Determination of water self-diffusion coefficient in complex food products by low field 1H PFG-NMR:: comparison between the standard spin-echo sequence and the T1-weighted spin-echo sequence

被引:25
|
作者
Métais, A [1 ]
Mariette, F [1 ]
机构
[1] UR Technol Equipements Agroalimentaires, Cemagref, F-35044 Rennes, France
关键词
H-1; NMR; low-field NMR; self-diffusion; relaxation; food products;
D O I
10.1016/j.jmr.2003.09.001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In 1990, Van Den Enden et al. proposed a method for the determination of water droplet size distributions in emulsions using a pulsed-field-gradient nuclear magnetic resonance (PFG-NMR) T-1-weighted stimulated-echo technique. This paper describes both the T-1-weighted spin-echo sequence, an improved method based on this earlier work, and, the standard PFG spin-echo sequence. These two methods were compared for water self-diffusion coefficient measurement in the fatty protein concentrate sample used as a 'cheese model.' The transversal and longitudinal relaxation parameters T-1 and T-2 were determined according to the temperature and investigated for each sample; fat-free protein concentrate sample, pure anhydrous milk fat, and fatty protein concentrate sample. The water self-diffusion in fat-free protein concentrate samples followed a linear behavior. Consequently, the water self-diffusion coefficient could be easily characterized for fat-free protein concentrate samples. However, it seemed more complicated to obtain accurate water self-diffusion in fatty protein concentrate samples since the diffusion-attenuation data were fitted by a bi-exponential function. This paper demonstrates that the implementation of the T-1-weighted spin-echo sequence, using the different T-1 properties of water and fat phases, allows the accurate determination of water self-diffusion coefficient in a food product. To minimize the contribution of the H-1 nuclei in the fat phase on the NMR echo signal, the fat protons were selectively eliminated by an additional 180degrees pulse. This new method reduces the standard errors of diffusion data obtained with a basic spin-echo technique, by a factor of 10. The effectiveness of the use of the T-1-weighted spin-echo sequence to perform accurate water self-diffusion coefficients measurement in fatty products is thus demonstrated. (C) 2003 Elsevier Inc. All rights reserved.
引用
收藏
页码:265 / 275
页数:11
相关论文
共 50 条
  • [31] Determining Asphaltene Aggregation in Solution from Diffusion Coefficients As Determined by Pulsed-Field Gradient Spin-Echo 1H NMR
    Kawashima, Hiroyuki
    Takanohashi, Toshimasa
    Iino, Masashi
    Matsukawa, Shingo
    ENERGY & FUELS, 2008, 22 (06) : 3989 - 3993
  • [32] Anisotropic self-diffusion in thermotropic liquid crystals studied by 1H and 2H pulse-field-gradient spin-echo NMR -: art. no. 061701
    Dvinskikh, SV
    Furó, I
    Zimmermann, H
    Maliniak, A
    PHYSICAL REVIEW E, 2002, 65 (06): : 1 - 061701
  • [33] Dependence of the concentration of asphaltenes and resins in solvents solutions on diffusion coefficient measurements using pulse field gradient spin-echo (PGSE) 1H NMR.
    Kawashima, H
    Takanohashi, T
    Iino, M
    Matsukawa, S
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2004, 228 : U655 - U655
  • [34] Contrast-enhanced Magnetic Resonance Imaging of Pelvic Bone Metastases at 3.0 T: Comparison Between 3-dimensional T1-weighted CAIPIRINHA-VIBE Sequence and 2-dimensional T1-weighted Turbo Spin-Echo Sequence
    Yoon, Min A.
    Hong, Suk-Joo
    Lee, Kyu-Chong
    Lee, Chang Hee
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2019, 43 (01) : 46 - 50
  • [35] Determination of Li+ self-diffusion coefficients in an aqueous suspension of sulfonated polystyrene latex by pulsed-field-gradient, spin-echo NMR
    Roberts, JM
    Sierzputowska-Gracz, H
    Stejskal, EO
    Osteryoung, JG
    JOURNAL OF PHYSICAL CHEMISTRY B, 1998, 102 (40): : 7735 - 7739
  • [36] Application of T1-weighted BLADE sequence to abdominal magnetic resonance imaging of young children: a comparison with turbo spin echo sequence
    Choi, Kyu Sung
    Choi, Young Hun
    Cheon, Jung-Eun
    Kim, Woo Sun
    Kim, In One
    ACTA RADIOLOGICA, 2020, 61 (10) : 1406 - 1413
  • [37] A fast high-resolution multislice T1-weighted turbo spin-echo (TSE) sequence with a DRIVen equilibrium (DRIVE) pulse for native arthrographic contrast
    Woertler, K
    Rummeny, EJ
    Settles, M
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (06) : 1468 - 1470
  • [38] Detection of corticospinal tract compromise in amyotrophic lateral sclerosis with brain MR imaging: Relevance of the T1-weighted spin-echo magnetization transfer contrast sequence
    da Rocha, AJ
    Oliveira, ASB
    Fonseca, RB
    Maia, ACM
    Buainain, RP
    Lederman, HM
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2004, 25 (09) : 1509 - 1515
  • [39] The value of chemical fat saturation pulse added to spin-echo T1-weighted sequence in evaluating gadolinium-enhancing brain lesions in multiple sclerosis
    Sardanelli, F
    Iozzelli, A
    Maiuri, F
    Tindiglia, C
    Rosso, E
    RADIOLOGY, 2001, 221 : 134 - 134
  • [40] SELF-DIFFUSION COEFFICIENT OF WATER CONFINED IN MESOPOROUS MCM-41 MATERIALS DETERMINED BY H-1 NUCLEAR-MAGNETIC-RESONANCE SPIN-ECHO MEASUREMENTS
    HANSEN, EW
    SCHMIDT, R
    STOCKER, M
    AKPORIAYE, D
    MICROPOROUS MATERIALS, 1995, 5 (03): : 143 - 150