Determination of water self-diffusion coefficient in complex food products by low field 1H PFG-NMR:: comparison between the standard spin-echo sequence and the T1-weighted spin-echo sequence

被引:25
|
作者
Métais, A [1 ]
Mariette, F [1 ]
机构
[1] UR Technol Equipements Agroalimentaires, Cemagref, F-35044 Rennes, France
关键词
H-1; NMR; low-field NMR; self-diffusion; relaxation; food products;
D O I
10.1016/j.jmr.2003.09.001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In 1990, Van Den Enden et al. proposed a method for the determination of water droplet size distributions in emulsions using a pulsed-field-gradient nuclear magnetic resonance (PFG-NMR) T-1-weighted stimulated-echo technique. This paper describes both the T-1-weighted spin-echo sequence, an improved method based on this earlier work, and, the standard PFG spin-echo sequence. These two methods were compared for water self-diffusion coefficient measurement in the fatty protein concentrate sample used as a 'cheese model.' The transversal and longitudinal relaxation parameters T-1 and T-2 were determined according to the temperature and investigated for each sample; fat-free protein concentrate sample, pure anhydrous milk fat, and fatty protein concentrate sample. The water self-diffusion in fat-free protein concentrate samples followed a linear behavior. Consequently, the water self-diffusion coefficient could be easily characterized for fat-free protein concentrate samples. However, it seemed more complicated to obtain accurate water self-diffusion in fatty protein concentrate samples since the diffusion-attenuation data were fitted by a bi-exponential function. This paper demonstrates that the implementation of the T-1-weighted spin-echo sequence, using the different T-1 properties of water and fat phases, allows the accurate determination of water self-diffusion coefficient in a food product. To minimize the contribution of the H-1 nuclei in the fat phase on the NMR echo signal, the fat protons were selectively eliminated by an additional 180degrees pulse. This new method reduces the standard errors of diffusion data obtained with a basic spin-echo technique, by a factor of 10. The effectiveness of the use of the T-1-weighted spin-echo sequence to perform accurate water self-diffusion coefficients measurement in fatty products is thus demonstrated. (C) 2003 Elsevier Inc. All rights reserved.
引用
收藏
页码:265 / 275
页数:11
相关论文
共 50 条
  • [1] Measurement of self-diffusion coefficient of asphaltene in pyridine by pulsed field gradient spin-echo 1H NMR
    Norinaga, K
    Wargardalam, VJ
    Takasugi, S
    Iino, M
    Matsukawa, S
    ENERGY & FUELS, 2001, 15 (05) : 1317 - 1318
  • [2] Multi-shot echo-planar Flair imaging of brain tumors: comparison of spin-echo T1-weighted, fast spin-echo T2-weighted, and fast spin-echo Flair imaging
    Tomura, N
    Kato, K
    Takahashi, S
    Sashi, R
    Izumi, J
    Narita, K
    Watarai, J
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2002, 26 (02) : 65 - 72
  • [3] Comparison of a T1-weighted inversion-recovery-, gradient-echo- and spin-echo sequence for imaging of the brain at 3.0 Testa
    Stehling, C
    Niederstadt, T
    Krämer, S
    Kugel, H
    Schwindt, W
    Heindel, W
    Bachmann, R
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2005, 177 (04): : 536 - 542
  • [4] Importance of signal intensity on T1-weighted spin-echo sequence for the diagnosis of chronic cholesteatomatous otitis
    Moustin, Deborah
    Veillon, Francis
    Karch-Georges, Aurelie
    Riehm, Sophie
    Djennaoui, Idir
    Charpiot, Anne
    Venkatasamy, Aina
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2020, 277 (06) : 1601 - 1608
  • [5] Importance of signal intensity on T1-weighted spin-echo sequence for the diagnosis of chronic cholesteatomatous otitis
    Deborah Moustin
    Francis Veillon
    Aurelie Karch-Georges
    Sophie Riehm
    Idir Djennaoui
    Anne Charpiot
    Aina Venkatasamy
    European Archives of Oto-Rhino-Laryngology, 2020, 277 : 1601 - 1608
  • [6] Comparison of Spin-Echo and Gradient-Echo T1-Weighted and Spin-Echo T2-Weighted Images at 3T in Evaluating Term-Neonatal Myelination
    Tyan, A. E.
    McKinney, A. M.
    Hanson, T. J.
    Truwit, C. L.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (02) : 411 - 416
  • [7] Water self-diffusion within nematic dispersions of nanocomposites:: A multiscale analysis of 1H pulsed gradient spin-echo NMR measurements
    Porion, P
    Al Mukhtar, M
    Faugère, AM
    Pellenq, RJM
    Meyer, S
    Delville, A
    JOURNAL OF PHYSICAL CHEMISTRY B, 2003, 107 (17): : 4012 - 4023
  • [8] Self-diffusion behavior of solvents in polypeptide gel as studied by pulsed-gradient spin-echo 1H NMR spectroscopy
    Zhao, CH
    Matsukawa, S
    Kurosu, H
    Ando, I
    MACROMOLECULES, 1998, 31 (09) : 3139 - 3141
  • [9] A Spiral Spin-Echo MR Imaging Technique for Improved Flow Artifact Suppression in T1-Weighted Postcontrast Brain Imaging: A Comparison with Cartesian Turbo Spin-Echo
    Li, Z.
    Hu, H. H.
    Miller, J. H.
    Karis, J. P.
    Cornejo, P.
    Wang, D.
    Pipe, J. G.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (04) : 642 - 647
  • [10] Comparison of T1-weighted Spin-Echo and 3D T1-weighted multishot echo planar pulse sequences in imaging the brain at 1T
    Karantanas, AH
    Papanikolaou, N
    Vasiou, K
    Lavdas, E
    MAGNETIC RESONANCE IMAGING, 1999, 17 (05) : 663 - 668