Determination of trace elements in high-purity molybdenum by solid-phase extraction/ICP-MS

被引:1
|
作者
Hasegawa, S [1 ]
Yamaguchi, H [1 ]
Yamada, K [1 ]
Kobayashi, T [1 ]
机构
[1] Natl Inst Mat Sci, Tsukuba, Ibaraki 3050047, Japan
来源
关键词
inductively coupled plasma mass spectrometry; solid-phase extraction; bonded silica as a solid-phase sorbent; beryllium; aluminum; magnesium; chromium; manganese; iron; cobalt; nickel; copper; zinc; gallium; cadmium; indium; thallium; lead and bismuth; trace analysis; pure molybdenum;
D O I
10.2320/jinstmet.69.127
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
We attempted a simple pretreating method consisting of solid-phase extraction using bonded silica gel with benzenesulfonic acid (SCX) as the solid-phase sorbent to determine trace elements in pure molybdenum samples by means of inductively coupled plasma mass spectrometry (ICP-MS). Molybdenum was anionized by adding hydrogen peroxide solution to a sample decomposed with acid, and separated from cation trace impurities that had been kept in the chemically bonded silica gel of the ion-exchange type. The target elements retained in the solid phase were eluent with a small amount of dilute nitric acid. In this method, some trace elements, such as Be, Al, Mg, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, Cd, In, Tl, Ph and Bi were determined by ICP-MS using the eluate. The detection limit (3 sigma), as follows: Be : 0.028, Al : 2.64, Mg : 1.99, Cr : 0.20, Mn 0.13, Fe : 3.85, Co : 0.019, Ni : 0.48, Cu : 0.084, Zn : 0.25, Ga : 0.092, Cd : 0.014, In : 0.059, TI : 0.027, Pb : 0.044 and Bi 0.012 ng/g(ppb).
引用
收藏
页码:127 / 131
页数:5
相关论文
共 50 条
  • [1] Determination of trace elements in high-purity molybdenum by solid-phase extraction/ICP-MS
    Hasegawa, SI
    Yamaguchi, H
    Yamada, K
    Kobayashi, T
    [J]. MATERIALS TRANSACTIONS, 2004, 45 (03) : 925 - 929
  • [2] Determination of trace elements in high-purity aluminum by solid-phase extraction/ICP-MS
    Hasegawa, S
    Yamaguchi, H
    Itoh, S
    Ide, K
    Kobayashi, T
    [J]. BUNSEKI KAGAKU, 2003, 52 (07) : 533 - 537
  • [3] Determination of Trace Elements in High Purity Tungsten by Solid-Phase Extraction/ICP-MS
    Hasegawa, Shin-ichi
    [J]. MATERIALS TRANSACTIONS, 2008, 49 (09) : 2054 - 2057
  • [4] Determination of Trace Elements in High Purity Tungsten Using Solid-Phase Extraction/ICP-MS
    Hasegawa, Shin-ichi
    [J]. JOURNAL OF THE JAPAN INSTITUTE OF METALS, 2009, 73 (01): : 15 - 18
  • [5] Determination of Thorium and Uranium in High-purity Gadolinium Sulfate by ICP-MS after Solid-phase Extraction
    Takemura, Katsunori
    [J]. BUNSEKI KAGAKU, 2021, 70 (4-5) : 239 - 245
  • [6] Determination of trace elements in high purity iron by solid phase extraction using bonded silica/ICP-MS
    Hasegawa, S
    Ide, K
    Kobayashi, T
    Sato, K
    Igarashi, S
    Naito, K
    [J]. TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 2003, 89 (09): : 958 - 961
  • [7] Application of Iron High-selectivity Solid Phase Extraction Resin to Simultaneous Determination of Trace Elements in High-purity Iron by ICP-MS
    Tsukahara, Hidekazu
    Nakashima, Yoichi
    [J]. TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 2021, 107 (10): : 806 - 813
  • [8] ICP-MS determination of trace amounts of boron in high-purity quartz
    Karunasagar, D
    Dash, K
    Chandrasekaran, K
    Arunachalam, J
    [J]. ATOMIC SPECTROSCOPY, 2000, 21 (06) : 216 - 219
  • [9] DETERMINATION OF TRACE AMOUNTS OF BORON IN HIGH-PURITY GRAPHITE BY ICP-MS
    MIYATANI, T
    SUZUKI, H
    YOSHIMOTO, O
    [J]. BUNSEKI KAGAKU, 1994, 43 (06) : 495 - 498
  • [10] Determination of Trace Level Thorium and Uranium in High Purity Gadolinium Sulfate Using ICP-MS with Solid-Phase Chromatographic Extraction Resins
    Ito, S.
    Takaku, Y.
    Ikeda, M.
    Kishimoto, Y.
    [J]. LOW RADIOACTIVITY TECHNIQUES 2017 (LRT 2017), 2018, 1921