Comparison of cuffed tunneled hemodialysis catheter survival

被引:7
|
作者
Rocklin, MA [1 ]
Dwight, CA [1 ]
Callen, LJ [1 ]
Bispham, BZ [1 ]
Spiegel, DM [1 ]
机构
[1] Univ Colorado, Hlth Sci Ctr, Dept Internal Med, Div Renal Dis & Hypertens, Denver, CO 80262 USA
关键词
hemodialysis (HD) access; central venous catheters; catheter infection;
D O I
暂无
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Despite efforts to have hemodialysis patients begin renal replacement therapy with a mature arteriovenous shunt, many patients begin dialysis with a cuffed tunneled catheter as their access. An increasing number of differently designed tunneled hemodialysis catheters have become available in the last decade. The primary aim of this study is to compare catheter survival for Hickman (Bard, Salt Lake City, UT) and Opti-flow (Bard) catheters. The 16-month experience with 182 catheters, totaling 13,861 catheter-days, is reported. The probability of Hickman catheter failure at 30, 60, and 90 days was 29%, 49%, and 67%. The probability of Opti-flow catheter failure was significantly less at 10%, 24%, and 38% for the same times, respectively (P < 0.05 for all time points). The difference in catheter failure rates was caused by a greater malfunction rate of Hickman catheters; the two catheters had similar infection rates. We conclude that survival of Opti-flow catheters was significantly better than that of Hickman catheters from 30 to 90 days, which is a clinically relevant period when patients are waiting for maturation of a permanent access or replacement of a failed access. Since the conclusion of our study, we documented 10 episodes of Opti-flow catheter malfunction within 4 months secondary to hairline fracture of the arterial hub. The Opti-flow catheter was recalled and is now available with retooled hubs. (C) 2001 by the National Kidney Foundation, Inc.
引用
收藏
页码:557 / 563
页数:7
相关论文
共 50 条
  • [21] Bacteremia associated with tunneled, cuffed hemodialysis catheters
    Saad, TF
    AMERICAN JOURNAL OF KIDNEY DISEASES, 1999, 34 (06) : 1114 - 1124
  • [22] Catheter failure and mortality in hemodialysis patients with the tunneled-cuffed catheter tip positioned in the inferior vena cava
    Cheng, Lu
    Ren, Qian
    Yu, Gang
    Gou, Shenju
    Cui, Tianlei
    Fu, Ping
    CHINESE MEDICAL JOURNAL, 2022, 135 (19) : 2369 - 2371
  • [23] Tunneled cuffed hemodialysis catheter (TCC) bacteremia: Guidewire exchange is safe alternative to catheter removal with delayed reinsertion
    Mokrzycki, MH
    Zhang, ML
    Cohen, H
    Laut, J
    D'Avella, J
    Rosenberg, SO
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2003, 14 : 241A - 241A
  • [24] Catheter failure and mortality in hemodialysis patients with the tunneled-cuffed catheter tip positioned in the inferior vena cava
    Cheng Lu
    Ren Qian
    Yu Gang
    Gou Shenju
    Cui Tianlei
    Fu Ping
    中华医学杂志英文版, 2022, 135 (19)
  • [25] Changes to indications for tunneled cuffed catheter use in hemodialysis patients: A single-center experience
    Okamoto, Takeshi
    Sakurada, Tsutomu
    Koitabashi, Kenichiro
    Shibagaki, Yugo
    HEMODIALYSIS INTERNATIONAL, 2018, 22 : S3 - S9
  • [26] Management of tunneled-cuffed catheter-related right atrial thrombosis in hemodialysis patients
    Yang, Hongliu
    Chen, Feng
    Jiao, He
    Luo, Han
    Yu, Yang
    Hong, Hyokyoung G.
    Li, Yi
    Fu, Ping
    Cui, Tianlei
    JOURNAL OF VASCULAR SURGERY, 2018, 68 (05) : 1491 - 1498
  • [27] Regarding "Management of tunneled-cuffed catheter-related right atrial thrombosis in hemodialysis patients"
    Ghannam, Jacob S.
    Srinivasa, Ravi N.
    Chick, Jeffrey Forris Beecham
    JOURNAL OF VASCULAR SURGERY, 2019, 69 (01) : 311 - 312
  • [28] Hemodialysis tunneled-cuffed catheter-related atrial thrombus complicated with asymptomatic pulmonary emboli
    Zhang, Zhoucang
    Zhang, Dongliang
    JOURNAL OF VASCULAR ACCESS, 2018, 19 (02): : 197 - 198
  • [29] Tunneled-cuffed catheter associated infections in hemodialysis patients who are seropositive for the human immunodeficiency virus
    Mokrzycki, MH
    Schröppel, B
    von Gersdorff, G
    Rush, H
    Zdunek, MP
    Feingold, R
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2000, 11 (11): : 2122 - 2127
  • [30] INCIDENCE OF TUNNELED CUFFED VASCULAR CATHETERS INFECTION IN DIABETICS ON HEMODIALYSIS
    Bajcetic, Sanja
    Jankovic, Aleksandar
    Djuric, Petar
    Popovic, Jovan
    Dimkovic, Nada
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2017, 32