Novel Use of Glucagon in a Closed-Loop System for Prevention of Hypoglycemia in Type 1 Diabetes

被引:151
|
作者
Castle, Jessica R. [1 ]
Engle, Julia M. [2 ]
Youssef, Joseph E. L. [1 ]
Massoud, Ryan G. [2 ]
Yuen, Kevin C. J. [1 ]
Kagan, Ryland [2 ]
Ward, W. Kenneth [1 ,2 ]
机构
[1] Oregon Hlth & Sci Univ, Dept Med, Div Endocrinol, Portland, OR 97201 USA
[2] Legacy Hlth, Div Res, Portland, OR USA
基金
美国国家卫生研究院;
关键词
INSULIN DELIVERY; CHILDREN; FIBRILS; RESCUE; RATS;
D O I
10.2337/dc09-2254
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE - To minimize hypoglycemia in subjects with type 1 diabetes by automated glucagon delivery in a closed-loop insulin delivery system. RESEARCH DESIGN AND METHODS - Adult subjects with type 1 diabetes underwent one closed-loop study with insulin plus placebo and one study with insulin plus glucagon, given at times of impending hypoglycemia. Seven subjects received glucagon using high-gain parameters, and six subjects received glucagon in a more prolonged manner using low-gain parameters. Blood glucose levels were measured every 10 min and insulin and glucagon infusions were adjusted every 5 min. All subjects received a portion of their usual premeal insulin after meal announcement. RESULTS - Automated glucagon plus insulin delivery, compared with placebo plus insulin, significantly reduced time spent in the hypoglycemic range (15 +/- 6 vs. 40 +/- 10 min/day, P = 0.04). Compared with placebo, high-gain glucagon delivery reduced the frequency of hypoglycemic events (1.0 +/- 0.6 vs. 2.1 +/- 0.6 events/day, P = 0.01) and the need for carbohydrate treatment (1.4 +/- 0.8 vs. 4.0 +/- 1.4 treatments/day, P = 0.01). Glucagon given with low-gain parameters did not significantly reduce hypoglycemic event frequency (P = NS) but did reduce frequency of carbohydrate treatment (P = 0.05). CONCLUSIONS - During closed-loop treatment in subjects with type 1 diabetes, high-gain pulses of glucagon decreased the frequency of hypoglycemia. Larger and longer-term studies will be required to assess the effect of ongoing glucagon treatment on overall glycemic control.
引用
收藏
页码:1282 / 1287
页数:6
相关论文
共 50 条
  • [41] Closed-Loop Artificial Pancreas Therapy for Type 1 Diabetes
    Zhou, Keren
    Isaacs, Diana
    CURRENT CARDIOLOGY REPORTS, 2022, 24 (09) : 1159 - 1167
  • [42] Closed-loop for type 1 diabetes - an introduction and appraisal for the generalist
    Bally, Lia
    Thabit, Hood
    Hovorka, Roman
    BMC MEDICINE, 2017, 15
  • [43] Closed-loop in children with type 1 diabetes: Specific challenges
    Elleri, Daniela
    Allen, Janet M.
    Dunger, David B.
    Hovorka, Roman
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2011, 93 : S131 - S135
  • [44] Closed-loop blood glucose control for type 1 diabetes
    Furutani E.
    IEEJ Transactions on Electronics, Information and Systems, 2019, 139 (04) : 260 - 263
  • [45] SLEEP AND FEAR OF HYPOGLYCEMIA IN PARENTS OF YOUTH WITH TYPE 1 DIABETES FOLLOWING IMPLEMENTATION OF HYBRID CLOSED-LOOP TECHNOLOGY
    Karami, A.
    Pyle, L.
    Vigers, T.
    Jost, E.
    Towers, L.
    Wadwa, R. P.
    Cobry, E.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 : A108 - A108
  • [46] Diurnal Pattern of Insulin Action in Type 1 Diabetes Implications for a Closed-Loop System
    Hinshaw, Ling
    Dalla Man, Chiara
    Nandy, Debashis K.
    Saad, Ahmed
    Bharucha, Adil E.
    Levine, James A.
    Rizza, Robert A.
    Basu, Rita
    Carter, Rickey E.
    Cobelli, Claudio
    Kudva, Yogish C.
    Basu, Ananda
    DIABETES, 2013, 62 (07) : 2223 - 2229
  • [47] Safety of a Hybrid Closed-Loop Insulin Delivery System in Patients With Type 1 Diabetes
    Bergenstal, Richard M.
    Garg, Satish
    Weinzimer, Stuart A.
    Buckingham, Bruce A.
    Bode, Bruce W.
    Tamborlane, William V.
    Kaufman, Francine R.
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2016, 316 (13): : 1407 - 1408
  • [48] The Closed-Loop System Improved the Control of a Pregnant Patient with Type 1 Diabetes Mellitus
    Guzman Gomez, Guillermo E.
    Viggiano, Julian A.
    Silva-De las Salas, A.
    Martinez, Veline
    Urbano Bonilla, Maria A.
    CASE REPORTS IN ENDOCRINOLOGY, 2021, 2021
  • [49] The Effect of a Closed-Loop Insulin Delivery System on Glycemic Control in Type 1 Diabetes
    Koutsovasilis, Anastasios
    Sotiropoulos, Alexios
    Antoniou, Anastasia
    Kordinas, Vasilios
    Papadaki, Despina
    Peppas, Theodoros
    DIABETES, 2019, 68
  • [50] Impact of an Advanced Hybrid Closed-Loop System on Glycemic Control Throughout the Menstrual Cycle in Women with Type 1 Diabetes Prone to Hypoglycemia
    Mesa, Alex
    Sola, Clara
    Vinagre, Irene
    Roca, Daria
    Granados, Montse
    Pueyo, Irene
    Cabre, Carla
    Conget, Ignacio
    Gimenez, Marga
    DIABETES TECHNOLOGY & THERAPEUTICS, 2024, 26 (09) : 667 - 672