    [J]. ISA TRANSACTIONS, 2014, 53 (03) : 827 - 833
  • [35] Improved fault ride through capability of DFIG-wind turbines using customized dynamic voltage restorer
    Sitharthan, R.
    Sundarabalan, C. K.
    Devabalaji, K. R.
    Nataraj, Sathees Kumar
    Karthikeyan, M.
    [J]. SUSTAINABLE CITIES AND SOCIETY, 2018, 39 : 114 - 125
  • [36] An Improved Control Strategy for DFIG Wind Turbine to Ride-Through Voltage Dips
    Lazrak, Ahmed
    Abbou, Ahmed
    [J]. 2018 6TH INTERNATIONAL RENEWABLE AND SUSTAINABLE ENERGY CONFERENCE (IRSEC), 2018, : 451 - 456
  • [37] Improving the Fault Ride-through Capability of DFIG-Based Wind Turbines Using the Dynamic Impedance
    Liang, Yabo
    Cao, Yunzhu
    Li, Lei
    Sheng, Yaru
    Niu, Jian
    He, Jianan
    [J]. 2022 4TH INTERNATIONAL CONFERENCE ON SMART POWER & INTERNET ENERGY SYSTEMS, SPIES, 2022, : 1185 - 1189
  • [38] Fault Ride Through Certification of Wind Turbines based on a Power Hardware in the Loop Setup
    Helmedag, Alexander
    Isermann, Timo
    Monti, Antonello
    [J]. 2013 IEEE INTERNATIONAL WORKSHOP ON APPLIED MEASUREMENTS FOR POWER SYSTEMS (AMPS), 2013, : 150 - 155
  • [39] Low voltage ride through control of DFIG wind energy generation system
    College of Electric Power, South China University of Technology, Guangzhou 510640, China
    [J]. Taiyangneng Xuebao, 2009, 11 (1527-1534):
  • [40] High Voltage Ride-Through of DFIG-based Wind Turbines
    Feltes, C.
    Engelhardt, S.
    Kretschmann, J.
    Fortmann, J.
    Koch, F.
    Erlich, I.
    [J]. 2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 1477 - 1484